9 research outputs found

    Interpreting Quality-of-Life Questionnaires in Patients with Long-Standing Facial Palsy

    Get PDF
    Objective(s): To interpret change in quality-of-life scores in facial palsy patients by calculating the smallest detectable change (SDC) and minimal important change (MIC) for the Facial Disability Index (FDI), Facial Clinimetric Evaluation (FaCE) scale, and Synkinesis Assessment Questionnaire (SAQ). Materials and Methods: The SDC, for individuals and groups, was calculated using previously collected test-retest data (2-week interval). The MIC (predictive modeling method) was calculated in a second similar facial palsy population using two measurements (1-1.5-year interval) and an anchor question assessing perceived change. Results: SDC(individual) of FaCE was 17.6 and SAQ was 28.2. SDC(group) of FaCE was 2.9 and SAQ was 4.6 (n = 62). Baseline FaCE and SAQ scores were 43.3 (interquartile range [IQR]: 35.8;55.0) and 51.1 (IQR: 32.2;60.0), respectively. MIC for important improvement of FDI physical/social function, FaCE total, and SAQ total were 4.4, 0.4, 0.7, and 2.8, respectively (n = 88). MIC for deterioration was 8.2, -1.8, -8.5, and 0.6, respectively. Baseline scores were 70.0 (IQR: 60.0;80.0), 76.0 (68.0;88.0), 55.0 (IQR: 40.0;61.7), and 26.7 (IQR: 22.2;35.6), respectively. Number of participants reporting important change for the different questionnaires ranged from 3 to 23 per subscale. Conclusion: Interpreting change scores of the FDI, FaCE, and SAQ is appropriate for groups, but for individual patients it is limited by a substantial SDC

    A cross-sectional analysis of facial palsy-related quality of life in 125 patients: Comparing linear, quadratic and cubic regression analyses

    Get PDF
    Introduction: Facial function correlates with quality of life in facial palsy. Previous studies have examined a linear relationship; based on clinical experience, we hypothesize a curved regression (i.e. quadratic or cubic) will be more fitting to show the correlation between quality of life and facial function. Methods: We compared the fit of a linear regression model between Sunnybrook scores (facial function) and FaCE and FDI scores (quality of life) to a quadratic and cubic regression model in 125 patients cross-sectionally. Results: A total of 125 patients were included, 53.6% female with a mean (standard deviation) age of 56.6 (16.7) and a median (interquartile range) duration of palsy of 6.6 (1.5; 18.3) years. The quadratic regression proved a significant improvement over a linear regression analysis in the model using the FaCE total score (linear R2 =.346, quadratic R2 = .378, p = .033) and the FDI physical score (linear R2 = .245, quadratic R2 =.276, p = .034). The cubic regression analysis was no significant improvement over a quadratic regression. Discussion: The relationship between facial function and quality of life in facial palsy is not linear meaning that there is a lot of variation in QoL in cases with severe and moderate facial impairment. This is most applicable to patients suffering from post-paralysis synkinesis, proving the highly individually experienced burden of synkinesis. As the relationship is not linear it should not be included as such in future research studies

    Reliability and Agreement of 3D Anthropometric Measurements in Facial Palsy Patients Using a Low-Cost 4D Imaging System

    No full text
    The reliability (precision) and agreement (accuracy) of anthropometric measurements based on manually placed 3D landmarks using the RealSense D415 were investigated in this paper. Thirty facial palsy patients, with their face in neutral (resting) position, were recorded simultaneously with the RealSense and a professional 3dMD imaging system. First the RealSense depth accuracy was determined. Subsequently, two observers placed 14 facial landmarks on the 3dMD and RealSense image, assessing the distance between landmark placement. The respective intra- and inter-rater Euclidean distance between the landmark placements was 0.84 mm (±0.58) and 1.00 mm (±0.70) for the 3dMD landmarks and 1.32 mm (±1.27) and 1.62 mm (±1.42) for the RealSense landmarks. From these landmarks 14 anthropometric measurements were derived. The intra- and inter-rater measurements had an overall reliability of 0.95 (0.87 - 0.98) and 0.93 (0.85 - 0.97) for the 3dMD measurements, and 0.83 (0.70 - 0.91) and 0.80 (0.64 - 0.89) for the RealSense measurements, respectively, expressed as the intra-class correlation coefficient. Determined by the Bland-Altman analysis, the agreement between the RealSense measurements and 3dMD measurements was on average -0.90 mm (-4.04 - 2.24) and -0.89 mm (-4.65 - 2.86) for intra- and inter-rater agreement, respectively. Based on the reported reliability and agreement of the RealSense measurements, the RealSense D415 can be considered as a viable option to perform objective 3D anthropomorphic measurements on the face in a neutral position, where a low-cost and portable camera is required

    An overview of surgical techniques and non-surgical treatments in lifting the eyebrow including current treatments available

    No full text
    The eyebrow is a complex structure of the human face, which has both functional (communication) and aesthetic aspects and contributes to a persons' individual appearance. Ptosis of the eyebrow is a common condition, especially among the elderly and smokers. Facial appearance is disrupted by eyebrow ptosis, and in many cases, correction and treatment are needed. No specific type of browlift has been shown to be superior to another, and since there is a wide variation in treatment preference between patients, it requires an individual approach to each specific patient. This review provides an overview of the history of the browlift, non-surgical treatment and current surgical techniques available. Level of evidence: Not ratable

    Vaginal expression of efflux transporters and the potential impact on the disposition of microbicides in vitro and in rabbits

    No full text
    In order to reach sufficiently high tissue concentrations and thus be effective, vaginally applied anti-HIV microbicides that are active at the level of the immune cells must permeate across the cervicovaginal mucosal layer. Cellular efflux transporters, such as Pgp, BCRP, and MRP-2, have been demonstrated to greatly affect drug disposition at different sites in the body including the intestine and the blood-brain barrier; their possible role on drug uptake from the female genital tract, however, has not been elucidated yet. In the present study, the protein expression of Pgp, BCRP, and MRP-2 in endocervical and vaginal tissue of premenopausal women was confirmed by Western blot analysis. To enable the assessment of transporter effects in vitro, the identification of an appropriate cervicovaginal cell line was pursued. The cervical SiHa cell line was observed to express mRNA of the 3 studied transporters, but only MRP-2 was found to be active. Consequently, the established Caco-2 cell line was utilized as an alternative in which the interaction of 10 microbicide candidates with the efflux transporters was studied. Darunavir, saquinavir, and maraviroc were identified as Pgp and MRP-2 substrates. The impact of Pgp on in vivo drug disposition was further examined for the model Pgp substrate talinolol in rabbits. Its vaginal uptake was significantly reduced by Pgp-mediated efflux when formulated in a neutral but not in an acidic gel. Our findings indicate the expression of a functional Pgp transporter in the vaginal mucosa that may severely reduce the vaginal uptake of Pgp substrates, including certain microbicide candidates, especially in women with an increased vaginal pH
    corecore