342 research outputs found

    Do market failures hamper the perspectives of broadband?

    Get PDF
    This report analyses the broadband market and asks whether a specific role of government is necessary. As broadband telecommunication is seen as a source of productivity gains, the European Union and other regions are encouraging the deployment of a secure broadband infrastructure. In the Netherlands, there is some concern whether the supply of broadband capacity will meet the strongly increasing demand. The main conclusions are that presently, given current broadband policy, no considerable market failures exist. Firms have adequate incentives to invest in broadband, partly induced by specific regulation of access to the local copper loop. Hence, there is no need for changes in current broadband policy. Market failures in terms of knowledge spillovers are taken care of by other policies. As the broadband markets are very dynamic, unforeseen developments may emerge such as the appearance of new dominant techniques and market players. The best strategy for the government, in particular the competition authority, is to continuously monitor these markets, making timely intervention easier when needed.

    Centimeter scale atomic force microscope imaging and lithography

    Get PDF
    Cataloged from PDF version of article.We present a 4 mm2 image taken with a parallel array of 10 cantilevers, an image spanning 6.4 mm taken with 32 cantilevers, and lithography over a 100 mm2 area using an array of 50 cantilevers. All of these results represent scan areas that are orders of magnitude larger than that of a typical atomic force microscope (0.01 mm2). Previously, the serial nature and limited scan size of the atomic force microscope prevented large scale imaging. Our design addresses these issues by using a modular micromachined parallel atomic force microscope array in conjunction with large displacement scanners. High-resolution microscopy and lithography over large areas are important for many applications, but especially in microelectronics, where integrated circuit chips typically have nanometer scale features distributed over square centimeter areas. © 1998 American Institute of Physics

    Automated parallel high-speed atomic force microscopy

    Get PDF
    Cataloged from PDF version of article.An expandable system has been developed to operate multiple probes for the atomic force microscope in parallel at high speeds. The combined improvements from parallelism and enhanced tip speed in this system represent an increase in throughput by over two orders of magnitude. A modular cantilever design has been replicated to produce an array of 50 cantilevers with a 200 ÎŒm pitch. This design contains a dedicated integrated sensor and integrated actuator where the cells can be repeated indefinitely. Electrical shielding within the array virtually eliminates coupling between the actuators and sensors. The reduced coupling simplifies the control electronics, facilitating the design of a computer system to automate the parallel high-speed arrays. This automated system has been applied to four cantilevers within the array of 50 cantilevers, with a 20 kHz bandwidth and a noise level of less than 50 Å. For typical samples, this bandwidth allows us to scan the probes at 4 mm/s. © 1998 American Institute of Physic

    Extensibility governs the flow-induced alignment of polymers and rod-like colloids

    Full text link
    Polymers and rod-like colloids (PaRC) adopt a favorable orientation under sufficiently strong flows. However, how the flow kinematics affect the alignment of such nanostructures according to their extensibility remains unclear. By analysing the shear- and extension-induced alignment of chemically and structurally different PaRC, we show that extensibility is a key determinant of the structural response to the imposed kinematics. We propose a unified description of the effectiveness of extensional flow, compared to shearing flow, at aligning PaRC of different extensibility

    Dual integrated actuators for extended range high speed atomic force microscopy

    Get PDF
    Cataloged from PDF version of article.A flexible system for increasing the throughput of the atomic force microscope without sacrificing imaging range is presented. The system is based on a nested feedback loop which controls a micromachined cantilever that contains both an integrated piezoelectric actuator and an integrated thermal actuator. This combination enables high speed imaging (2 mm/s) over an extended range by utilizing the piezoelectric actuator’s high bandwidth (15 kHz) and thermal actuator’s large response (300 nm/V). A constant force image, where the sample topography exceeds the range of the piezoelectric actuator alone, is presented. It has also been demonstrated that the deflection response of the thermal actuator can be linearized and controlled with an integrated diode. © 1999 American Institute of Physic

    High-speed tapping mode imaging with active Q control for atomic force microscopy

    Get PDF
    Cataloged from PDF version of article.The speed of tapping mode imaging with the atomic force microscope(AFM) has been increased by over an order of magnitude. The enhanced operation is achieved by (1) increasing the instrument’s mechanical bandwidth and (2) actively controlling the cantilever’s dynamics. The instrument’s mechanical bandwidth is increased by an order of magnitude by replacing the piezotube z-axis actuator with an integrated zinc oxide (ZnO)piezoelectric cantilever. The cantilever’s dynamics are optimized for high-speed operation by actively damping the quality factor (Q) of the cantilever. Active damping allows the amplitude of the oscillating cantilever to respond to topography changes more quickly. With these two advancements, 80ÎŒm×80 ÎŒm high-speed tapping mode images have been obtained with a scan frequency of 15 Hz. This corresponds to a tip velocity of 2.4 mm/s. © 2000 American Institute of Physic

    Electronic and Structural Disorder of the Epitaxial La<sub>0.67</sub>Sr<sub>0.33</sub>MnO<sub>3</sub> Surface

