1,000 research outputs found
Management of an Accessory Bile Duct Leak Following Pancreaticoduodenectomy: A Novel Approach Utilizing a Percutaneous and Endoscopic Rendezvous.
Biliary leaks are uncommon but morbid complications of pancreaticoduodenectomies, which have historically been managed with percutaneous drainage, reoperation, or a combination of both. We report a de novo percutaneous-endoscopic hepaticojejunostomy from an anomalous right hepatic duct injured during pancreaticoduodenectomy to the afferent bowel limb. The percutaneous-endoscopic hepaticojejunostomy was stented to allow for tract formation with successful stent removal after 5.5 months. One year after the creation of the percutaneous-endoscopic hepaticojejunostomy, the patient remains clinically well without evidence of biliary leak or obstruction
Replica symmetry breaking transition of the weakly anisotropic Heisenberg spin glass in magnetic fields
The spin and the chirality orderings of the three-dimensional Heisenberg spin
glass with the weak random anisotropy are studied under applied magnetic fields
by equilibrium Monte Carlo simulations. A replica symmetry breaking transition
occurs in the chiral sector accompanied by the simultaneous spin-glass order.
The ordering behavior differs significantly from that of the Ising SG, despite
the similarity in the global symmetry. Our observation is consistent with the
spin-chirality decoupling-recoupling scenario of a spin-glass transition.Comment: 4 pages, 4 figure
Gd-EOB-DTPA-Enhanced MRI for Detection of Liver Metastases from Colorectal Cancer: A Surgeonās Perspective!
Colorectal cancer affects over one million people worldwide annually, with the liver being the most common site of metastatic spread. Adequate resection of hepatic metastases is the only chance for a cure in a subset of patients, and five-year survival increases to 35% with complete resection. Traditionally, computed tomographic imaging (CT) was utilized for staging and to evaluate metastases in the liver. Recently, the introduction of hepatobiliary contrast-enhanced magnetic resonance imaging (MRI) agents including gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Eovist in the United States, Primovist in Europe, or Gd-EOB-DTPA) has proved to be a sensitive method for detection of hepatic metastases. Accurate detection of liver metastases is critical for staging of colorectal cancer as well as preoperative planning
Ordering of the Heisenberg Spin Glass in High Dimensions
Ordering of the Heisenberg spin glass with the nearest-neighbor Gaussian
coupling is investigated by equilibrium Monte Carlo simulations in four and
five dimensions. Ordering of the mean-field Heisenberg spin-glass is also
studied for comparison. Particular attention is paid to the nature of the
spin-glass and the chiral-glass orderings. Our numerical data suggest that, in
five dimensions, the model exhibits a single spin-glass transition at a finite
temperature, where the spin-glass order accompanying the simultaneous
chiral-glass order sets in. In four dimensions, by contrast, the model exhibits
a chiral-glass transition at a finite temperature, not accompanying the
standard spin-glass order. The critical region associated with the chiral-glass
transition, however, is very narrow, suggesting that dimension four is close to
the marginal dimensionality.Comment: 18 pages, 12 figure
Ordering of the three-dimensional Heisenberg spin glass in magnetic fields
Spin and chirality orderings of the three-dimensional Heisenberg spin glass
are studied under magnetic fields in light of the recently developed
spin-chirality decoupling-recoupling scenario. It is found by Monte Carlo
simulations that the chiral-glass transition and the chiral-glass ordered
state, which are essentially of the same character as their zero-field
counterparts, occur under magnetic fields. Implication to experimental phase
diagram is discussed.Comment: 5 pages, 3 figure
"Glassy Dynamics" in Ising Spin Glasses -- Experiment and Simulation
The field-cooled magnetization (FCM) processes of Ising spin glasses under
relatively small fields are investigated by experiment on
Fe_{0.55}Mn_{0.45}TiO_3 and by numerical simulation on the three-dimensional
Edwards-Anderson model. Both results are explained in a unified manner by means
