4,385 research outputs found

    Sample Testing with Vitalab Flexor

    Get PDF
    The Vitalab Flexor is a high-tech medical instrument designed to perform a large number of simultaneous measurements on samples of blood and urine. For future purposes it is desired to increase the throughput, i.e. the number of tests per hour, of the instrument. The analysis in this report gives upper bounds on the throughput if the Vitalab Flexor is operated in modes which are standard in the present situation. It is shown that a desired throughput of at least 266 tests per hour can not be realized on the basis of these standard operation modes. Possible improvements are suggested via so-called parallel or on-line operation modes, or a combination of these two modes. These possible improvements however require a number of changes in the technical design of the Vitalab Flexor

    Hydrodynamics in a cocurrent gas-liquid trickle bed at elevated pressures

    Get PDF
    Data on design and operation of trickle beds at elevated pressures are scarce. In this study the influence of the gas density on the liquid holdup, the pressure drop, and the transition between trickle and pulse flow has been investigated in a tricklebed reactor operating up to 7.5 MPa and with nitrogen or helium as the gas phase. Gas-liquid interfacial areas have been determined up to 5.0 MPa by means of CO2 absorption from CO2/N2 gas mixtures into amine solutions. \ud A comparison of the results from nitrogen as the gas phase to those of helium shows that at equal gas densities the hydrodynamic states are the same. The gas-liquid interfacial area increases when operating at higher gas densities. When the determined dimensionless interfacial areas agl/as are all within the range 0.25-0.8, the trickle-bed reactor is suggested to operate in the trickle-flow regime. The gas density has a strong influence on the liquid holdup. Due to the higher pressure gradients at elevated gas densities, the liquid holdup decreases noticeably. Besides, the boundary between the trickle-flow and pulse-flow regime shifts toward higher liquid throughputs: the region for trickle-flow operationg becomes larger. For the liquid holdup and the pressure gradient in the trickle-flow regime, correlations derived based on dimensionless numbers can be applied to high-prssure trickle beds

    Detection of Neutral Carbon in the M 31 Dark Cloud D478

    Get PDF
    Emission from the 492 GHz CI tranition was detected towards the dark cloud D478 in M31. Using existing 12CO and 13CO measurements, models for the gas properties of D478 are discussed. The observed CO and C line ratios can be explained by two-component models (dense cores and tenuous envelopes); single-density models appear less likely. The models indicate temperatures T(kin) = 10 K. The beam-averaged C column density is 0.3 - 0.8 times that of CO, whereas the total carbon to hydrogen ratio N(C)/N(H) = 5-3 times 10**-4. The resulting CO-to-H2 conversion factor X is about half that of the Solar Neighbourhood. With temperatures of about 10 K and projected mass densities of 5-10 M(sun)/pc**2 there appears to be no need to invoke the presence of very cold and very massive clouds. Rather, D478 appears to be comparable to Milky Way dark cloud complexes such as the Taurus-Auriga dark cloud complex.Comment: 7 Pages, 1 Figure; accepted by A&
    corecore