140 research outputs found

    Fluid lavage in patients with open fracture wounds (FLOW): an international survey of 984 surgeons

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although surgeons acknowledge the importance of irrigating open fracture wounds, the choice of irrigating fluid and delivery pressure remains controversial. Our objective was to clarify current opinion with regard to the irrigation of open fracture wounds.</p> <p>Methods</p> <p>We used a cross-sectional survey and a sample-to-redundancy strategy to examine surgeons' preferences in the initial management of open fracture wounds. We mailed this survey to members of the Canadian Orthopaedic Association and delivered it to attendees of an international fracture course (AO, Davos, Switzerland).</p> <p>Results</p> <p>Of the 1,764 surgeons who received the questionnaire, 984 (55.8%) responded. In the management of open wounds, the majority of surgeons surveyed, 676 (70.5%), favoured normal saline alone. Bacitracin solution was used routinely by only 161 surgeons (16.8%). The majority of surgeons, 695 (71%) used low pressures when delivering the irrigating solution to the wound. There was, however considerable variation in what pressures constituted high versus low pressure lavage. The overwhelming majority of surgeons, 889 (94.2%), reported they would change their practice if a large randomized controlled trial showed a clear benefit of an irrigating solution – especially if it was different from the solution they used.</p> <p>Conclusion</p> <p>The majority of surgeons favour both normal saline and low pressure lavage for the initial management of open fracture wounds. However, opinions varied as regards the comparative efficacy of different solutions, the use of additives and high versus low pressure. Surgeons have expressed considerable support for a trial evaluating both irrigating solutions and pressures.</p

    A Trial of Wound Irrigation in the Initial Management of Open Fracture Wounds

    Get PDF
    Copyright © 2015 Massachusetts Medical Society. BACKGROUND The management of open fractures requires wound irrigation and dridement to remove contaminants, but the effectiveness of various pressures and solutions for irrigation remains controversial. We investigated the effects of castile soap versus normal saline irrigation delivered by means of high, low, or very low irrigation pressure. METHODS In this study with a 2-by-3 factorial design, conducted at 41 clinical centers, we randomly assigned patients who had an open fracture of an extremity to undergo irrigation with one of three irrigation pressures (high pressure [\u3e20 psi], low pressure [5 to 10 psi], or very low pressure [1 to 2 psi]) and one of two irrigation solutions (castile soap or normal saline). The primary end point was reoperation within 12 months after the index surgery for promotion of wound or bone healing or treatment of a wound infection. RESULTS A total of 2551 patients underwent randomization, of whom 2447 were deemed eligible and included in the final analyses. Reoperation occurred in 109 of 826 patients (13.2%) in the high-pressure group, 103 of 809 (12.7%) in the low-pressure group, and 111 of 812 (13.7%) in the very-low-pressure group. Hazard ratios for the three pairwise comparisons were as follows: for low versus high pressure, 0.92 (95% confidence interval [CI], 0.70 to 1.20; P = 0.53), for high versus very low pressure, 1.02 (95% CI, 0.78 to 1.33; P = 0.89), and for low versus very low pressure, 0.93 (95% CI, 0.71 to 1.23; P = 0.62). Reoperation occurred in 182 of 1229 patients (14.8%) in the soap group and in 141 of 1218 (11.6%) in the saline group (hazard ratio, 1.32, 95% CI, 1.06 to 1.66; P = 0.01). CONCLUSIONS The rates of reoperation were similar regardless of irrigation pressure, a finding that indicates that very low pressure is an acceptable, low-cost alternative for the irrigation of open fractures. The reoperation rate was higher in the soap group than in the saline group. (Funded by the Canadian Institutes of Health Research and others; FLOW ClinicalTrials.gov number, NCT00788398

    Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the face of costly fixation hardware with varying performance for treatment of distal humeral fractures, a novel technique (U-Frame) is proposed using conventional implants in a 180° plate arrangement. In this in-vitro study the biomechanical stability of this method was compared with the established technique which utilizes angular stable locking compression plates (LCP) in a 90° configuration.</p> <p>Methods</p> <p>An unstable distal 3-part fracture (AO 13-C2.3) was created in eight pairs of human cadaveric humeri. All bone pairs were operated with either the "Frame" technique, where two parallel plates are distally interconnected, or with the LCP technique. The specimens were cyclically loaded in simulated flexion and extension of the arm until failure of the construct occurred. Motion of all fragments was tracked by means of optical motion capturing. Construct stiffness and cycles to failure were identified for all specimens.</p> <p>Results</p> <p>Compared to the LCP constructs, the "Frame" technique revealed significant higher construct stiffness in extension of the arm (P = 0.01). The stiffness in flexion was not significantly different (P = 0.16). Number of cycles to failure was found significantly larger for the "Frame" technique (P = 0.01).</p> <p>Conclusions</p> <p>In an in-vitro context the proposed method offers enhanced biomechanical stability and at the same time significantly reduces implant costs.</p

