288 research outputs found

    A Passivity-based Nonlinear Admittance Control with Application to Powered Upper-limb Control under Unknown Environmental Interactions

    Get PDF
    This paper presents an admittance controller based on the passivity theory for a powered upper-limb exoskeleton robot which is governed by the nonlinear equation of motion. Passivity allows us to include a human operator and environmental interaction in the control loop. The robot interacts with the human operator via F/T sensor and interacts with the environment mainly via end-effectors. Although the environmental interaction cannot be detected by any sensors (hence unknown), passivity allows us to have natural interaction. An analysis shows that the behavior of the actual system mimics that of a nominal model as the control gain goes to infinity, which implies that the proposed approach is an admittance controller. However, because the control gain cannot grow infinitely in practice, the performance limitation according to the achievable control gain is also analyzed. The result of this analysis indicates that the performance in the sense of infinite norm increases linearly with the control gain. In the experiments, the proposed properties were verified using 1 degree-of-freedom testbench, and an actual powered upper-limb exoskeleton was used to lift and maneuver the unknown payload.Comment: Accepted in IEEE/ASME Transactions on Mechatronics (T-MECH

    Epileptic nystagmus: A case report and systematic review

    Get PDF
    AbstractPurposeWe aimed to define the characteristics of epileptic nystagmus and correlate those with other clinical findings in a large number of patients.MethodsWe report a patient with epileptic nystagmus and additionally reviewed the reported clinical features of 36 more patients through a systematic literature search. We analyzed the characteristics of epileptic nystagmus and attempted correlations of those with alertness of the patients and epileptic foci on EEG.ResultsAll 33 patients with unilateral horizontal nystagmus showed nystagmus beating away from the side of ictal discharges. Epileptic nystagmus was preceded by gaze deviation in 21 patients, with contraversive in 19 and ipsiversive in 2. Seizures associated with epileptic nystagmus were mostly focal (25/29, 86.2%) with or without loss of awareness. Ictal discharges originated from the occipital (n=16), parietal (n=9), temporo-occipital (n=6), frontal (n=4), and temporal (n=3) areas, and two patients had multiple epileptic foci. Seizures were usually symptomatic (24/37, 64.9%). The presence of preceding gaze deviation and midline crossing of the nystagmus did not correlate with the ictal onset zone or alertness of the patients. Recording of epileptic nystagmus was available only in 6 patients, and the epileptic nystagmus could be localized to the saccadic areas in two and to the smooth pursuit areas in another two. Two patients showed the features of epileptic nystagmus from both areas.ConclusionEven though the localizing value of epileptic nystagmus seems limited in previous reports, the fast phase of epileptic nystagmus was almost always directed away from the epileptic focus that mostly arose from the posterior part of the cerebral hemisphere

    Highly sensitive colorimetric detection of allergies based on an immunoassay using peroxidase-mimicking nanozymes

    Get PDF
    Nanomaterials that exhibit enzyme-like characteristics, which are called nanozymes, have recently attracted significant attention due to their potential to overcome the intrinsic limitations of natural enzymes, such as low stability and relatively high cost for preparation and purification. In this study, we report a highly efficient colorimetric allergy detection system based on an immunoassay utilizing the peroxidase- mimicking activity of hierarchically structured platinum nanoparticles (H-Pt NPs). The H-Pt NPs had a diameter of 30 nm, and were synthesized by a seed-mediated growth method, which led to a significant amount of peroxidase-like activity. This activity mainly occurs because of the high catalytic power of the Pt element, and the fact that the H-Pt NPs have a large surface area available for catalytic events. The H-Pt NPs were conjugated to an antibody for the detection of immunoglobulin E (IgE) in the analytes; IgE is a representative marker for the diagnosis of allergies. They were then successfully integrated into a conventionally used allergy diagnostic test, the ImmunoCAP diagnostic test, as a replacement for natural signaling enzymes. Using this strategy, total and specific IgE levels were detected within 5 min at room temperature, with high specificity and sensitivity. The practical utility of the immunoassay was also successfully verified by correctly determining the levels of both total and specific IgE in real human serum samples with high precision and reproducibility. The present H-Pt NP-based immunoassay system would serve as a platform for rapid, robust, and convenient analysis of IgE, and can be extended to the construction of diagnostic systems for a variety of clinically important target molecules.11Ysciescopu

    Associations between mandibular torus and types of temporomandibular disorders, and the clinical usefulness of temporary splint for checking bruxism

    Get PDF
    Abstract Background Occlusal stress from oral parafunctional habits is one of the causes of temporomandibular disorders (TMD) and mandibular torus (MT). Although some studies have investigated the correlation between TMD and MT, understanding of the relationships between types of TMD and MT is insufficient. Therefore, we conducted this study to investigate the associations between presence of MT and TMD types. Methods This study included 77 patients diagnosed with TMD who first visited our clinic for TMD between March 2019 and July 2020. Among them, 30 (38.9%) had MT, and 54 (70.1%) had oral parafunction. Parafunctional activity during sleep was confirmed using a temporary splint for checking bruxism (TSCB). Results The relationship between prevalence of MT and oral parafunction in TMD patients was not statistically significant (P = 0.131), but the odds ratio was relatively high at 2.267. An analysis of TMD type revealed that Type I, which is classified as myalgia of the masticatory muscles, and MT had a significant association (P = 0.011). We fabricated a TSCB for 27 patients to wear during sleep and confirmed that 23 (85.2%) had nocturnal bruxism. The TSCB results and presence of MT showed a significant relationship (P = 0.047). Conclusion Through the results of this study, clinicians may consider the hyperactivity of masticatory muscles in the presence of MT when treating TMD patients. In addition, TSCB has a great diagnostic value as it can be easily manufactured and be useful for discovering pre-existing oral parafunctions that patients are not aware of

