893 research outputs found

    Ultrametric probe of the spin-glass state in a field

    Get PDF
    We study the ultrametric structure of phase space of one-dimensional Ising spin glasses with random power-law interaction in an external random field. Although in zero field the model in both the mean-field and non-mean-field universality classes shows an ultrametric signature [Phys. Rev. Lett. 102, 037207 (2009)], when a field is applied ultrametricity seems only present in the mean-field regime. The results for the non-mean field case in an external field agree with data for spin glasses studied within the Migdal-Kadanoff approximation. Our results therefore suggest that the spin-glass state might be fragile to external fields below the upper critical dimension.Comment: 5 pages, 4 figures, 1 tabl

    Magnetoresistance and Structural Characterization of Electrospun La1−xSrxMnO3 Nanowire Networks

    Get PDF
    Nanowire network fabrics of La1−xSrxMnO3 (LSMO) with different doping levels x = 0.2, 0.3, and 0.4 were fabricated by means of electrospinning. The resulting nanowires are up to 100 μm long with a mean diameter of about 230 nm. The nanowires form a nonwoven fabric-like arrangement, allowing to attach electric contacts for magnetoresistance (MR) measurements. The resistance in applied magnetic fields and the MR effect were measured in the temperature range 2 K < T < 300 K in magnetic fields up to 10 T applied perpendicular to the sample surface. An MR ratio of about 70% is obtained for x = 0.2 at 10 T applied field and T = 20 Kr. The highest low-field MR of 5.2% (0.1 T) is obtained for the sample with x = 0.2. Magnetization measurements reveal the soft magnetic character of the samples. A thorough analysis of the microstructure of these nanowire networks is performed including scanning electron microscopy (SEM) and transmission electron microscopy (TEM)

    Matriderm® 1mm versus Integra® Single Layer 1.3mm for one-step closure of full thickness skin defects: a comparative experimental study in rats

    Get PDF
    Purpose: Dermal templates, such as Matriderm® and Integra®, are widely used in plastic and reconstructive surgery, often as two-step procedures. A recent development is the application of thin dermal templates covered with split thickness skin grafts in one-step procedures. In this experimental study, we compare the two thin matrices Matriderm® 1mm and Integra® Single Layer in a one-step procedure with particular focus on neodermis formation. Methods: Matriderm® 1mm and Integra® Dermal Regeneration Template—Single Layer (1.3mm) were compared in a rat model. In three groups of five animals each, a full thickness wound was covered with (a) Matriderm® 1mm and neonatal rat epidermis, (b) Integra® Single Layer and neonatal rat epidermis, or, (c) neonatal rat epidermis only (control). Histological sections 2weeks post transplantation were analyzed with regard to take of template and epidermis, neodermal thickness, collagen deposition, vascularization, and inflammatory response. Results: Take of both templates was complete in all animals. The Matriderm®-based neodermis was thinner but showed a higher cell density than the Integra®-based neodermis. The other parameters were similar in both matrices. Conclusion: The two templates demonstrate a comparable biological behavior early after transplantation. The only difference was found regarding neodermal thickness, probably resulting from faster degradation of Matriderm®. These preliminary data suggest that both dermal templates appear similarly suitable for transplantation in a one-step procedur

    Correlation of passivity symptoms and dysfunctional visuomotor action monitoring in psychosis