    Risk Factors Associated With Infection in Open Fractures of the Upper and Lower Extremities

    Get PDF
    Introduction: Open fractures are associated with a high risk of infection. The prevention of infection is the single most important goal, influencing perioperative care of patients with open fractures. Using data from 2,500 participants with open fracture wounds enrolled in the Fluid Lavage of Open Wounds trial, we conducted a multivariable analysis to determine the factors that are associated with infections 12 months postfracture. Methods: Eighteen predictor variables were identified for infection a priori from baseline data, fracture characteristics, and surgical data from the Fluid Lavage of Open Wounds trial. Twelve predictor variables were identified for deep infection, which included both surgically and nonoperatively managed infections.We used multivariable Cox proportional hazards regression analyses to identify the factors associated with infection. Irrigation solution and pressure were included as variables in the analysis. The results were reported as adjusted hazard ratios (HRs), 95% confidence intervals (CIs), and associated P values. All tests were two tailed with alpha = 0.05. Results: Factors associated with any infection were fracture location (tibia: HR 5.13 versus upper extremity, 95% CI 3.28 to 8.02; other lower extremity: HR 3.63 versus upper extremity, 95% CI 2.38 to 5.55; overall P\u3c 0.001), low energy injury (HR 1.64, 95% CI 1.08 to 2.46; P = 0.019), degree of wound contamination (severe: HR 2.12 versus mild, 95% CI 1.35 to 3.32; moderate: HR 1.08 versus mild, 95% CI 0.78 to 1.49; overall P = 0.004), and need for flap coverage (HR 1.82, 95% CI 1.11 to 2.99; P = 0.017). Discussion: The results of this study provide a better understanding of which factors are associated with a greater risk of infection in open fractures. In addition, it can allow for surgeons to better counsel patients regarding prognosis, helping patients to understand their individual risk of infection

    Risk Factors Associated With Infection in Open Fractures of the Upper and Lower Extremities

    Get PDF
    Introduction: Open fractures are associated with a high risk of infection. The prevention of infection is the single most important goal, influencing perioperative care of patients with open fractures. Using data from 2,500 participants with open fracture wounds enrolled in the Fluid Lavage of Open Wounds trial, we conducted a multivariable analysis to determine the factors that are associated with infections 12 months postfracture. Methods: Eighteen predictor variables were identified for infection a priori from baseline data, fracture characteristics, and surgical data from the Fluid Lavage of Open Wounds trial. Twelve predictor variables were identified for deep infection, which included both surgically and nonoperatively managed infections.We used multivariable Cox proportional hazards regression analyses to identify the factors associated with infection. Irrigation solution and pressure were included as variables in the analysis. The results were reported as adjusted hazard ratios (HRs), 95% confidence intervals (CIs), and associated P values. All tests were two tailed with alpha = 0.05. Results: Factors associated with any infection were fracture location (tibia: HR 5.13 versus upper extremity, 95% CI 3.28 to 8.02; other lower extremity: HR 3.63 versus upper extremity, 95% CI 2.38 to 5.55; overall P\u3c 0.001), low energy injury (HR 1.64, 95% CI 1.08 to 2.46; P = 0.019), degree of wound contamination (severe: HR 2.12 versus mild, 95% CI 1.35 to 3.32; moderate: HR 1.08 versus mild, 95% CI 0.78 to 1.49; overall P = 0.004), and need for flap coverage (HR 1.82, 95% CI 1.11 to 2.99; P = 0.017). Discussion: The results of this study provide a better understanding of which factors are associated with a greater risk of infection in open fractures. In addition, it can allow for surgeons to better counsel patients regarding prognosis, helping patients to understand their individual risk of infection

    Are large clinical trials in orthopaedic trauma justified?

    Get PDF
    © 2018 The Author(s). Background: The objective of this analysis is to evaluate the necessity of large clinical trials using FLOW trial data. Methods: The FLOW pilot study and definitive trial were factorial trials evaluating the effect of different irrigation solutions and pressures on re-operation. To explore treatment effects over time, we analyzed data from the pilot and definitive trial in increments of 250 patients until the final sample size of 2447 patients was reached. At each increment we calculated the relative risk (RR) and associated 95% confidence interval (CI) for the treatment effect, and compared the results that would have been reported at the smaller enrolments with those seen in the final, adequately powered study. Results: The pilot study analysis of 89 patients and initial incremental enrolments in the FLOW definitive trial favored low pressure compared to high pressure (RR: 1.50, 95% CI: 0.75-3.04; RR: 1.39, 95% CI: 0.60-3.23, respectively), which is in contradiction to the final enrolment, which found no difference between high and low pressure (RR: 1.04, 95% CI: 0.81-1.33). In the soap versus saline comparison, the FLOW pilot study suggested that re-operation rate was similar in both the soap and saline groups (RR: 0.98, 95% CI: 0.50-1.92), whereas the FLOW definitive trial found that the re-operation rate was higher in the soap treatment arm (RR: 1.28, 95% CI: 1.04-1.57). Conclusions: Our findings suggest that studies with smaller sample sizes would have led to erroneous conclusions in the management of open fracture wounds. Trial registration: NCT01069315 (FLOW Pilot Study) Date of Registration: February 17, 2010, NCT00788398 (FLOW Definitive Trial) Date of Registration: November 10, 2008

