1,371 research outputs found

    Beam losses from ultra-peripheral nuclear collisions between Pb ions in the Large Hadron Collider and their alleviation

    Get PDF
    Electromagnetic interactions between colliding heavy ions at the Large Hadron Collider (LHC) at CERN will give rise to localized beam losses that may quench superconducting magnets, apart from contributing significantly to the luminosity decay. To quantify their impact on the operation of the collider, we have used a three-step simulation approach, which consists of optical tracking, a Monte-Carlo shower simulation and a thermal network model of the heat flow inside a magnet. We present simulation results for the case of Pb ion operation in the LHC, with focus on the ALICE interaction region, and show that the expected heat load during nominal Pb operation is 40% above the quench level. This limits the maximum achievable luminosity. Furthermore, we discuss methods of monitoring the losses and possible ways to alleviate their effect.Comment: 17 pages, 20 figure

    Initial evidence for the criterion-related and structural validity of the long versions of the direct and meta-perspectives of the Coach-Athlete Relationship Questionnaire

    Get PDF
    This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2010 Taylor & Francis.The aim of the present study was to develop and initially validate a longer version of the direct (Jowett & Ntoumanis, 2004) and meta-perspectives (Jowett, 2009a, 2009b) of the Coach-Athlete Relationship Questionnaire (CART-Q). In Study 1, instruments (e.g. questionnaires, scales, and inventories) that have been used to assess relationship quality in the broader psychological literature were examined and items potentially relevant to the coach-athlete relationship were identified. The content validity of the identified items was then assessed using expert panels. A final questionnaire was subsequently prepared and administered to 693 participants (310 coaches and 383 athletes). Confirmatory factor analysis was employed to assess the multidimensional nature of the questionnaire based on the 3Cs (i.e. closeness, commitment, and complementarity) model of the coach-athlete relationship. The findings indicated that the direct and meta-perspective items of the long versions of the CART-Q approached an adequate data fit. Moreover, evidence for the internal consistency and criterion validity of the new instruments was also obtained. In Study 2, the newly developed measure was administered to an independent sample of 251 individuals (145 athletes and 106 coaches). Further statistical support was gained for the factorial validity and reliability of the longer version of the CART-Q

    Physics Opportunities with the FCC-hh Injectors

    Get PDF
    In this chapter we explore a few examples of physics opportunities using the existing chain of accelerators at CERN, including potential upgrades. In this context the LHC ring is also considered as a part of the injector system. The objective is to find examples that constitute sensitive probes of New Physics that ideally cannot be done elsewhere or can be done significantly better at theCERN accelerator complex. Some of these physics opportunities may require a more flexible injector complex with additional functionality than that just needed to inject protons into the FCC-hh at the right energy, intensity and bunch structure. Therefore it is timely to discuss these options concurrently with the conceptual design of the FCC-hh injector system.Comment: 13 pages, chapter 5 in Physics at the FCC-hh, a 100 TeV pp collide

    Measurements of heavy ion beam losses from collimation

    Get PDF
    The collimation efficiency for Pb ion beams in the LHC is predicted to be lower than requirements. Nuclear fragmentation and electromagnetic dissociation in the primary collimators create fragments with a wide range of Z/A ratios, which are not intercepted by the secondary collimators but lost where the dispersion has grown sufficiently large. In this article we present measurements and simulations of loss patterns generated by a prototype LHC collimator in the CERN SPS. Measurements were performed at two different energies and angles of the collimator. We also compare with proton loss maps and find a qualitative difference between Pb ions and protons, with the maximum loss rate observed at different places in the ring. This behavior was predicted by simulations and provides a valuable benchmark of our understanding of ion beam losses caused by collimation.Comment: 12 pages, 20 figure

    Design of beam optics for the Future Circular Collider e+e- -collider rings

    Full text link
    A beam optics scheme has been designed for the Future Circular Collider-e+e- (FCC-ee). The main characteristics of the design are: beam energy 45 to 175 GeV, 100 km circumference with two interaction points (IPs) per ring, horizontal crossing angle of 30 mrad at the IP and the crab-waist scheme [1] with local chromaticity correction. The crab-waist scheme is implemented within the local chromaticity correction system without additional sextupoles, by reducing the strength of one of the two sextupoles for vertical chromatic correction at each side of the IP. So-called "tapering" of the magnets is applied, which scales all fields of the magnets according to the local beam energy to compensate for the effect of synchrotron radiation (SR) loss along the ring. An asymmetric layout near the interaction region reduces the critical energy of SR photons on the incoming side of the IP to values below 100 keV, while matching the geometry to the beam line of the FCC proton collider (FCC-hh) [2] as closely as possible. Sufficient transverse/longitudinal dynamic aperture (DA) has been obtained, including major dynamical effects, to assure an adequate beam lifetime in the presence of beamstrahlung and top-up injection. In particular, a momentum acceptance larger than +/-2% has been obtained, which is better than the momentum acceptance of typical collider rings by about a factor of 2. The effects of the detector solenoids including their compensation elements are taken into account as well as synchrotron radiation in all magnets. The optics presented in this paper is a step toward a full conceptual design for the collider. A number of issues have been identified for further study

