10 research outputs found

    Polymerization time for a microwave-cured acrylic resin with multiple flasks Tempo de polimerização de resina acrílica em microondas, utilizando múltiplas muflas

    No full text
    This study aimed at establishing the polymerization time of a microwave-cured acrylic resin (AcronTM MC), simultaneously processing 2, 4, and 6 flasks. Required time was measured according to the parameters: monomer release in water, Knoop hardness, and porosity. Samples were made with AcronTM MC in different shapes: rectangular (32 x 10 x 2.5 mm) for monomer release and porosity; and half-disc (30 mm in diameter x 4 mm in height) for Knoop hardness. There were four experimental groups (n = 24 per group): G1) one flask (control); G2) two flasks; G3) four flasks, and G4) six flasks. At first, polymerization protocol was similar for all groups (3 min/450 W). Time was then adjusted for G2, G3, and G4, based on monomer release evaluation in the control group, obtained by spectrophotometer Beckman DU-70, with emitting wave of 206 nm. Knoop hardness test was performed using a Shimadzu HMV 2000 hardness tester, and 10 indentations were performed on each specimen's surface. Porosity was assessed after specimens were immersed in black ink and the pores counted in a microscope. Results showed that the complete polymerization of the resin occurred in 4.5 min for two flasks (G2); 8.5 min for four flasks (G3); and 13 min for six flasks (G4), all with 450 W. Statistical analysis revealed that the number of flasks does not interfere with polymerization, Knoop hardness, and porosity of the resin. Results showed that polymerization of microwave-curing resin with more than one flask is a viable procedure, as long as polymerization time is adjusted.<br>O objetivo deste estudo foi o de determinar os tempos necessários para a polimerização padrão de uma resina acrílica em microondas, utilizando várias muflas simultaneamente. Os tempos necessários foram aferidos por parâmetros como monômeros liberados em água, dureza Knoop e porosidade. As amostras, confeccionadas em resina AcronTM MC, apresentavam as seguintes dimensões: para os parâmetros monômero residual e porosidade, retângulos de 32 x 10 x 2,5 mm e, para dureza superficial Knoop, semidiscos de 30,0 mm de diâmetro e 4,0 mm de espessura. As mensurações foram realizadas em quatro grupos (24 amostras cada): G1 - uma mufla (controle); G2 - duas muflas; G3 - quatro muflas; e G4 - seis muflas no forno de microondas, respectivamente. Inicialmente, o mesmo protocolo de polimerização foi utilizado para todos os grupos: 3 minutos a 450 W. Em seguida, o tempo de polimerização foi ajustado para os grupos 2, 3 e 4, usando como padrão os resultados do grupo 1 obtidos na análise do monômero liberado em água em espectrofotômetro Beckman DU-70, com comprimento de onda de 206 nm. Para a determinação da dureza Knoop, 10 endentações foram realizadas em cada espécime, utilizando microdurômetro Shimadzu HMV-2000. A porosidade foi avaliada após a imersão das amostras em tinta nanquim preta, contando-se os poros em microscópio. Os tempos necessários para a polimerização da resina AcronTM MC foram: 4,5 minutos para duas muflas; 8,5 minutos para quatro muflas e 13 minutos para seis muflas. De acordo com os resultados, a polimerização de resina em microondas, utilizando mais de uma mufla no forno, é um procedimento viável, desde que os tempos de polimerização sejam ajustados

    Effect of post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins Efeito de tratamentos térmicos após a polimerização sobre a citotoxicidade de duas resinas acrílicas para base de próteses

    Get PDF
    INTRODUCTION: Most denture base acrylic resins have polymethylmethacrylate in their composition. Several authors have discussed the polymerization process involved in converting monomer into polymer because adequate polymerization is a crucial factor in optimizing the physical properties and biocompatibility of denture base acrylic resins. To ensure the safety of these materials, in vitro cytotoxicity assays have been developed as preliminary screening tests to evaluate material biocompatibility. ³H-thymidine incorporation test, which measures the number of cells synthesizing DNA, is one of the biological assays suggested for cytotoxicity testing. AIM: The purpose of this study was to investigate, using ³H-thymidine incorporation test, the effect of microwave and water-bath post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins. MATERIALS AND METHODS: Nine disc-shaped specimens (10 x 1 mm) of each denture base resin (Lucitone 550 and QC 20) were prepared according to the manufacturers' recommendations and stored in distilled water at 37ºC for 48 h. The specimens were assigned to 3 groups: 1) post-polymerization in a microwave oven for 3 min at 500 W; 2) post-polymerization in water-bath at 55º C for 60 min; and 3) without post-polymerization. For preparation of eluates, 3 discs were placed into a sterile glass vial with 9 mL of Eagle's medium and incubated at 37ºC for 24 h. The cytotoxic effect of the eluates was evaluated by ³H-thymidine incorporation. RESULTS: The results showed that the components leached from the resins were cytotoxic to L929 cells, except for the specimens heat treated in water bath (p<0.05). Compared to the group with no heat treatment, water-bath decreased the cytotoxicity of the denture base acrylic resins. CONCLUSION: The in vitro cytotoxicity of the tested denture base materials was not influenced by microwave post-polymerization heat treatment.<br>INTRODUÇÃO: A maioria das resinas acrílicas utilizadas para confecção de bases de próteses é composta pelo polimetacilato de metila. Muitos autores têm discutido o processo de polimerização dessas resinas em relação à conversão do monômero em polímero devido a sua importância na melhora da biocompatibilidade e das propriedades físicas. Para assegurar a utilização desses materiais, testes preliminares de citotoxicidade in vitro têm sido desenvolvidos para avaliação da biocompatibilidade. Um dos ensaios biológicos sugeridos para a análise da citotoxicidade é o teste de incorporação de ³H-timidina, o qual mede o número de células por meio da síntese de DNA. OBJETIVO: O objetivo do presente estudo foi avaliar, por meio do teste de incorporação de ³H-timidina, a citotoxicidade de duas resinas acrílicas para base de próteses submetidas aos tratamentos em microondas e em banho de água após a polimerização. MATERIAL E MÉTODO: Nove corpos-de-prova em forma de discos (10 x 1 mm) foram confeccionados com as resinas acrílicas Lucitone 550 e QC 20 de acordo com as instruções dos fabricantes, e foram armazenados em água destilada a 37ºC por 48 h. Os corpos-de-prova foram divididos em três grupos: 1) tratamento em forno de microondas por 3 min a 500 W; 2) tratamento em banho de água a 55ºC por 60 min; e 3) sem tratamento térmico. Extratos foram preparados pela colocação de 3 discos em tubos de ensaio estéreis com 9 mL de meio de cultura Eagle e incubação a 37ºC por 24 h. O efeito citotóxico dos extratos foi avaliado utilizando o teste de incorporação de ³H-timidina. RESULTADOS: Os resultados indicaram que os componentes liberados pelas resinas foram citotóxicos para as células L929 exceto para as amostras tratadas em banho de água (p<0.05). Em comparação com o grupo sem tratamento, o banho de água diminuiu a citotoxicidade das resinas acrílicas. CONCLUSÃO: O tratamento em microondas não influenciou a citotoxicidade das resinas acrílicas para bases de próteses
    corecore