of the droplet picture. In particular, the cusp-like behavior of the FCM is
interpreted as evidence, not for an equilibrium phase transition under a finite
magnetic field, but for a dynamical (`blocking') transition frequently observed
in glassy systems.Comment: 4 pages, 7 figure
Dynamical Critical Phenomena in three-dimensional Heisenberg Spin Glasses
Spin-glass (SG) and chiral-glass (CG) orderings in three dimensional (3D)
Heisenberg spin glass with and without magnetic anisotropy are studied by using
large-scale off-equilibrium Monte Carlo simulations. A characteristic time of
relaxation, which diverges at a transition temperature in the thermodynamic
limit, is obtained as a function of the temperature and the system size. Based
on the finite-size scaling analysis for the relaxation time, it is found that
in the isotropic Heisenberg spin glass, the CG phase transition occurs at a
finite temperature, while the SG transition occurs at a lower temperature,
which is compatible with zero. Our results of the anisotropic case support the
chirality scenario for the phase transitions in the 3D Heisenberg spin glasses.Comment: 9 pages, 19 figure
Monte Carlo studies of the ordering of the one-dimensional Heisenberg spin glass with long-range power-law interactions
The nature of the ordering of the one-dimensional Heisenberg spin-glass model
with a long-range power-law interaction is studied by extensive Monte Carlo
simulations, with particular attention to the issue of the spin-chirality
decoupling/coupling. Large system sizes up to are studied. With
varying the exponent describing the power-law interaction, we observe
three distinct types of ordering regimes. For smaller , the spin and
the chirality order at a common finite temperature with a common
correlation-length exponent, exhibiting the standard spin-chirality coupling
behavior. For intermediate , the chirality orders at a temperature
higher than the spin, exhibiting the spin-chirality decoupling behavior. For
larger , both the spin and the chirality order at zero temperature. We
construct a phase diagram in the versus the temperature plane, and
discuss implications of the results. Critical properties associated with both
the chiral-glass and the spin-glass transitions are also determined.Comment: 28 pages, 26 figures, to appear in J. Phys. Soc. Jp
Improved detectability of small-bowel lesions via capsule endoscopy with computed virtual chromoendoscopy: A pilot study
Objective. Real-time video capsule endoscopy (CE) with flexible spectral imaging color enhancement (FICE) improves visibility of small-bowel lesions. This article aims to clarify whether CE-FICE also improves detectability of small-bowel lesions. Patients and methods. A total of 55 patients who underwent CE at Hiroshima University Hospital during the period November 2009 through March 2010 were enrolled in the study. Five patients were excluded from the study because residues and transit delays prevented sufficient evaluation. Thus, 50 patients participated. Two experienced endoscopists (each having interpreted more than 50 capsule videos) analyzed the images. One interpreted conventional capsule videos; the other, blinded to interpretation of the conventional images, interpreted CE-FICE images obtained at settings 1-3 (setting 1: red 595 nm, green 540 nm, blue 535 nm; setting 2: red 420 nm, green 520 nm, blue 530 nm; setting 3: red 595 nm, green 570 nm, blue 415 nm). Lesions were classified as angioectasia, erosion, ulceration, or tumor. Detectability was compared between the two modalities. Time taken to interpret the capsule videos was also determined. Results. Seventeen angioectasias were identified by conventional CE; 48 were detected by CE-FICE at setting 1, 45 at setting 2, and 24 at setting 3, with significant differences at settings 1 and 2 (p = 0.0003, p < 0.0001, respectively). Detection of erosion, ulceration, and tumor did not differ statistically between conventional CE and CE-FICE, nor did interpretation time (conventional CE 36 Ā± 6.9 min; CE-FICE setting 1, 36 Ā± 6.4 min; setting 2, 38 Ā± 5.8 min; setting 3, 35 Ā± 6.7 min). Conclusions. CE-FICE is superior in the lesion detection in comparison with conventional CE and improves detection of angioectasia
- ā¦