    Get PDF
    Passivity experiences are hallmark symptoms of schizophrenia that can be characterized by the belief that one's thoughts or actions are controlled by an external agent. It has recently been suggested that these psychotic experiences result from defective monitoring of one's own actions, i.e. disturbed comparison of actions and perceived outcomes. In this study, we examined the function of the previously characterized action monitoring network of the inferior parietal lobule (IPL), medial (mPFC) and lateral prefrontal cortices in patients with different levels of passivity symptoms with an fMRI task. The visuomotor fMRI task demanded control of visually perceived object movements by alternating button presses with the left and the right index finger. In the monitoring condition of this task subjects stopped their actions whenever they detected visuomotor incongruence. fMRI and behavioural data from 15 patients were tested for correlation with passivity symptoms using standardized Scale for Assessment of Positive Symptoms (SAPS)- and AMDP- passivity symptom ratings. Both types of data were tested for differences between the patients group and 15 healthy controls. In the patient group we found the expected correlation of passivity symptoms and visuomotor monitoring performance. There was a significant positive correlation of passivity symptoms with increased latency of incongruence detection and a negative correlation of SAPS-passivity with the number of detected events. fMRI data revealed correlations of passivity symptoms with activation in bilateral IPL, primary motor and sensory cortices in the action monitoring condition. A correlation of passivity symptoms with the main experimental effect (actions with - actions without monitoring) was found in the posterior cingulate cortex (PCC) and in the left IPL. No group differences or group by task interactions were found within the visuomotor-action-monitoring network. Our results demonstrate the association between passivity symptoms and the dysfunction of visuomotor action monitoring and support the idea that psychotic passivity experiences result from dysfunctions of central action monitoring mechanisms: According to pre-existing concepts of parietal cortex function, IPL-hyperactivation may represent an increase in false detections of visuomotor incongruence while the correlation between passivity and the differential effect of monitoring on PCC-activation assumedly represents greater self-monitoring effort in passivity experience

    Correlation of passivity symptoms and dysfunctional visuomotor action monitoring in psychosis

    Get PDF
    Passivity experiences are hallmark symptoms of schizophrenia that can be characterized by the belief that one's thoughts or actions are controlled by an external agent. It has recently been suggested that these psychotic experiences result from defective monitoring of one's own actions, i.e. disturbed comparison of actions and perceived outcomes. In this study, we examined the function of the previously characterized action monitoring network of the inferior parietal lobule (IPL), medial (mPFC) and lateral prefrontal cortices in patients with different levels of passivity symptoms with an fMRI task. The visuomotor fMRI task demanded control of visually perceived object movements by alternating button presses with the left and the right index finger. In the monitoring condition of this task subjects stopped their actions whenever they detected visuomotor incongruence. fMRI and behavioural data from 15 patients were tested for correlation with passivity symptoms using standardized Scale for Assessment of Positive Symptoms (SAPS)- and AMDP- passivity symptom ratings. Both types of data were tested for differences between the patients group and 15 healthy controls. In the patient group we found the expected correlation of passivity symptoms and visuomotor monitoring performance. There was a significant positive correlation of passivity symptoms with increased latency of incongruence detection and a negative correlation of SAPS-passivity with the number of detected events. fMRI data revealed correlations of passivity symptoms with activation in bilateral IPL, primary motor and sensory cortices in the action monitoring condition. A correlation of passivity symptoms with the main experimental effect (actions with – actions without monitoring) was found in the posterior cingulate cortex (PCC) and in the left IPL. No group differences or group by task interactions were found within the visuomotor-action-monitoring network. Our results demonstrate the association between passivity symptoms and the dysfunction of visuomotor action monitoring and support the idea that psychotic passivity experiences result from dysfunctions of central action monitoring mechanisms: According to pre-existing concepts of parietal cortex function, IPL-hyperactivation may represent an increase in false detections of visuomotor incongruence while the correlation between passivity and the differential effect of monitoring on PCC-activation assumedly represents greater self-monitoring effort in passivity experiences

    Diagnostik und Therapie von Lebermetastasen bei kolorektalem Primärtumor

    Get PDF
    Contrast-enhanced multislice computer tomography (MSCT) has established itself as the standard tomographic imaging method both for diagnosis and for treatment monitoring of hepatic lesions. To clarify local conditions before partial liver resection, diffusion-weighted magnetic resonance tomography (DWI-MRT) can also provide important additional information. In order to meet the criteria for a R0 resection, a margin of 0.5 mm seems to be sufficient. Neoadjuvant chemotherapy aiming to reduce tumour size can be given in parallel with portal artery embolisation without adversely affecting perioperative morbidity and mortality. As far as the management of primary resectable liver metastases is concerned, there is an urgent need for more studies. Despite the relatively limited evidence, adjuvant chemotherapy is currently more widely favoured in Germany than perioperative chemotherapy. There is also considerable need for studies concerning preoperative therapy in patients with liver metastases that are not (yet) resectable. In KRAS wild-type tumours, high response rates (in terms of a reduction in the size of metastases) are achieved with a cetuximab/chemotherapy combination. Bevacizumab/chemotherapy combinations lead to high rates of pathohistological complete and partial remissions. What the best parameter for judging the success of preoperative therapy is remains unknown, and so comparison studies using survival as a `hard' endpoint must be carried out

