85 research outputs found

    The Electron Cyclotron Resonance Light Source Assembly of PTB - ELISA

    Get PDF
    In the radiometry laboratory of the Physikalisch-Technische,Bundesanstalt at the Berlin electron storage ring BESSY I, radiation sources for radiometric applications in industry and basic research in the vacuum ultraviolet (VUV) spectral range are developed, characterized and calibrated. Established sources such as deuterium lamps, Penning and hollow cathode discharge sources have limited spectral ranges and in particular their stability and life time suffers from the erosion of the cathode material. To overcome these limitations we have developed a radiation source based on the principle of the electron cyclotron resonance ion source. ELISA is a 10 GHz monomode source with a compact design featuring a tunable cavity and axially positionable permanent magnets. The radiation emission of the source can be detected simultaneously in the VUV and X-ray spectral range via a toroidal grating monochromator and a Si(Li)-detector. The special design of the source allows spectroscopic investigations of the plasma in dependence on the cavity tuning and magnet position. A marked influence of tuning and magnet position on the radiant intensity of the VUV and X-ray emission was observed. Using the tuning potential of ELISA krypton plasmas with highly charged ions and intense VUV radiation are generated by very low power consumption in comparison to other VUV radiation sources

    Radiometric calibration of the in-flight blackbody calibration system of the GLORIA interferometer

    Get PDF
    GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) is an airborne, imaging, infrared Fourier transform spectrometer that applies the limb-imaging technique to perform trace gas and temperature measurements in the Earth's atmosphere with three-dimensional resolution. To ensure the traceability of these measurements to the International Temperature Scale and thereby to an absolute radiance scale, GLORIA carries an on-board calibration system. Basically, it consists of two identical large-area and high-emissivity infrared radiators, which can be continuously and independently operated at two adjustable temperatures in a range from −50 °C to 0 °C during flight. Here we describe the radiometric and thermometric characterization and calibration of the in-flight calibration system at the Reduced Background Calibration Facility of the Physikalisch-Technische Bundesanstalt. This was performed with a standard uncertainty of less than 110 mK. Extensive investigations of the system concerning its absolute radiation temperature and spectral radiance, its temperature homogeneity and its short- and long-term stability are discussed. The traceability chain of these measurements is presented

    Radiometric calibration of the in-flight blackbody calibration system of the GLORIA interferometer

    Get PDF
    GLORIA (Gimballed Limb Observer for Radiance Imaging of the Atmosphere) is an airborne, imaging, infrared Fourier transform spectrometer that applies the limb-imaging technique to perform trace gas and temperature measurements in the Earth's atmosphere with three-dimensional resolution. To ensure the traceability of these measurements to the International Temperature Scale and thereby to an absolute radiance scale, GLORIA carries an on-board calibration system. Basically, it consists of two identical large-area and high-emissivity infrared radiators, which can be continuously and independently operated at two adjustable temperatures in a range from −50 °C to 0 °C during flight. Here we describe the radiometric and thermometric characterization and calibration of the in-flight calibration system at the Reduced Background Calibration Facility of the Physikalisch-Technische Bundesanstalt. This was performed with a standard uncertainty of less than 110 mK. Extensive investigations of the system concerning its absolute radiation temperature and spectral radiance, its temperature homogeneity and its short- and long-term stability are discussed. The traceability chain of these measurements is presented

    Characterizing the cross dispersion reflection gratings of CRIRES+

    Get PDF
    The CRIRES+ project attempts to upgrade the CRIRES instrument into a cross dispersed Echelle spectrograph with a simultaneous recording of 8-10 diffraction orders. In order to transform the CRIRES spectrograph into a cross-dispersing instrument, a set of six reflection gratings, each one optimized for one of the wavelength bands CRIRES+ will operate in (YJHKLM), will be used as cross dispersion elements in CRIRES+. Due to the upgrade nature of the project, the choice of gratings depends on the fixed geometry of the instrument. Thus, custom made gratings would be required to achieve the ambitious design goals. Custom made gratings have the disadvantage, though, that they come at an extraordinary price and with lead times of more than 12 months. To mitigate this, a set of off-the-shelf gratings was obtained which had grating parameters very close to the ones being identified as optimal. To ensure that the rigorous specifications for CRIRES+ will be fulfilled, the CRIRES+ team started a collaboration with the Physikalisch-Technische Bundesanstalt Berlin (PTB) to characterize gratings underconditions similar to the operating conditions in CRIRES+ (angle of incidence, wavelength range). The respective test setup was designed in collaboration between PTB and the CRIRES+ consortium. The PTB provided optical radiation sources and calibrated detectors for each wavelength range. With this setup, it is possible to measure the absolute efficiency of the gratings both wavelength dependent and polarization state dependent in a wavelength range from 0.9 μm to 6 μm
    corecore