    Effects of low intensity pulsed ultrasound with and without increased cortical porosity on structural bone allograft incorporation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Though used for over a century, structural bone allografts suffer from a high rate of mechanical failure due to limited graft revitalization even after extended periods <it>in vivo</it>. Novel strategies that aim to improve graft incorporation are lacking but necessary to improve the long-term clinical outcome of patients receiving bone allografts. The current study evaluated the effect of low-intensity pulsed ultrasound (LIPUS), a potent exogenous biophysical stimulus used clinically to accelerate the course of fresh fracture healing, and longitudinal allograft perforations (LAP) as non-invasive therapies to improve revitalization of intercalary allografts in a sheep model.</p> <p>Methods</p> <p>Fifteen skeletally-mature ewes were assigned to five experimental groups based on allograft type and treatment: +CTL, -CTL, LIPUS, LAP, LIPUS+LAP. The +CTL animals (n = 3) received a tibial ostectomy with immediate replacement of the resected autologous graft. The -CTL group (n = 3) received fresh frozen ovine tibial allografts. The +CTL and -CTL groups did not receive LAP or LIPUS treatments. The LIPUS treatment group (n = 3), following grafting with fresh frozen ovine tibial allografts, received ultrasound stimulation for 20 minutes/day, 5 days/week, for the duration of the healing period. The LAP treatment group (n = 3) received fresh frozen ovine allografts with 500 μm longitudinal perforations that extended 10 mm into the graft. The LIPUS+LAP treatment group (n = 3) received both LIPUS and LAP interventions. All animals were humanely euthanized four months following graft transplantation for biomechanical and histological analysis.</p> <p>Results</p> <p>After four months of healing, daily LIPUS stimulation of the host-allograft junctions, alone or in combination with LAP, resulted in 30% increases in reconstruction stiffness, paralleled by significant increases (p < 0.001) in callus maturity and periosteal bridging across the host/allograft interfaces. Longitudinal perforations extending 10 mm into the proximal and distal endplates filled to varying degrees with new appositional bone and significantly accelerated revitalization of the allografts compared to controls.</p> <p>Conclusion</p> <p>The current study has demonstrated in a large animal model the potential of both LIPUS and LAP therapy to improve the degree of allograft incorporation. LAP may provide an option for increasing porosity, and thus potential <it>in vivo </it>osseous apposition and revitalization, without adversely affecting the structural integrity of the graft.</p

    3066 consecutive Gamma Nails. 12 years experience at a single centre

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Fixation of trochanteric hip fractures using the Gamma Nail has been performed since 1988 and is today well established and wide-spread. However, a number of reports have raised serious concerns about the implant's complication rate. The main focus has been the increased risk of a subsequent femoral shaft fracture and some authors have argued against its use despite other obvious advantages, when this implant is employed.</p> <p>Through access to a uniquely large patient data base available, which is available for analysis of trochanteric fractures; we have been able to evaluate the performance of the Gamma Nail over a twelve year period.</p> <p>Methods</p> <p>3066 consecutive patients were treated for trochanteric fractures using Gamma Nails between 1990 and 2002 at the Centre de Traumatologie et de l'Orthopedie (CTO), Strasbourg, France. These patients were retrospectively analysed. Information on epidemiological data, intra- and postoperative complications and patients' outcome was retrieved from patient notes. All available radiographs were assessed by a single reviewer (AJB).</p> <p>Results</p> <p>The results showed a low complication rate with the use of the Gamma Nail. There were 137 (4.5%) intraoperative fracture-related complications. Moreover 189 (6.2%) complications were detected postoperatively and during follow-up. Cut-out of the lag screw from the femoral head was the most frequent mechanical complication (57 patients, 1.85%), whereas a postoperative femoral shaft fracture occurred in 19 patients (0.6%). Other complications, such as infection, delayed healing/non-union, avascular femoral head necrosis and distal locking problems occurred in 113 patients (3.7%).</p> <p>Conclusions</p> <p>The use of the Gamma Nail in trochanteric hip fractures is a safe method with a low complication rate. In particular, a low rate of femoral shaft fractures was reported. The low complication rate reported in this series can probably be explained by strict adherence to a proper surgical technique.</p
    corecore