90 research outputs found

    European Multicenter Study for the Evaluation of a Dual-Layer Flow-Diverting Stent for Treatment of Wide-Neck Intracranial Aneurysms: The European Flow-Redirection Intraluminal Device Study

    Get PDF
    BACKGROUND AND PURPOSE: Endoluminal reconstruction with flow-diverting stents represents a widely accepted technique for the treatment of complex intracranial aneurysms. This European registry study analyzed the initial experience of 15 neurovascular centers with the Flow-Redirection Intraluminal Device (FRED) system. MATERIALS AND METHODS: Consecutive patients with intracranial aneurysms treated with the FRED between February 2012 and March 2015 were retrospectively reviewed. Complications and adverse events, transient and permanent morbidity, mortality, and occlusion rates were evaluated. RESULTS: During the defined study period, 579 aneurysms in 531 patients (median age, 54 years;range, 13-86 years) were treated with the FRED. Seven percent of patients were treated in the acute phase (3 days) of aneurysm rupture. The median aneurysm size was 7.6 mm (range, 1-36.6 mm), and the median neck size 4.5 mm (range, 1-30 mm). Angiographic follow-up of >3 months was available for 516 (89.1%) aneurysms. There was progressive occlusion witnessed with time, with complete occlusion in 18 (20%) aneurysms followed for up to 90 14 days, 141 (82.5%) for 180 +/- 20 days, 116 (91.3%) for 1 year +/- 24 days, and 122 (95.3%) aneurysms followed for >1 year. Transient and permanent morbidity occurred in 3.2% and 0.8% of procedures, respectively. The overall mortality rate was 1.5%. CONCLUSIONS: This retrospective study in real-world patients demonstrated the safety and efficacy of the FRED for the treatment of intracranial aneurysms. In most cases, treatment with a single FRED resulted in complete angiographic occlusion at 1 year

    Endovascular interventions in spinal cord

    No full text

    Effect of boron on micro structure and microhardness properties of Mo-Si-B based coatings produced viatig process

    No full text
    In this study, Mo-Si-B based coatings were produced using tungsten inert gas (TIG) process on the medium carbon steel because the physical, chemical, and mechanical properties of these alloys are particularly favourable for high-temperature structural applications. It is aimed to investigate of microstructure and microhardness properties of Mo-Si-B based coatings. Optical microscopy (OM), X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the microstructures of Mo-Si-B based coatings. The XRD results showed that microstructure of Mo-Si-B coating consists of α-Mo, α-Fe, Mo2B, Mo3Si and Mo5SiB2 phases. It was reported that the grains in the niicrostructure were finer with increasing amounts of boron which caused to occur phase precipitations in the grain boundary. Besides, the average microhardness of coatings changed between 735 HV0.3 and 1140 HV0.3 depending on boron content

    Flow Re-direction Endoluminal Device in treatment of cerebral aneurysms: initial experience with short-term follow-up results

    No full text
    Object. Flow diverter (FD) stents are relatively new and important devices in the treatment of cerebral aneurysms. The Flow Re-Direction Endoluminal Device has been recently released for clinical use. The authors' aim in this paper is to report their initial single-center FRED experience with short-term results

    PERSISTENT NONMIGRATED VENTRAL PRIMITIVE OPHTHALMIC ARTERY - REPORT ON ONE CASE

    No full text
    A case of aberrant anterior cerebral artery origin of the ophthalmic artery is presented. This indubitable radiological demonstration of such variation highlights some hypothetic steps in the embryogenesis of the ophthalmic artery

    Endovascular coil embolization of residual or recurrent aneurysms after surgical clipping

    No full text
    Purpose: Treatment of residual or recurrent aneurysms after surgical clipping is a challenge and most surgeons prefer to avoid a second surgical attempt. We present treatment of 4 residual or recurrent aneurysms after surgical clipping with electrolytically detachable coils
    corecore