246,658 research outputs found

    A viscoelastic traction layer model of mucociliary flow

    Get PDF
    A new mathematical model of the transport of mucus and periciliary liquid (PCL) in the airways by cilia is presented. Mucus is represented by a linearly viscoelastic fluid, the mat of cilia is modelled as an ‘active porous medium.’ The propulsive effect of the cilia is modelled by a time-dependent force acting in a shear-thinned ‘traction layer’ between the mucus and the PCL. The effects of surface and interface tension are modelled by constraining the mucus free surface and mucus–PCL interface to be flat. It is assumed that the epithelium is impermeable to fluid. Using Fourier series, the system is converted into ODEs and solved numerically. We calculate values for mean mucus speed close to those observed by Matsui et~al. [{J. Clin. Invest.}, 102(6):1125’1131, 1998], (~40 ÎŒms−1). We obtain more detail regarding the dynamics of the flow and the nonlinear relationships between physical parameters in healthy and diseased states than in previously published models. Pressure gradients in the PCL caused by interface and surface tension are vital to ensuring efficient transport of mucus, and the role of the mucus–PCL interface appears to be to support such pressure gradients, ensuring efficient transport. Mean transport of PCL is found to be very small, consistent with previous analyses, providing insight into theories regarding the normal tonicity of PCL

    Fluid mechanics of nodal flow due to embryonic primary cilia

    Get PDF
    Breaking of left–right symmetry is crucial in vertebrate development. The role of cilia-driven flow has been the subject of many recent publications, but the underlying mechanisms remain controversial. At approximately 8 days post-fertilization, after the establishment of the dorsal–ventral and anterior–posterior axes, a depressed structure is found on the ventral side of mouse embryos, termed the ventral node. Within the node, ‘whirling’ primary cilia, tilted towards the posterior, drive a flow implicated in the initial left–right signalling asymmetry. However, the underlying fluid mechanics have not been fully and correctly explained until recently and accurate characterization is required in determining how the flow triggers the downstream signalling cascades. Using the approximation of resistive force theory, we show how the flow is produced and calculate the optimal configuration to cause maximum flow, showing excellent agreement with in vitro measurements and numerical simulation, and paralleling recent analogue experiments. By calculating numerical solutions of the slender body theory equations, we present time-dependent physically based fluid dynamics simulations of particle pathlines in flows generated by large arrays of beating cilia, showing the far-field radial streamlines predicted by the theory

    Space shuttle orbiter reusable surface insulation flight results

    Get PDF
    The first five flights of the orbiter Columbia provided the initial data required to certify the operational performance of the reusable surface insulation (RSI) thermal protection system (TPS). The flight performance characteristics of the RIS TPS are discussed. The discussion is based primarily on postflight inspections and postflight interpretation of the flight instrumentation. TPS modifications of the future orbiters (OV-099, 103, and subs) are also discussed

    Mathematical modelling of cilia driven transport of biological fluids

    Get PDF
    Cilia-driven flow occurs in the airway surface liquid, in the female and male reproductive tracts and enables symmetry-breaking in the embryonic node. Viscoelastic rheology is found in healthy states in some systems, whereas in others may characterise disease, motivating the development of mathematical models that take this effect into account. We derive the fundamental solution for linear viscoelastic flow, which is subsequently used as a basis for slender-body theory. Our numerical algorithm allows efficient computation of three-dimensional time-dependent flow, bending moments, power and particle transport. We apply the model to the large-amplitude motion of a single cilium in a linear Maxwell liquid. A relatively short relaxation time of just 0.032 times the beat period significantly reduces forces, bending moments, power and particle transport, the last variable exhibiting exponential decay with relaxation time. A test particle is propelled approximately one-fifth as quickly along the direction of cilia beating for scaled relaxation time 0.032 as in the Newtonian case, and mean volume flow is abolished, emphasizing the sensitivity of cilia function to fluid rheology. These results may have implications for flow in the airways, where the transition from Newtonian to viscoelastic rheology in the peri-ciliary fluid may reduce clearance

    Tensile properties of palladium-silver alloys with absorbed hydrogen

    Get PDF
    The alloys 90Pd-10Ag, 80Pd-20Ag, 70Pd-30Ag, 60Pd-40Ag, and 50Pd-50Ag containing absorbed hydrogen were tested in tension. The results show the tensile properties to be independent of the phase transition. Also, hydrogen in the lattice does not necessarily cause embrittlement or poor elongation. The changes in the tensile properties appear dependent on the electron to atom site ratio

    Analytical study of catalytic reactors for hydrazine decomposition. One and two dimensional steady-state programs, computer programs manual

    Get PDF
    Programs manual for one-dimensional and two- dimensional steady state models of catalyzed hydrazine decomposition reaction chamber

    Multichannel operation of an integrated acousto-optic wavelength routing switch for WDM systems

    Get PDF
    Polarization independent acousto-optic tunable filters (PIAOTF's) can operate as transparent wavelength-selective crossconnects to route signals in wavelength division multiplexed optical networks. In this paper, a new low power PIAOTF is characterized as a switch in multiwavelength operation, using four equally spaced lightwave signals with wavelengths between 1546 nm and 1558 nm. Interchannel interference due to sidelobe excitation is lower than -11 dB for single wavelength switching and is equal to -6 dB in the extreme case of simultaneous switching of all wavelength channels. Sources of interport and interchannel crosstalk for single and multiple wavelength switching are identified

    Color and texture associations in voice-induced synesthesia

    Get PDF
    Voice-induced synesthesia, a form of synesthesia in which synesthetic perceptions are induced by the sounds of people's voices, appears to be relatively rare and has not been systematically studied. In this study we investigated the synesthetic color and visual texture perceptions experienced in response to different types of “voice quality” (e.g., nasal, whisper, falsetto). Experiences of three different groups—self-reported voice synesthetes, phoneticians, and controls—were compared using both qualitative and quantitative analysis in a study conducted online. Whilst, in the qualitative analysis, synesthetes used more color and texture terms to describe voices than either phoneticians or controls, only weak differences, and many similarities, between groups were found in the quantitative analysis. Notable consistent results between groups were the matching of higher speech fundamental frequencies with lighter and redder colors, the matching of “whispery” voices with smoke-like textures, and the matching of “harsh” and “creaky” voices with textures resembling dry cracked soil. These data are discussed in the light of current thinking about definitions and categorizations of synesthesia, especially in cases where individuals apparently have a range of different synesthetic inducers

    Mathematical and computer modeling of electro-optic systems using a generic modeling approach

    Get PDF
    The conventional approach to modelling electro-optic sensor systems is to develop separate models for individual systems or classes of system, depending on the detector technology employed in the sensor and the application. However, this ignores commonality in design and in components of these systems. A generic approach is presented for modelling a variety of sensor systems operating in the infrared waveband that also allows systems to be modelled with different levels of detail and at different stages of the product lifecycle. The provision of different model types (parametric and image-flow descriptions) within the generic framework can allow valuable insights to be gained
    • 

    corecore