21,841 research outputs found
Warp evidences in precessing galactic bar models
Most galaxies have a warped shape when they are seen from an edge-on point of
view. The reason for this curious form is not completely known so far and in
this work we apply dynamical system tools to contribute to its explanation.
Starting from a simple, but realistic, model formed by a bar and a disc, we
study the effect produced by a small misalignment between the angular momentum
of the system and its angular velocity. To this end, a precession model is
developed and considered, assuming that the bar behaves like a rigid body.
After checking that the periodic orbits inside the bar keep being the skeleton
of the inner system, even after inflicting a precession to the potential, we
compute the invariant manifolds of the unstable periodic orbits departing from
the equilibrium points at the ends of the bar to get evidences of their warped
shapes. As it is well known, the invariant manifolds associated with these
periodic orbits drive the arms and rings of barred galaxies and constitute the
skeleton of these building blocks. Looking at them from a side-on viewpoint, we
find that these manifolds present warped shapes as those recognized in
observations. Lastly, test particle simulations have been performed to
determine how the stars are affected by the applied precession, confirming this
way the theoretical results obtained.Comment: 14 pages, 21 figures, Accepted for publication in A&A (15th Jan 2016
A pilot search for mm-wavelength recombination lines from emerging ionized winds in pre-planetary nebulae candidates
We report the results from a pilot search for radio recombination line (RRL)
emission at millimeter wavelengths in a small sample of pre-planetary nebulae
(pPNe) and young PNe (yPNe) with emerging central ionized regions. Observations
of the H30\alpha, H31a, H39a, H41a, H48b, H49b, H51b, and H55g lines at 1 and
3mm have been performed with the IRAM 30 m radio telescope. These lines are
excellent probes of the dense inner (<~150 au) and heavily obscured regions of
these objects, where the yet unknown agents for PN-shaping originate. We
detected mm-RRLs in three objects: CRL 618, MWC 922, and M 2-9. For CRL 618,
the only pPN with previous published detections of H41a, H35a, and H30a
emission, we find significant changes in the line profiles indicating that
current observations are probing regions of the ionized wind with larger
expansion velocities and mass-loss rate than ~29 years ago. In the case of MWC
922, we observe a drastic transition from single-peaked profiles at 3mm to
double-peaked profiles at 1mm, which is consistent with maser amplification of
the highest frequency lines; the observed line profiles are compatible with
rotation and expansion of the ionized gas, probably arranged in a disk+wind
system around a ~5-10 Msun central mass. In M 2-9, the mm-RRL emission appears
to be tracing a recent mass outburst by one of the stars of the central binary
system. We present the results from non-LTE line and continuum radiative
transfer models, which enables us to constrain the structure, kinematics, and
physical conditions (electron temperature and density) of the ionized cores of
our sample. (abridged). We deduce mass-loss rates of ~1e-6-1e-7 Msun/yr, which
are significantly higher than the values adopted by stellar evolution models
currently in use and would result in a transition from the asymptotic giant
branch to the PN phase faster than hitherto assumed.Comment: Accepted by Astronomy and Astrophysics. 28 pages, including figure
An Example of Climate-relevant Processes Unresolved by Present-day General Circulation Models
Reversible enhancement of the magnetism of ultrathin Co films by H adsorption
By means of ab initio calculations, we have investigated the effect of H
adsorption in the structural, electronic and magnetic properties of ultrathin
Co films on Ru(0001). Our calculations predict that H occupies hollow sites
preserving the two-dimensional 3-fold symmetry. The formation of a complete H
overlayer leads to a very stable surface with strong H-Co bonds. H tends to
suppress surface features, in particular, the enhancement of the magnetic
moments of the bare film. The H-induced effects are mostly confined to the Co
atoms bonded to H, independent of the H coverage or of the thickness and the
structure of the Co film. However, for partial H coverages a significant
increase occurs in the magnetic moment for the surface Co atoms not bonded to
H, leading to a net enhancement of surface magnetism.Comment: 6 pages, 4 figures, 3 table
Interplay between the magnetic anisotropy contributions of Cobalt nanowires
We report on the magnetic properties and the crystallographic structure of
the cobalt nanowire arrays as a function of their nanoscale dimensions. X-ray
diffraction measurements show the appearance of an in-plane HCP-Co phase for
nanowires with 50 nm diameter, suggesting a partial reorientation of the
magnetocrystalline anisotropy axis along the membrane plane with increasing
pore diameter. No significant changes in the magnetic behavior of the nanowire
system are observed with decreasing temperature, indicating that the effective
magnetoelastic anisotropy does not play a dominant role in the remagnetization
processes of individual nanowires. An enhancement of the total magnetic
anisotropy is found at room temperature with a decreasing nanowire
diameter-to-length ratio (d/L), a result that is quantitatively analyzed on the
basis of a simplified shape anisotropy model.Comment: 8 pages, 4 figure
Public servants' expectations and perceptions of their managers' role and behaviour in post-bureaucratic organisations
Simultaneous Refractive Index Sensing Using an Array of Suspended Porous Silicon Membranes
We propose a fast and cost-effective method for
obtaining a miniaturized array-formatted sensor suitable for
multiplexed detection. Our solution is based on the fabrication of
multiple µm-sized suspended porous silicon (PSi) membranes
working as independent transducers. Our process can potentially
integrate an array of up to 1000 sensing spots per cm2
. We also
propose a simple and user-friendly optical platform to
simultaneously interrogate each element of the array in real-time.
The feasibility of this idea was proved performing several sensing
experiments where we were able to detect refractive index (RI)
variations with different transducers at the same time. An average
experimental sensitivity of 685 nm/RIU (Refractive Index Unit)
was achieved, with a theoretical limit of detection (LoD) of 10-5
RIU. The analyzed sensing spots displayed similar behavior both
in time and in magnitude. We believe that the high capabilities of
the sensor presented in this work, along with the sensing
mechanism, can be very useful for multi-parametric analysis and
multi-target detection of biological samples
Motion of a Solitonic Vortex in the BEC-BCS Crossover
We observe a long-lived solitary wave in a superfluid Fermi gas of Li
atoms after phase-imprinting. Tomographic imaging reveals the excitation to be
a solitonic vortex, oriented transverse to the long axis of the cigar-shaped
atom cloud. The precessional motion of the vortex is directly observed, and its
period is measured as a function of the chemical potential in the BEC-BCS
crossover. The long period and the correspondingly large ratio of the inertial
to the bare mass of the vortex are in good agreement with estimates based on
superfluid hydrodynamics that we derive here using the known equation of state
in the BEC-BCS crossover
Sensitivity Comparison of a Self-Standing Porous Silicon Membrane Under Flow-Through and Flow-Over Conditions
An optical sensor based on a self-standing porous silicon (PS) membrane is presented. The sensor was created by electrochemically etching a heavily doped p-type silicon wafer with an organic electrolyte that contained dimethylformamide. After fabrication, a high-current density close to electropolishing was applied in order to allow the detachment from the substrate using a lift-off method. The PS membrane was integrated in a microfluidic cell for sensing purposes, and reflectance spectra were continuously obtained while the target substance was flowed. A comparison of the bulk sensitivity is achieved when flowing through and over the pores is reported. During the experiments, a maximum sensitivity of 770 nm/RIU measured at 1700 nm was achieved. Experimental sensitivity values are in good agreement with the theoretical calculations performed when flowing through the PS membrane, it means that the highest possible sensitivity of that sensor was achieved. In contrast, a drop in the sensitivity of around 25% was observed when flowing over the PS membrane
- …