13 research outputs found
High performance FPGA and GPU complex pattern matching over spatio-temporal streams
The wide and increasing availability of collected data in the form of trajectories has led to research advances in behavioral aspects of the monitored subjects (e.g., wild animals, people, and vehicles). Using trajectory data harvested by devices, such as GPS, RFID and mobile devices, complex pattern queries can be posed to select trajectories based on specific events of interest. In this paper, we present a study on FPGA- and GPU-based architectures processing complex patterns on streams of spatio-temporal data. Complex patterns are described as regular expressions over a spatial alphabet that can be implicitly or explicitly anchored to the time domain. More importantly, variables can be used to substantially enhance the flexibility and expressive power of pattern queries. Here we explore the challenges in handling several constructs of the assumed pattern query language, with a study on the trade-offs between expressiveness, scalability and matching accuracy. We show an extensive performance evaluation where FPGA and GPU setups outperform the current state-of-the-art (single-threaded) CPU-based approaches, by over three orders of magnitude for FPGAs (for expressive queries) and up to two orders of magnitude for certain datasets on GPUs (and in some cases slowdown). Unlike software-based approaches, the performance of the proposed FPGA and GPU solutions is only minimally affected by the increased pattern complexity
Multicentre observational study on multisystem inflammatory syndrome related to COVID-19 in Argentina
Background: The impact of the pediatric inflammatory multisystem syndrome temporally associated with SARS-CoV-2 (PIMS-TS) in low- and middle-income countries remains poorly understood. Our aim was to understand the characteristics and outcomes of PIMS-TS in Argentina. Methods: This observational, prospective, and retrospective multicenter study enrolled patients younger than 18 years-old manifesting PIMS-TS, Kawasaki disease (KD) or Kawasaki shock syndrome (KSS) between March 2020 and May 2021. Patients were followed-up until hospital discharge or death (one case). The primary outcome was pediatric intensive care unit (PICU) admission. Multiple logistic regression was used to identify variables predicting PICU admission. Results: Eighty-one percent, 82%, and 14% of the 176 enrolled patients fulfilled the suspect case criteria for PIMS-TS, KD, and KSS, respectively. Temporal association with SARS-CoV-2 was confirmed in 85% of the patients and 38% were admitted to the PICU. The more common clinical manifestations were fever, abdominal pain, rash, and conjunctival injection. Lymphopenia was more common among PICU-admitted patients (87% vs. 51%, p < 0.0001), who also showed a lower platelet count and higher plasmatic levels of inflammatory and cardiac markers. Mitral valve insufficiency, left ventricular wall motion alterations, pericardial effusion, and coronary artery alterations were observed in 30%, 30%, 19.8%, and 18.6% of the patients, respectively. Days to initiation of treatment, rash, lymphopenia, and low platelet count were significant independent contributions to PICU admission. Conclusion: Rates of severe outcomes of PIMS-TS in the present study agreed with those observed in high-income countries. Together with other published studies, this work helps clinicians to better understand this novel clinical entity.Fil: Vainstein, Eduardo. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños "Ricardo GutiĂ©rrez"; ArgentinaFil: Baleani, Silvia. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños "Ricardo GutiĂ©rrez"; ArgentinaFil: Urrutia, Luis. Gobierno de la Ciudad de Buenos Aires. Hospital de PediatrĂa "Juan P. Garrahan"; ArgentinaFil: Affranchino, Nicolás. Gobierno de la Ciudad de Buenos Aires. Hospital de PediatrĂa "Juan P. Garrahan"; ArgentinaFil: Ackerman, Judith. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños Pedro Elizalde (ex Casa Cuna); ArgentinaFil: Cazalas, Mariana. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños "Ricardo GutiĂ©rrez"; ArgentinaFil: Goldsman, Alejandro. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños "Ricardo GutiĂ©rrez"; ArgentinaFil: Sardella, Angela. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños "Ricardo GutiĂ©rrez"; ArgentinaFil: Tolin, Ana Laura. Gobierno de la Provincia de Mendoza. Hospital Pediátrico Humberto Notti; ArgentinaFil: Goldaracena, Pablo. Provincia de Buenos Aires. Ministerio de Salud. Hospital de Niños "Sor MarĂa Ludovica" de La Plata; ArgentinaFil: Fabi, Mariana. Provincia de Buenos Aires. Ministerio de Salud. Hospital de Niños "Sor MarĂa Ludovica" de La Plata; ArgentinaFil: Cosentino, Mariana. Hospital Británico de Buenos Aires; ArgentinaFil: Magliola, Ricardo. Hospital Británico de Buenos Aires; ArgentinaFil: Roggiero, Gustavo. Provincia de Buenos Aires. Ministerio de Salud. Hospital Alta Complejidad en Red El Cruce Dr. NĂ©stor Carlos Kirchner Samic; ArgentinaFil: Manso, Paula. Provincia de Buenos Aires. Ministerio de Salud. Hospital Alta Complejidad en Red El Cruce Dr. NĂ©stor Carlos Kirchner Samic; ArgentinaFil: Triguy, JĂ©sica. Gobierno de la Provincia de Mendoza. Hospital Pediátrico Humberto Notti; ArgentinaFil: Ballester, Celeste. Gobierno de la Provincia de Mendoza. Hospital Pediátrico Humberto Notti; ArgentinaFil: Cervetto, Vanesa. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños Pedro Elizalde (ex Casa Cuna); ArgentinaFil: Vaccarello, MarĂa. Sanatorio de la Trinidad; ArgentinaFil: De Carli, Domingo Norberto. ClĂnica del Niño de Quilmes; ArgentinaFil: De Carli, Maria Estela. ClĂnica del Niño de Quilmes; ArgentinaFil: Ciotti, Ana Laura. Hospital Nacional Profesor Alejandro Posadas; ArgentinaFil: Sicurello, MarĂa Irene. Gobierno de la Ciudad de Buenos Aires. Hospital General de Niños "Ricardo GutiĂ©rrez"; ArgentinaFil: Rios Leiva, Cecilia. Provincia de Buenos Aires. Ministerio de Salud. Hospital Interzonal de Agudos "Eva PerĂłn"; ArgentinaFil: Villalba, Claudia. Gobierno de la Ciudad de Buenos Aires. Hospital de PediatrĂa "Juan P. Garrahan"; ArgentinaFil: Hortas, MarĂa. Sanatorio de la Trinidad; ArgentinaFil: Peña, Sonia. Gobierno de la Provincia de Mendoza. Hospital Pediátrico Humberto Notti; ArgentinaFil: González, Gabriela. Gobierno de la Provincia de Mendoza. Hospital Pediátrico Humberto Notti; ArgentinaFil: Zold, Camila Lidia. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Oficina de CoordinaciĂłn Administrativa Houssay. Instituto de FisiologĂa y BiofĂsica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de FisiologĂa y BiofĂsica Bernardo Houssay; ArgentinaFil: Murer, Mario Gustavo. Consejo Nacional de Investigaciones CientĂficas y TĂ©cnicas. Oficina de CoordinaciĂłn Administrativa Houssay. Instituto de FisiologĂa y BiofĂsica Bernardo Houssay. Universidad de Buenos Aires. Facultad de Medicina. Instituto de FisiologĂa y BiofĂsica Bernardo Houssay; ArgentinaFil: Grippo, M.. No especifĂca;Fil: Vázquez, H.. No especifĂca;Fil: MorĂłs, C.. No especifĂca;Fil: Di Santo, M.. No especifĂca;Fil: Villa, A.. No especifĂca;Fil: Lazota, P.. No especifĂca;Fil: Foti, M.. No especifĂca;Fil: Napoli, N.. No especifĂca;Fil: Katsikas, M. M.. No especifĂca;Fil: Tonello, L.. No especifĂca;Fil: Peña, J.. No especifĂca;Fil: Etcheverry, M.. No especifĂca;Fil: Iglesias, D.. No especifĂca;Fil: Alcalde, A. L.. No especifĂca;Fil: Bruera, M.J.. No especifĂca;Fil: Bruzzo, V.. No especifĂca;Fil: Giordano, P.. No especifĂca;Fil: Pena Acero, F.. No especifĂca;Fil: Netri Pelandi, G.. No especifĂca;Fil: Pastaro, D.. No especifĂca;Fil: Bleiz, J.. No especifĂca;Fil: RodrĂguez, M. F.. No especifĂca;Fil: Laghezza, L.. No especifĂca;Fil: Molina, M. B.. No especifĂca;Fil: Patynok, N.. No especifĂca;Fil: Chatelain, M. S.. No especifĂca;Fil: Aguilar, M. J.. No especifĂca;Fil: Gamboa, J.. No especifĂca;Fil: Cervan, M.. No especifĂca;Fil: Ruggeri, A.. No especifĂca;Fil: Marinelli, I.. No especifĂca;Fil: Checcacci, E.. No especifĂca;Fil: Meregalli, C.. No especifĂca;Fil: Damksy Barbosa, J.. No especifĂca;Fil: Fernie, L.. No especifĂca;Fil: Fernández, M. J.. No especifĂca;Fil: Saenz Tejeira, M.M.. No especifĂca;Fil: Cereigido, C.. No especifĂca;Fil: Nunell, A.. No especifĂca;Fil: Villar, D.. No especifĂca;Fil: Mansilla, A. D.. No especifĂca;Fil: Darduin, M. D.. No especifĂca
Recommended from our members
Design, construction, and analysis of a skin contamination dosimeter
International recommendations provided by the International Commission on Radiation Protection (ICRP), as well as national regulations, set by the U.S. Nuclear Regulatory Commission (NRC), state that the exposure of skin to highly concentrated radioactive sources should be monitored at specified depths in skin and kept below specific dose equivalence levels. In this work, a prototypic skin contamination dosimeter designed for dose verification and compliance, as described in the Code of Federal Regulations (10CFR20), is designed, constructed, characterized, and calibrated. The dosimeter is modeled and compared against Monte Carlo Nth Particle version 5 particle transport code simulations. The detection of radiation is carried out with scintillation layers intended to give an absolute measure of absorbed dose to the shallow, and deep layers of skin, as well as to the lens of the eye and a layer in skin biologically significant in stochastic effects. The scintillation layers are installed into a scintillation assembly, which provides a tissue-equivalent medium for radiation interactions
Pulse Shape Discrimination with a Low-cost Digitizer Using Commercial Off-the-shelf Components
