48 research outputs found

    Movement representation strategies as a tool for educational innovation in physiotherapy students: a randomized single-blind controlled-pilot trial

    Get PDF
    Physiotherapy has a strictly theoretical body of knowledge, but for the most part, the physiotherapist’s learning is practical. The practical part is fundamental to acquire clinical skills that the physiotherapist will later use in professional practice. The main aim of this study was to assess the effectiveness of movement representation strategies (MRS) in the improvement of manual skills of physiotherapy students as an educational innovation strategy. We randomly assigned 30 participants to an action observation practice (AOP), motor imagery practice (MIP), or sham observation (SO) group. A high velocity, low amplitude lumbar manipulation technique that is widely used in clinical physiotherapy practice was taught in one session. The primary outcomes were required time and test score. The secondary outcomes were perceived mental fatigue and perceived difficulty for learning. The outcomes were assessed preintervention and immediately after the intervention (postintervention). The main results showed that both AOP and MIP improved the total time required and the test score, as well as entailed less perceived difficulty for learning. However, both strategies showed a higher level of mental fatigue after the intervention, which was higher in the MIP group. Based on the results obtained, it seems that the application of MRS promotes greater learning of manual motor tasks in physiotherapy students and could be used as educational innovation strategies

    Physical Activity Monitoring and Acceptance of a Commercial Activity Tracker in Adult Patients with Haemophilia

    Get PDF
    Physical activity (PA) is highly beneficial for people with haemophilia (PWH), however, studies that objectively monitor the PA in this population are scarce. This study aimed to monitor the daily PA and analyse its evolution over time in a cohort of PWH using a commercial activity tracker. In addition, this work analyses the relationship between PA levels, demographics, and joint health status, as well as the acceptance and adherence to the activity tracker. Twenty-six PWH were asked to wear a Fitbit Charge HR for 13 weeks. According to the steps/day in the first week, data were divided into two groups: Active Group (AG; ≥10,000 steps/day) and Non-Active Group (NAG; 0.05) in PA levels or adherence to wristband were produced. Only the correlation between very active minutes and arthropathy was significant (r = −0.40, p = 0.045). Results of the questionnaire showed a high level of satisfaction. In summary, PWH are able to comply with the PA recommendations, and the Fitbit wristband is a valid tool for a continuous and long-term monitoring of PA. However, by itself, the use of a wristband is not enough motivation to increase PA levels

    Design and validation of the INCUE questionnaire: assessment of primary healthcare nurses’ basic training needs in palliative care

    Get PDF
    Many instruments have been created to measure knowledge and attitudes in palliative care. However, not only is it important to acquire knowledge, but also that this knowledge should reach patients and their relatives through application in clinical practice. This study aimed to develop and psychometrically test the INCUE questionnaire (Investigación Cuidados Enfermeros/Investigation into Nurses’ Care Understanding of End-of-Life) to assess the basic training needs of primary or home healthcare nurses in palliative care. A questionnaire was developed based on the classical theory of tests and factor analysis models. Initially, 18 experts developed 67 items in two blocks and determined content validity by two rounds of expert panels. Exploratory factor analysis and reliability testing were conducted with a non-probabilistic sample of 370 nurses. Some items were observed to have very low homogeneity indices or presented convergence problems and were eliminated. Questionnaire reliability was 0.700 in the theoretical block (KR20 Index) and 0.941 in the practical block (Cronbach’s alpha). The model converges and shows an adequate fit, specifically CFI = 0.977, TLI = 0.977 and RMSEA = 0.05. The correlation between the two factors in the model is ρ = 0.63. The questionnaire objectively evaluates primary or home healthcare nurses’ knowledge of palliative care and its practical application, thereby facilitating more efficient training plans

    Safety, Fear and Neuromuscular Responses after a Resisted Knee Extension Performed to Failure in Patients with Severe Haemophilia