    Rotational Resistance of Surface-Treated Mini-implants

    Get PDF
    Objective: To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. Materials and Methods: A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were tested. Two types of implants were used: some had SLA surface treatment and some had machined surfaces without coating. After 3 weeks of healing, rotational moments of 150 g were applied. The success rates, maximum torque values, angular momentum, and total energy absorbed by the bone were compared. All values were subjected to mixed-model analysis to evaluate the influence of surface treatment, rotational force direction, and site of implantation. Results: The maximum insertion torque and angular momentum of SLA implants were significantly lower than those of machined implants (P = .034, P = .039). The SLA implants had a significantly higher value for total removal energy than the machined implants (P = .046). However, there were no significant differences in total insertion energy, maximum removal torque, and removal angular momentum between the 2 groups. There was no significant difference between clockwise and counterclockwise rotation in all measurements. Conclusion: SLA mini-implants showed relatively lower insertion torque value and angular momentum and higher total energy during removal than the machined implants, suggesting osseointegration of the SLA mini-implant after insertion

    Epstein-Barr Virus-Associated Lymphoepithelioma-Like Gastric Carcinoma Presenting as a Submucosal Mass: CT Findings with Pathologic Correlation

    Get PDF
    A lymphoepithelioma-like carcinoma, characterized by a carcinoma with heavy lymphocyte infiltration, is one of the histological patterns observed in patients with Epstein-Barr virus (EBV)-associated gastric carcinoma. Less than half of invasive carcinomas with lymphoepithelioma-like histology can grow to make a submucosal mass. These tumors generally have a better prognosis than conventional adenocarcinomas. We report a case of an EBV-associated lymphoepithelioma-like gastric carcinoma that presented as a submucosal mass on multi-detector (MD) CT and correlate them with the pathology

    Gallbladder Pseudodiverticulosis Mimicking a Multiseptate Gallbladder with Stones

    Get PDF
    Gallbladder diverticula have the appearance of hernia-like protrusions of the gallbladder wall. This disorder may not be diagnosed until surgically resected because it has no clinical significance unless there are associated diseases. Gallbladder pseudodiverticula have an acquired cause, multiple fundal lesions, an association with gallstones, internal saccular lesions without external hernia-like protrusions, and little to no smooth muscle in the gallbladder wall. We report a unique anomaly of multiple pseudodiverticula presenting with calculous cholecystitis, which was pathologically different from true diverticula and had a unique shape similar to a bunch of grapes and a septation infilling pattern on endoscopic retrograde cholangiography

    How does the multidimensional frailty score compare with grip strength for predicting outcomes after hip fracture surgery in older patients? A retrospective cohort study

    Get PDF
    Background Frailty and low handgrip strength (HGS) are associated with adverse outcomes after hip fracture (HF) surgery. We aimed to compare the predictive role of frailty and HGS for adverse outcome in HF patients. Methods We included older patients (age ≥ 65 years) who underwent HF surgery to compare the predictive role of HGS and hip-multidimensional frailty score (Hip-MFS) for postoperative complications and mortality. The Hip-MFS was calculated based on comprehensive geriatric assessment (CGA), and HGS was measured with a hand dynamometer. The primary outcome was a composite of postoperative complications (e.g., pneumonia, urinary tract infection, delirium, acute pulmonary thromboembolism, and unplanned intensive care unit admission). The secondary outcomes were 6-month mortality and mortality at the end of follow-up. Results The median observation time was 620.5 days (interquartile range: 367.0–784.8 days). Among the 242 patients (mean age: 81.5 ± 6.7 years, 73.1% women), 106 (43.8%) experienced postoperative complications. The 6-month mortality and mortality at the end of follow-up were 7.4% (n = 18) and 20.7% (n = 50), respectively. The Hip-MFS (odds ratio [OR], 1.250; 95% confidence interval [CI], 1.092–1.432) and HGS (OR, 1.147; 95% CI, 1.082–1.215) could predict postoperative complications. The Hip-MFS could predict both 6-month mortality (hazard ratio [HR], 1.403; 95% CI, 1.027–1.917) and mortality at the end of follow-up (HR, 1.493; 95% CI, 1.249–1.769) after adjustment, while HGS was only associated with mortality at the end of follow-up (HR, 1.080; 95% CI, 1.024–1.139). For mortality at the end of follow-up, predictive models with the Hip-MFS were superior to those with HGS in the time-dependent receiver-operating curve analysis after adjustment (p = 0.017). Furthermore, the addition of Hip-MFS or HGS to the American Society of Anesthesiologists (ASA) classification improved its prognostic ability. Conclusions Both the Hip-MFS and HGS could predict postoperative complications and improve prognostic utility when combined with the ASA classification. The Hip-MFS was a stronger predictor of mortality than HGS after HF surgery. HGS could be a useful pre-screening tool to identify patients at a high risk of postoperative complications and those who may benefit from further CGA.This research was supported by the grants from the Seoul National University Bundang Hospital (SNUBH) Research Fund [grant number 14–2017-023]. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript
    corecore