31,668 research outputs found
A new method of alpha ray measurement using a Quadrupole Mass Spectrometer
We propose a new method of alpha()-ray measurement that detects
helium atoms with a Quadrupole Mass Spectrometer(QMS). A demonstration is
undertaken with a plastic-covered Am -emitting source to detect
-rays stopped in the capsule. We successfully detect helium atoms that
diffuse out of the capsule by accumulating them for one to 20 hours in a closed
chamber. The detected amount is found to be proportional to the accumulation
time. Our method is applicable to probe -emitting radioactivity in bulk
material.Comment: 8 pages, 6 figure
Influence of magnetic impurities on charge transport in diffusive-normal-metal / superconductor junctions
Charge transport in the diffusive normal metal (DN) / insulator / - and -wave superconductor junctions is studied in the presence of magnetic
impurities in DN in the framework of the quasiclassical Usadel equations with
the generalized boundary conditions. The cases of - and d-wave
superconducting electrodes are considered. The junction conductance is
calculated as a function of a bias voltage for various parameters of the DN
metal: resistivity, Thouless energy, the magnetic impurity scattering rate and
the transparency of the insulating barrier between DN and a superconductor. It
is shown that the proximity effect is suppressed by magnetic impurity
scattering in DN for any value of the barrier transparency. In low-transparent
s-wave junctions this leads to the suppression of the normalized zero-bias
conductance. In contrast to that, in high transparent junctions zero-bias
conductance is enhanced by magnetic impurity scattering. The physical origin of
this effect is discussed. For the d-wave junctions, the dependence on the
misorientation angle between the interface normal and the crystal axis
of a superconductor is studied. The zero-bias conductance peak is suppressed by
the magnetic impurity scattering only for low transparent junctions with
. In other cases the conductance of the d-wave junctions does
not depend on the magnetic impurity scattering due to strong suppression of the
proximity effect by the midgap Andreev resonant states.Comment: 11 pages, 13 figures;d-wave case adde
An x-ray detector using PIN photodiodes for the axion helioscope
An x-ray detector for a solar axion search was developed. The detector is
operated at 60K in a cryostat of a superconducting magnet. Special care was
paid to microphonic noise immunity and mechanical structure against thermal
contraction. The detector consists of an array of PIN photodiodes and tailor
made preamplifiers. The size of each PIN photodiode is $11\times 11\times 0.5\
{\rm mm^3}$ and 16 pieces are used for the detector. The detector consists of
two parts, the front-end part being operated at a temperature of 60K and the
main part in room temperature. Under these circumstances, the detector achieved
1.0 keV resolution in FWHM, 2.5 keV threshold and 6\times 10^{-5} counts
sec^{-1} keV^{-1} cm^{-2} background level.Comment: 8 pages, 5 figures, submitted to Nucl. Instr. Meth.
- …