    µFBI: A Microfluidic Bead-Based Immunoassay for Multiplexed Detection of Proteins from a µL Sample Volume

    Get PDF
    BACKGROUND: Over the last ten years, miniaturized multiplexed immunoassays have become robust, reliable research tools that enable researchers to simultaneously determine a multitude of parameters. Among the numerous analytical protein arrays available, bead-based assay systems have evolved into a key technology that enables the quantitative protein profiling of biological samples whilst requiring only a minimal amount of sample material. METHODOLOGY/PRINCIPAL FINDINGS: A microfluidic bead-based immunoassay, µFBI, was developed to perform bead-based multiplexed sandwich immunoassays in a capillary. This setup allows the simultaneous detection of several parameters and only requires 200 ng of tissue lysate in a 1 µL assay volume. In addition, only 1 µL of detection antibodies and 1 µL of the reporter molecule Streptavidin-Phycoerythrin were required. The µFBI was used to compare the expression of seven receptor tyrosine kinases and their degree of tyrosine phosphorylation in breast cancer tissue and in normal tissue lysates. The total amount of HER-2, as well the degree of tyrosine phosphorylation was much higher in breast cancer tissue than in normal tissue. µFBI and a standard bead-based assay led to identical protein expression data. Moreover, it was possible to reduce the quantity of sample material required by a factor of 100 and the quantity of reagents by a factor of 30. CONCLUSIONS/SIGNIFICANCE: The µFBI, microfluidic bead-based immunoassay, allows the analysis of multiple parameters from a very small amount of sample material, such as tumor biopsies or tissue sections

    MHD turbulence in a channel with spanwise magnetic field

    Full text link
    The effect of a uniform spanwise magnetic field on a turbulent channel flow is investigated for the case of low magnetic Reynolds number. DNS and LES computations are performed for two values of the hydrodynamic Reynolds number (10^4 and 2\times 10^4) and the Hartmann number varying in a wide range. It is shown that the main effect of the magnetic field is the suppression of turbulent velocity fluctuations and momentum transfer in the wall-normal direction. This leads to drag reduction and transformation of the mean flow profile. The centerline velocity grows, the mean velocity gradients near the wall decrease, and the typical horizontal dimensions of the coherent structures enlarge upon increasing the Hartmann number. Comparison between LES and DNS results shows that the dynamic Smagorinsky model accurately reproduces the flow transformation.Comment: 27 pages, 14 Postscript figures, to appear in Phys. Fluid

    I-BEAT: New ultrasonic method for single bunch measurement of ion energy distribution

    Full text link
    The shape of a wave carries all information about the spatial and temporal structure of its source, given that the medium and its properties are known. Most modern imaging methods seek to utilize this nature of waves originating from Huygens' principle. We discuss the retrieval of the complete kinetic energy distribution from the acoustic trace that is recorded when a short ion bunch deposits its energy in water. This novel method, which we refer to as Ion-Bunch Energy Acoustic Tracing (I-BEAT), is a generalization of the ionoacoustic approach. Featuring compactness, simple operation, indestructibility and high dynamic ranges in energy and intensity, I-BEAT is a promising approach to meet the needs of petawatt-class laser-based ion accelerators. With its capability of completely monitoring a single, focused proton bunch with prompt readout it, is expected to have particular impact for experiments and applications using ultrashort ion bunches in high flux regimes. We demonstrate its functionality using it with two laser-driven ion sources for quantitative determination of the kinetic energy distribution of single, focused proton bunches.Comment: Paper: 17 Pages, 3 figures Supplementary Material 16 pages, 7 figure
    • …
    corecore