30 research outputs found

    Towards screening Barrett’s Oesophagus: current guidelines, imaging modalities and future developments

    Get PDF
    Barrett’s oesophagus is the only known precursor to oesophageal adenocarcinoma (OAC). Although guidelines on the screening and surveillance exist in Barrett’s oesophagus, the current strategies are inadequate. Oesophagogastroduodenoscopy (OGD) is the gold standard method in screening for Barrett’s oesophagus. This invasive method is expensive with associated risks negating its use as a current screening tool for Barrett’s oesophagus. This review explores current definitions, epidemiology, biomarkers, surveillance, and screening in Barrett’s oesophagus. Imaging modalities applicable to this condition are discussed, in addition to future developments. There is an urgent need for an alternative non-invasive method of screening and/or surveillance which could be highly beneficial towards reducing waiting times, alleviating patient fears and reducing future costs in current healthcare services. Vibrational spectroscopy has been shown to be promising in categorising Barrett’s oesophagus through to high-grade dysplasia (HGD) and OAC. These techniques need further validation through multicentre trials

    Polyp recurrence after endoscopic mucosal resection of sessile and flat colonic adenomas

    No full text
    Background: Endoscopic mucosal resection (EMR) is used for treatment of sessile and flat colonic adenomas. There is limited data comparing polyp recurrence between piecemeal and en-bloc resections. Aim: The purpose of this study was to evaluate the incidence density and predictive factors for polyp recurrence after piecemeal and en-bloc resections. Methods: Patients undergoing EMR of flat or sessile adenomas C10 mm were included. Incidence density (ID) and incidence rate ratio (IRR) of polyp recurrence were calculated. Predictive factors for recurrence were assessed by multivariate analysis using logistic regression. Results: A total of 105 patients (males 54, mean age 68) with 121 polyps were included. Sixty-seven polyps (mean size ± SD, 23.3 ± 9.2 mm) were resected piecemeal and 54 polyps (mean size 14.7 ± 5.1 mm) were resected enbloc. There were 12 recurrences in the piecemeal group and two in the en-bloc group. The ID of polyp recurrence in the piecemeal group was 13.1 (95% CI 7.43–23.03) and in the en-bloc group was 2.7 (95% CI 0.67–10.78) per 100 person-years of follow-up. Piecemeal resections were 5.5 (95% CI 1.1–30.48, P = 0.045) times and flat polyps were 6.6 (95% CI 1.22–35.53, P = 0.028) times more likely to result in recurrence compared to en-bloc resections and sessile polyps, respectively. In the piecemeal group, additional use of argon plasma coagulation (APC) did not affect the recurrence (OR 0.46, P = 0.29). Conclusions: Piecemeal resections and flat polyps are associated with higher recurrence following EMR. Additional use of APC did not affect the recurrence rates after piecemeal resection.J. Mannath, V. Subramanian, R. Singh, E. Telakis and K. Ragunat

    Evaluation of a novel infra-red endoscopy system in the assessment of early neoplasia in Barretts esophagus: pilot study from a single center

    No full text
    Infrared endoscopy (IRE) has been shown to be useful in detecting submucosal (SM) invasion in early gastric cancer. Its role in the endoscopic assessment of Barrett's neoplasia has not been reported to date. We aimed in this study to evaluate the role of IRE in the detection and characterization of early neoplastic lesions within Barrett's esophagus (BE). The secondary aim was to explore its usefulness for the assessment of the presence of submucosal invasion in these early neoplastic Barrett's lesions. We included in the study patients with dysplastic BE who were referred to our institution for endoscopic therapy of a previously diagnosed early Barrett's neoplasia. An examination with white light high resolution endoscopy (HRE) and near IRE after intravenous injection of indocyanine green was performed for all patients using an infrared endoscope prototype. Staining on IRE and correlation with final histological staging by endoscopic mucosal resection/surgery or histological diagnosis on mapping biopsies was analyzed. A total of 23 patients were enrolled in our study: 17 of them with 19 visible lesions and 6 patients with flat BE and no lesions. Staining on IRE was noted in 18 cases: 17 (94%) had at least high grade dysplasia (HGD). No stain was noted in 7 cases: final histology was <HGD in 5 (71%) and ≄HGD in 2 (29%). There was statistically significant difference between cases with no stain and any staining on IRE with regard to the presence of ≄HGD [2/7 (29%) vs. 17/18 (94%) P = 0.0022]. Stain was reported as faint in 12 and dense in 6. All 6 cases with dense staining had at least HGD. We concluded that IRE can provide additional information to the currently available white light endoscopy for detecting early neoplastic lesions within BE. IRE also allows detecting HGD and most advanced histology in BE. Usefulness of IRE to detect submucosal involvement in early Barrett's neoplastic lesions needs to be assessed further in larger cohort studies

    Narrow band imaging and serology in the assessment of premalignant gastric pathology

    No full text
    BACKGROUND: Patient outcomes in gastric adenocarcinoma are poor due to late diagnosis. Detecting and treating at the premalignant stage has the potential to improve this. Helicobacter pylori is also a strong risk factor for this disease. AIMS: Primary aims were to assess the diagnostic accuracy of magnified narrow band imaging (NBI-Z) endoscopy and serology in detecting normal mucosa, H. pylori gastritis and gastric atrophy. Secondary aims were to compare the diagnostic accuracies of two classification systems using both NBI-Z and white light endoscopy with magnification (WLE-Z) and evaluate the inter-observer agreement. METHODS: Patients were prospectively recruited. Images of gastric mucosa were stored with histology and serum for IgG H. pylori and Pepsinogen (PG) I/II ELISAs. Blinded expert endoscopists agreed on mucosal pattern. Mucosal images and serological markers were compared with histology. Kappa statistics determined inter-observer variability for randomly allocated images among four experts and four non-experts. RESULTS: 116 patients were prospectively recruited. Diagnostic accuracy of NBI-Z for determining normal gastric mucosa was 0.87(95%CI 0.82-0.92), H. pylori gastritis 0.65(95%CI 0.55-0.75) and gastric atrophy 0.88(95%CI 0.81-0.94). NBI-Z was superior to serology at detecting gastric atrophy: NBI-Z gastric atrophy 0.88(95%CI 0.81-0.94) vs PGI/II ratio < 3 0.74(95%CI 0.62-0.85) p<.0001. Overall NBI-Z was superior to WLE-Z in detecting disease using two validated classifications. Inter-observer agreement was 0.63(95%CI 0.51-0.73). CONCLUSIONS: NBI-Z accurately detects changes in the GI mucosa which currently depend on histology. NBI-Z is useful in the detection of precancerous conditions, potentially improving patient outcomes with early intervention to prevent gastric cancer
    corecore