Pulse shape discrimination of neutrons and gammas is demonstrated using a FemtoDAQ, a low-cost digitizer that uses commercial off-the-shelf components. This digitizer is paired with a CLYC scintillator coupled to a photomultiplier tube to concurrently detect neutrons and gammas. Python code was written to analyze the detector waveforms to determine the energy deposited and distinguish neutron and gamma events within the CLYC crystal. The energy of each waveform is determined by the summation of the discrete amplitudes recorded by the digitizer for each pulse. This method is compared to a traditional multichannel analyzer operating with commercial software for validation and shown to produce the same energy spectrum. Pulse shape discrimination is accomplished by measuring and summing the amplitudes of the prompt portion of each waveform (first 80 ns) and the delayed portion (following 500 ns) and then calculating a ratio of the delayed region to the total. This technique was able to clearly distinguish thermal neutron events from gamma events with a figure of merit of 1.42
Gamma-ray Radiation Effects in Graphene-based Transistors with h-BN Nanometer Film Substrates
Radiation effects on graphene field effect transistors (GFETs) with hexagonal boron nitride (h-BN) thin film substrates are investigated using 60Co gamma-ray radiation. This study examines the radiation response using many samples with varying h-BN film thicknesses (1.6 and 20 nm thickness) and graphene channel lengths (5 and 10 ÎĽm). These samples were exposed to a total ionizing dose of approximately 1 Mrad(Si). I-V measurements were taken at fixed time intervals between irradiations and postirradiation. Dirac point voltage and current are extracted from the I-V measurements, as well as mobility, Dirac voltage hysteresis, and the total number of GFETs that remain properly operational. The results show a decrease in Dirac voltage during irradiation, with a rise of this voltage and permanent drop in Dirac current postirradiation. 1.6 nm h-BN substrate GFETs show an increase in mobility during irradiation, which drops back to preirradiation conditions in postirradiation measurements. Hysteretic changes to the Dirac voltage are the strongest during irradiation for the 20 nm thick h-BN substrate GFETs and after irradiation for the 1.6 nm thick h-BN GFETs. Failure rates were similar for most GFET types during irradiation; however, after irradiation, GFETs with 20 nm h-BN substrates experienced substantially more failures compared to 1.6 nm h-BN substrate GFETs
Gamma-ray radiation effects in graphene-based transistors with h-BN nanometer film substrates
Radiation effects on graphene field effect transistors (GFETs) with hexagonal boron nitride (h-BN) thin film substrates are investigated using 60Co gamma-ray radiation. This study examines the radiation response using many samples with varying h-BN film thicknesses (1.6 and 20 nm thickness) and graphene channel lengths (5 and 10 ÎĽm). These samples were exposed to a total ionizing dose of approximately 1 Mrad(Si). I-V measurements were taken at fixed time intervals between irradiations and postirradiation. Dirac point voltage and current are extracted from the I-V measurements, as well as mobility, Dirac voltage hysteresis, and the total number of GFETs that remain properly operational. The results show a decrease in Dirac voltage during irradiation, with a rise of this voltage and permanent drop in Dirac current postirradiation. 1.6 nm h-BN substrate GFETs show an increase in mobility during irradiation, which drops back to preirradiation conditions in postirradiation measurements. Hysteretic changes to the Dirac voltage are the strongest during irradiation for the 20 nm thick h-BN substrate GFETs and after irradiation for the 1.6 nm thick h-BN GFETs. Failure rates were similar for most GFET types during irradiation; however, after irradiation, GFETs with 20 nm h-BN substrates experienced substantially more failures compared to 1.6 nm h-BN substrate GFETs
Position-dependent and millimetre-range photodetection in phototransistors with micrometre-scale graphene on SiC.
The extraordinary optical and electronic properties of graphene make it a promising component of high-performance photodetectors. However, in typical graphene-based photodetectors demonstrated to date, the photoresponse only comes from specific locations near graphene over an area much smaller than the device size. For many optoelectronic device applications, it is desirable to obtain the photoresponse and positional sensitivity over a much larger area. Here, we report the spatial dependence of the photoresponse in backgated graphene field-effect transistors (GFET) on silicon carbide (SiC) substrates by scanning a focused laser beam across the GFET. The GFET shows a nonlocal photoresponse even when the SiC substrate is illuminated at distances greater than 500 µm from the graphene. The photoresponsivity and photocurrent can be varied by more than one order of magnitude depending on the illumination position. Our observations are explained with a numerical model based on charge transport of photoexcited carriers in the substrate