297 research outputs found
Nurse Scheduling with State-of-the Art Open-Source Tools
Nurse scheduling is still an unsolved issue, as it is NP-hard and highly context-dependent. Despite this fact, the practice needs guidance on how to tackle this problem without using costly commercial tools. Concretely, we have the following use case: a Swiss hospital is planning a new station designed for nurse training. The capacity planning is finished, and the hospital wants to assess whether shift planning with known constraints leads to valid solutions. Here, a mathematical model is combined with a genetic algorithm. We trust the solution of the mathematical model more, but if it does not provide a valid solution, we try out an alternative. Our solutions indicate that actual capacity planning together with the hard constraints cannot lead to valid staff schedules. The central conclusion is that more degrees of freedom are necessary and that open-source tools OMPR and DEAP are valuable alternatives to commercial products such as Wrike or Shiftboard, in which the degree of freedom of customization is reduced in favor of easiness of use
Purification of the food-borne carcinogens 2-amino-3-methylimidazo [4,5-f]quinoline and 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline in heated meat products by immunoaffinity chromatography
A rapid and simple scheme has been developed for the isolation and purification of two of the major mutagenic heterocyclic amines formed in heated beef products by affinity chromatography using monoclonal antibodies which recognize 2-amino-3-methylimidazo(4,5-f]quinoline (IQ). Two cell lines producing IgG antibodies were established following fusion of Sp2 or P3x.63 myeloma cells with spleen cells of immunized BALB/cby mice. The antigen was bovine gamma globulin haptenized with 2-(3-carboxypropylthio)-3-methylimidazo[4,5-f]quinoline. The antibodies were immobilized on CNBr-activated Sepharose 4B. IQ and MeIQx formed in heated beef products were partially purified by XAD-2 chromatography and then applied to the affinity columns. Purification by affinity chromatography was adequate for subsequent quantitative analysis by HPLC with UV detection. With this purification scheme as little as 1 g of beef extract or 15 g of fried beef could be assayed for IQ and MeIQx at the part per billion level. Both antibodies had similar affinity constants for IQ (9.3 × 106 and 6.7 × 106 M−1) and for MeIQx (7.1 × 105 and 2.7 × 105 M−1) and both were suitable for immunoaffinity purification of IQ from complex mixtures. MAb2 could be used as well to selectively remove MeIQx from meat products after partial purification by XAD-2. MAb1, despite having a 3-fold higher affinity than MAb2 for MeIQx, could not be used for affinity chromatography for this mutage
The role of ureteric indocyanine green fluorescence in colorectal surgery: a retrospective cohort study.
BACKGROUND
Ureteric injury (UI) is an infrequent but serious complication of colorectal surgery. Prophylactic ureteric stenting is employed to avoid UI, yet its efficacy remains debated. Intraoperative indocyanine green fluorescence imaging (ICG-FI) has been used to facilitate ureter detection. This study aimed to investigate the role of ICG-FI in identification of ureters during colorectal surgery and its impact on the incidence of UI.
METHODS
A retrospective cohort study involving 556 consecutive patients who underwent colorectal surgery between 2018 and 2023 assessed the utility of routine prophylactic ureteric stenting with adjunctive ICG-FI. Patients with ICG-FI were compared to those without ICG-FI. Demographic data, operative details, and postoperative morbidity were analyzed. Statistical analysis included univariable regression.
RESULTS
Ureteric ICG-FI was used in 312 (56.1%) patients, whereas 43.9% were controls. Both groups were comparable in terms of demographics except for a higher prevalence of prior abdominal surgeries in the ICG-FI group. Although intraoperative visualization was significantly higher in the ICG-FI group (95.3% vs 89.1%; p = 0.011), the incidence of UI was similar between groups (0.3% vs 0.8%; p = 0.585). Postoperative complications were similar between the two groups. Median stent insertion time was longer in the ICG-FI group (32 vs 25 min; p = 0.001).
CONCLUSION
Ureteric ICG-FI improved intraoperative visualization of the ureters but was not associated with a reduced UI rate. Median stent insertion time increased with use of ureteric ICG-FI, but total operative time did not. Despite its limitations, this study is the largest of its kind suggesting that ureteric ICG-FI may be a valuable adjunct to facilitate ureteric visualization during colorectal surgery
MuPix7 - A fast monolithic HV-CMOS pixel chip for Mu3e
The MuPix7 chip is a monolithic HV-CMOS pixel chip, thinned down to 50 \mu m.