    Get PDF
    Background: low–moderate intensity strength training to failure increases strength and muscle hypertrophy in healthy people. However, no study assessed the safety and neuromuscular response of training to failure in people with severe haemophilia (PWH). The purpose of the study was to analyse neuromuscular responses, fear of movement, and possible adverse effects in PWH, after knee extensions to failure. Methods: twelve severe PWH in prophylactic treatment performed knee extensions until failure at an intensity of five on the Borg CR10 scale. Normalised values of amplitude (nRMS) and neuromuscular fatigue were determined using surface electromyography for the rectus femoris, vastus medialis, and vastus lateralis. After the exercise, participants were asked about their perceived change in fear of movement, and to report any possible adverse effects. Results: Patients reported no adverse effects or increased fear. The nRMS was maximal for all the muscles before failure, the median frequency decreased, and wavelet index increased during the repetitions. The vastus lateralis demonstrated a higher maximum nRMS threshold and earlier fatigue, albeit with a lower and more progressive overall fatigue. Conclusions: severe PWH with adequate prophylactic treatment can perform knee extensions to task failure using a moderate intensity, without increasing fear of movement, or adverse effects

    EMG, Rate of Perceived Exertion, Pain, Tolerability and Possible Adverse Effects of a Knee Extensor Exercise with Progressive Elastic Resistance in Patients with Severe Haemophilia

    Get PDF
    In people with haemophilia (PWH), elastic band training is considered an optimal option, even though the literature is scarce. The aim was to evaluate normalized electromyographic amplitude (nEMG), rate of perceived exertion (RPE), pain, tolerability, and possible adverse effects during the knee extension exercise using multiple elastic resistance intensities in PWH. During a single session, 14 severe PWH undergoing prophylactic treatment performed knee extensions without resistance and with different intensity levels of elastic resistance. nEMG was measured for the knee extensors and participants rated their RPE, tolerability and pain intensity after each condition. Patients had to report the possible adverse effects after the session. In most of the cases, an nEMG increase is only evidenced after increasing the resistance by two to three levels. Significant associations were found between RPE and the nEMG (ρ = 0.61), as well as between the elastic resistance level and nEMG (ρ = 0.69) and RPE (ρ = 0.71). All conditions were generally tolerated, without increased pain, and no adverse effects were reported. A wide variety of elastic resistance intensities during the knee extension are safe, tolerated, and do not increase knee pain in the majority of severe PWH undergoing prophylactic treatment

    Experimental characterization and test-beam results of MACACO III Compton camera

    Get PDF
    The IRIS group at IFIC-Valencia is developing a Compton camera prototype with the aim of applying it in hadron therapy treatment monitoring. Recently, a third version of the prototype MACACO (Medical Applications CompAct COmpton camera) has been built. The system is composed of three Lanthanum (III) bromide scintillator crystals coupled to silicon photomultipliers. To improve its performance for the final application, several detectors are tested, two different silicon photomultipliers (25 and 50 um) have been chosen as possible candidates. The 25 up photodetector provided better performance in therms of dynamic range, energy resolution (5.2/ FWHM at 511 keV) and stability with temperature variations. MACACO III has also been tested in the CNA cyclotron (Seville) with 18 MeV proton beam to produce 4.439 MeV gamma rays. Data have been acquired with a graphite target in five different positions at 2.5 nA nominal beam intensity. Images with 4.439 MeV photons have been reconstructed, demonstrating the system capability to reconstruct images at energies relevant for hadron therapy. Moreover, the system has been able to distinguish 1mm displacements in the target position

    Gamma-ray sources imaging and test-beam results with MACACO III Compton camera

    Get PDF
    Hadron therapy is a radiotherapy modality which offers a precise energy deposition to the tumors and a dose reduction to healthy tissue as compared to conventional methods. However, methods for real-time monitoring are required to ensure that the radiation dose is deposited on the target. The IRIS group of IFIC-Valencia developed a Compton camera prototype for this purpose, intending to image the Prompt Gammas emitted by the tissue during irradiation. The system detectors are composed of Lanthanum (III) bromide scintillator crystals coupled to silicon photomultipliers. After an initial characterization in the laboratory, in order to assess the system capabilities for future experiments in proton therapy centers, different tests were carried out in two facilities: PARTREC (Groningen, The Netherlands) and the CNA cyclotron (Sevilla, Spain). Characterization studies performed at PARTREC indicated that the detectors linearity was improved with respect to the previous version and an energy resolution of 5.2 % FWHM at 511 keV was achieved. Moreover, the imaging capabilities of the system were evaluated with a line source of 68Ge and a point-like source of 241Am-9Be. Images at 4.439 MeV were obtained from irradiation of a graphite target with an 18 MeV proton beam at CNA, to perform a study of the system potential to detect shifts at different intensities. In this sense, the system was able to distinguish 1 mm variations in the target position at different beam current intensities for measurement times of 1800 and 600 s.</p
    corecore