    Keele Aches and Pains Study Protocol: validity, acceptability and feasibility of the Keele STarT MSK Tool for subgrouping musculoskeletal patients in primary care

    Get PDF
    Musculoskeletal conditions represent a considerable burden worldwide, and are predominantly managed in primary care. Evidence suggests that many musculoskeletal conditions share similar prognostic factors. Systematically assessing patient’s prognosis, and matching treatments based on prognostic subgroups (stratified care), has been shown to be clinically and cost effective. This study (Keele Aches and Pains Study: KAPS) aims to refine and examine the validity of a brief questionnaire (Keele STarT MSK Tool), designed to enable risk-stratification of primary care patients with the five most common musculoskeletal pain presentations. We will also describe the subgroups of patients, and explore the acceptability and feasibility of using the tool, and how the tool is best implemented in clinical practice. The study design is mixed methods: a prospective, quantitative observational cohort study with a linked qualitative focus group and interview study. Patients who have consulted their General Practitioner or Healthcare Practitioner (GP/HCP) about a relevant musculoskeletal condition will be recruited from General practice. Participating patients will complete a baseline questionnaire (shortly after consultation), plus questionnaires 2 and 6 months later. A sub-sample of patients, along with participating GPs and HCPs, will be invited to take part in qualitative focus groups and interviews. The Keele STarT MSK Tool will be refined based on face, discriminant, construct and predictive validity at baseline and 2 months, and validated using data from 6 month follow-up. Patient and clinician perspectives about using the tool will be explored. This study will provide a validated prognostic tool (the Keele STarT MSK Tool) with established cut-points to stratify patients with the five most common musculoskeletal presentations into low, medium and high risk subgroups. The qualitative analysis of patient and healthcare perspectives will inform how to embed the tool into clinical practice using established general practice IT systems and clinician support packages

    A Storage Ring based Option for the LHeC

    Get PDF
    The LHeC aims at the generation of hadron-lepton collisions with center of mass energies in the TeV scale and luminosities of the order of 10321033cm2sec110^{32}-10^{33} cm^{-2} sec^{-1} by taking advantage of the existing LHC 7 TeV proton ring and adding a high energy electron accelerator. This paper presents technical considerations and potential parameter choices for such a machine and outlines some of the challenges arising when an electron storage ring based option, constructed within the existing infrastructure of the LHC, is chosen

    Evolutionary Toggling of Vpx/Vpr Specificity Results in Divergent Recognition of the Restriction Factor SAMHD1

    Get PDF
    SAMHD1 is a host restriction factor that blocks the ability of lentiviruses such as HIV-1 to undergo reverse transcription in myeloid cells and resting T-cells. This restriction is alleviated by expression of the lentiviral accessory proteins Vpx and Vpr (Vpx/Vpr), which target SAMHD1 for proteasome-mediated degradation. However, the precise determinants within SAMHD1 for recognition by Vpx/Vpr remain unclear. Here we show that evolution of Vpx/Vpr in primate lentiviruses has caused the interface between SAMHD1 and Vpx/Vpr to alter during primate lentiviral evolution. Using multiple HIV-2 and SIV Vpx proteins, we show that Vpx from the HIV-2 and SIVmac lineage, but not Vpx from the SIVmnd2 and SIVrcm lineage, require the C-terminus of SAMHD1 for interaction, ubiquitylation, and degradation. On the other hand, the N-terminus of SAMHD1 governs interactions with Vpx from SIVmnd2 and SIVrcm, but has little effect on Vpx from HIV-2 and SIVmac. Furthermore, we show here that this difference in SAMHD1 recognition is evolutionarily dynamic, with the importance of the N- and C-terminus for interaction of SAMHD1 with Vpx and Vpr toggling during lentiviral evolution. We present a model to explain how the head-to-tail conformation of SAMHD1 proteins favors toggling of the interaction sites by Vpx/Vpr during this virus-host arms race. Such drastic functional divergence within a lentiviral protein highlights a novel plasticity in the evolutionary dynamics of viral antagonists for restriction factors during lentiviral adaptation to its hosts. © 2013 Fregoso et al
    corecore