It provides continuous self-triggered, non-shuttered readout at rates up to 30
Mhits/chip of 3x3 mm^2 active area and a pixel size of 103x80 \mu m^2. The hit
efficiency depends on the chosen working point. Settings with a power
consumption of 300 mW/cm^2 allow for a hit efficiency >99.5%. A time resolution
of 14.2 ns (Gaussian sigma) is achieved. Latest results from 2016 test beam
campaigns are shown.Comment: Proceedingsfor the PIXEL2016 conference, submitted to JINST A
dangling reference has been removed from this version, no other change
Prospective Assessment of Sex-Related Differences in Symptom Status and Health Perception Among Patients With Atrial Fibrillation.
We prospectively assessed sex-specific differences in health perception, overall symptom status, and specific symptoms in a large cohort of patients with atrial fibrillation.
We performed a prospective multicenter observational cohort study of 1553 patients with atrial fibrillation. Patients completed questionnaires about personal characteristics, comorbidities, and symptoms on a yearly basis. Mean age was 70±11 years among women and 67±12 years among men. Health perception on a visual analogue scale ranging from 0 to 100 (with higher scores indicating better health perception) was significantly lower in women than in men (70 [interquartile range: 50-80] versus 75 [interquartile range: 60-85]; javax.xml.bind.JAXBElement@29592a5d <0.0001). More women than men had any symptoms (85.0% versus 68.3%; javax.xml.bind.JAXBElement@7ac0b4e4 <0.0001), palpitations (65.2% versus 44.4%; javax.xml.bind.JAXBElement@41229466 <0.0001), dizziness (25.6% versus 13.5%; javax.xml.bind.JAXBElement@61871784 <0.0001), dyspnea (35.7% versus 21.8%; javax.xml.bind.JAXBElement@16cc22b <0.0001), and fatigue (25.3% versus 19.1%; javax.xml.bind.JAXBElement@7ef43176 =0.006). At 1-year follow-up, symptoms decreased in both sexes but remained more frequent in women (49.1% versus 32.6%, javax.xml.bind.JAXBElement@2b200b6a <0.0001). In multivariable adjusted longitudinal regression models, female sex remained an independent predictor for lower health perception (ß=-4.8; 95% CI, -6.5 to -3.1; javax.xml.bind.JAXBElement@72c212bd <0.0001), any symptoms (odds ratio [OR]: 2.6; 95% CI, 2.1-3.4; javax.xml.bind.JAXBElement@15d8fb54 <0.0001), palpitations (OR: 2.6; 95% CI, 2.1-3.2; javax.xml.bind.JAXBElement@4af80718 <0.0001), dizziness (OR: 2.9; 95% CI, 2.1-3.9; javax.xml.bind.JAXBElement@61282e76 <0.0001), dyspnea (OR: 2.1; 95% CI, 1.6-2.8; javax.xml.bind.JAXBElement@31d9f14 <0.0001), fatigue (OR: 1.6; 95% CI, 1.2-2.2; javax.xml.bind.JAXBElement@51cdd678 =0.0008), and chest pain (OR: 1.8; 95% CI, 1.3-2.6; javax.xml.bind.JAXBElement@5b87db9e =0.001).