    Get PDF
    Understanding and tuning epitaxial complex oxide films are crucial in controlling the behavior of devices and catalytic processes. Substrate-induced strain, doping, and layer growth are known to influence the electronic and magnetic properties of the bulk of the film. In this study, we demonstrate a clear distinction between the bulk and surface of thin films of La0.67Sr0.33MnO3 in terms of chemical composition, electronic disorder, and surface morphology. We use a combined experimental approach of X-ray-based characterization methods and scanning probe microscopy. Using X-ray diffraction and resonant X-ray reflectivity, we uncover surface nonstoichiometry in the strontium and lanthanum alongside an accumulation of oxygen vacancies. With scanning tunneling microscopy, we observed an electronic phase separation (EPS) on the surface related to this nonstoichiometry. The EPS is likely driving the temperature-dependent resistivity transition and is a cause of proposed mixed-phase ferromagnetic and paramagnetic states near room temperature in these thin films.</p

    Parallel atomic force microscopy with optical interferometric detection

    Get PDF
    Cataloged from PDF version of article.We have developed an atomic force microscope that uses interferometry for parallel readout of a cantilever array. Each cantilever contains a phase sensitive diffraction grating consisting of a reference and movable set of interdigitated fingers. As a force is applied to the tip, the movable set is displaced and the intensity of the diffracted orders is altered. The order intensity from each cantilever is measured with a custom array of siliconphotodiodes with integrated complementary metal–oxide–semiconductor amplifiers. We present images from five cantilevers acquired in the constant height mode that reveal surface features 2 nm in height. The interdigital method for cantilever array readout is scalable, provides angstrom resolution, and is potentially simpler to implement than other methods. © 2001 American Institute of Physic

    Magnetic resonance imaging of fibroadenoma-like lesions and correlation with Breast Imaging-Reporting and Data System and Kaiser scoring system

    Get PDF
    Background: Multiple breast lesions resembling fibroadenomas are a common imaging finding in patients presenting to the mammography unit at Dr George Mukhari Academic Hospital in the North-West district of Tshwane, South Africa. Patients often present with multiple lesions, up to 20 lesions per breast. These lesions often have atypical features on ultrasound and/or a clinical history of growth is commonly given. Phyllodes tumours may be indistinguishable from fibroadenomas and breast cancers may on occasion present with benign features, which can lead to misdiagnosis. Breast magnetic resonance imaging (bMRI) evaluation of lesions resembling fibroadenomas may improve accurate assessment and identification of lesions requiring biopsy. Objectives: To assess the reliability of bMRI to characterise lesions resembling fibroadenomas on ultrasound, using the Breast Imaging-Reporting and Data System (BI-RADS) and Kaiser scoring systems with histopathological correlation. Method: A quantitative, prospective, investigative study was performed with a sample size of 100 breast lesions among a total of 35 patients at Dr George Mukhari Academic Hospital. Patients were recruited after a breast ultrasound investigation revealed lesions resembling fibroadenomas, but with an indication for ultrasound-guided biopsy, for example, very large size, atypical features on ultrasound or a history of recent growth. The bMRI was performed prior to the ultrasound-guided breast biopsies. Three investigators independently evaluated the bMRI and applied BI-RADS descriptors to each lesion. The Kaiser score was then calculated for each lesion. Statistics were calculated using Pearson’s and Spearman’s coefficients for inter-reader variability, kappa scores for BI-RADS and Kaiser score correlation with histology. Results: Evaluation with bMRI, BI-RADS and the Kaiser scoring system showed statistically significant correlation with each other and with histopathology results for each lesion. There was statistically significant agreement among the investigators regarding the interpretation of the lesions and allocation of appropriate BI-RADS scores. Conclusion: Multiple lesions resembling fibroadenomas can be evaluated with bMRI when multiple breast biopsies would not be feasible. With a good imaging protocol and technique, adequate interpretation skills by the radiologist and the use of the Kaiser scoring system, an accurate diagnosis can be achieved

    Development and Validation of an On-Line Water Toxicity Sensor with Immobilized Luminescent Bacteria for On-Line Surface Water Monitoring.

    Get PDF
    Surface water used for drinking water production is frequently monitored in The Netherlands using whole organism biomonitors, with for exampleDaphnia magnaorDreissenamussels, which respond to changes in the water quality. However, not all human-relevant toxic compounds can be detected by these biomonitors. Therefore, a new on-line biosensor has been developed, containing immobilized genetically modified bacteria, which respond to genotoxicity in the water by emitting luminescence. The performance of this sensor was tested under laboratory conditions, as well as under field conditions at a monitoring station along the river Meuse in The Netherlands. The sensor was robust and easy to clean, with inert materials, temperature control and nutrient feed for the reporter organisms. The bacteria were immobilized in sol-gel on either an optical fiber or a glass slide and then continuously exposed to water. Since the glass slide was more sensitive and robust, only this setup was used in the field. The sensor responded to spikes of genotoxic compounds in the water with a minimal detectable concentration of 0.01 mg/L mitomycin C in the laboratory and 0.1 mg/L mitomycin C in the field. With further optimization, which should include a reduction in daily maintenance, the sensor has the potential to become a useful addition to the currently available biomonitors
    • 

    corecore