Women with atrial fibrillation have a substantially higher symptom burden and lower health perception than men. These relationships persisted after multivariable adjustment and during prospective follow-up
Novel bleeding risk score for patients with atrial fibrillation on oral anticoagulants, including direct oral anticoagulants
Objective: Balancing bleeding risk and stroke risk in patients with atrial fibrillation (AF) is a common challenge. Though several bleeding risk scores exist, most have not included patients on direct oral anticoagulants (DOACs). We aimed at developing a novel bleeding risk score for patients with AF on oral anticoagulants (OAC) including both vitamin K antagonists (VKA) and DOACs. Methods: We included patients with AF on OACs from a prospective multicenter cohort study in Switzerland (SWISS-AF). The outcome was time to first bleeding. Bleeding events were defined as major or clinically relevant non-major bleeding. We used backward elimination to identify bleeding risk variables. We derived the score using a point score system based on the β-coefficients from the multivariable model. We used the Brier score for model calibration (<0.25 indicating good calibration), and Harrel's c-statistics for model discrimination. Results: We included 2147 patients with AF on OAC (72.5% male, mean age 73.4 ± 8.2 years), of whom 1209 (56.3%) took DOACs. After a follow-up of 4.4 years, a total of 255 (11.9%) bleeding events occurred. After backward elimination, age > 75 years, history of cancer, prior major hemorrhage, and arterial hypertension remained in the final prediction model. The Brier score was 0.23 (95% confidence interval [CI] 0.19–0.27), the c-statistic at 12 months was 0.71 (95% CI 0.63–0.80). Conclusion: In this prospective cohort study of AF patients and predominantly DOAC users, we successfully derived a bleeding risk prediction model with good calibration and discrimination
Subclinical thyroid function and cardiovascular events in patients with atrial fibrillation
Objective: To evaluate if subclinical thyroid dysfunction is associated with cardiovascular (CV) risk in patients with atrial fibrillation (AF). Methods: Swiss-AF is a prospective cohort of community-dwelling participants aged ≥ 65 years with AF. Primary outcome was a composite endpoint of CV events (myocardial infarctions, stroke/transitory ischemic events, systemic embolism, heart failure (HF) hospitalizations, CV deaths). Secondary outcomes were component endpoints, total mortality, and AF-progression. Exposures were thyroid dysfunction categories, TSH and fT4. Sensitivity analyses were performed for amiodarone use, thyroid hormones use, and competing events. Results: 2415 patients were included (mean age: 73.2 years; 27% women). 196 (8.4%) had subclinical hypothyroidism and 53 (2.3%) subclinical hyperthyroidism. Subclinical thyroid dysfunction was not associated with CV events, during a median follow-up of 2.1 years (max 5 years): age- and sex-adjusted hazard ratio (adjHR) of 0.99 (95% CI: 0.69-1.41) for subclinical hypothyroidism and 0.55 (95% CI: 0.23-1.32) for subclinical hyperthyroidism. Results remained robust following multivariable adjustment and sensitivity analyses. In euthyroid patients, fT4 levels were associated with an increased risk for the composite endpoint and HF (adjHR: 1.46, 95% CI: 1.04-2.05; adjHR: 1.70, 95% CI: 1.08-2.66, respectively, for the highest quintile vs the middle quintile). Results remained similar following multivariable adjustment and remained significant for HF in sensitivity analyses. No association between subclinical thyroid dysfunction and total mortality or AF-progression was found. Conclusions: Subclinical hypothyroidism was not associated with increased CV risk in AF patients. Higher levels of fT4 with normal TSH were associated with a higher risk for HF
Long-term risk of adverse outcomes according to atrial fibrillation type.
Sustained forms of atrial fibrillation (AF) may be associated with a higher risk of adverse outcomes, but few if any long-term studies took into account changes of AF type and co-morbidities over time. We prospectively followed 3843 AF patients and collected information on AF type and co-morbidities during yearly follow-ups. The primary outcome was a composite of stroke or systemic embolism (SE). Secondary outcomes included myocardial infarction, hospitalization for congestive heart failure (CHF), bleeding and all-cause mortality. Multivariable adjusted Cox proportional hazards models with time-varying covariates were used to compare hazard ratios (HR) according to AF type. At baseline 1895 (49%), 1046 (27%) and 902 (24%) patients had paroxysmal, persistent and permanent AF and 3234 (84%) were anticoagulated. After a median (IQR) follow-up of 3.0 (1.9; 4.2) years, the incidence of stroke/SE was 1.0 per 100 patient-years. The incidence of myocardial infarction, CHF, bleeding and all-cause mortality was 0.7, 3.0, 2.9 and 2.7 per 100 patient-years, respectively. The multivariable adjusted (a) HRs (95% confidence interval) for stroke/SE were 1.13 (0.69; 1.85) and 1.27 (0.83; 1.95) for time-updated persistent and permanent AF, respectively. The corresponding aHRs were 1.23 (0.89, 1.69) and 1.45 (1.12; 1.87) for all-cause mortality, 1.34 (1.00; 1.80) and 1.30 (1.01; 1.67) for CHF, 0.91 (0.48; 1.72) and 0.95 (0.56; 1.59) for myocardial infarction, and 0.89 (0.70; 1.14) and 1.00 (0.81; 1.24) for bleeding. In this large prospective cohort of AF patients, time-updated AF type was not associated with incident stroke/SE
- …