18 research outputs found

    H-terminated polycrystalline boron doped diamond electrode for geochemical sensing into underground components of nuclear repositories

    No full text
    Nuclear waste repositories are being installed in deep excavated rock formations in some places in Europe to isolate and store radioactive waste. In France, Callovo-Oxfordian formation (COx) is potential candidate for nuclear waste repository. It is thus necessary to measure in situ the state of a structure's health during its entire life. The monitoring of the near-field rock and the knowledge of the geochemical transformations can be carried out by a set of sensors for a sustainable management of long-term safety, reversibility and retrievability. Among the chemical parameters, the most significant are pH, conductivity and redox potential. Wide band gap semiconductors are favored materials for chemical sensing because of their high stability to many chemical agents. Among the wide band gap materials, Chemical Vapor Deposition (CVD) boron doped diamond (BDD) benefits from a large band gap (5.45 eV), which gives rise to a wide electrochemical potential window (~3 V/Saturated Calomel Electrode(SCE)) (Angus et al. 1999). It is moreover described as a radiation, corrosion and bio-corrosion resistant. These remarkable properties, in addition to a low double layer capacity and a low residual current, make BDD a promising material for geochemical sensor elaboration. This work aimed to investigate BDD- based electrodes coated with p-type polycrystalline BDD- hydrogen-terminated surfaces (1 cm2) for pH and/or redox measurements into the underground components of nuclear repositories. The boron-doped p-type channel was grown in a microwave plasma reactor (BJS 150) (Silva et al. 2009). The boron-doped channel was hydrogen terminated by a hydrogen plasma treatment in the CVD reactor, resulting in full saturation of the surface carbon bonds with hydrogen atoms. Figure 1 shows the Scanning Electron Microscopy (SEM) of the polycrystalline BDD coating with a Bore/Carbon ratio of 500 ppm and its Raman spectrum. SEM micrograph illustrates the typical columnar growth of the polycrystalline CVD diamond. A homogeneous surface was observed concerning the crystallite size which average was 1.5 microns. On the Raman spectrum of a single crystal diamond intrinsic film (undoped), the diamond peak is usually observed at 1332 cm-1. In Figure 1, the intense peak at 1327 cm-1 corresponding to diamond is shifted due to the "Fano" effect according to doping, which is observed through a broad peak at 910 cm-1. Its intensity shows that the investigated sample was highly doped. Gheeraert et al. (1993) suggested that the peaks at 500 and 1230 cm-1 appears when the boron concentration reaches the critical value of 3×1020 at.cm-3 corresponding to a metallic conductivity. The lack of peak around 1350 cm-1 and 1570 cm-1, which corresponds respectively to D and G graphite peak of impurity phases of non-diamond carbon (sp2), attests to the crystalline quality of the deposit. The slight width at half maximum of the characteristic peak of diamond compared to that of natural diamond reflects the degree of organization and structural perfection of this phase indicating that the coating was of high quality. Electrodes made in this way have been used for 8 month without any surface treatments or conditioning. The electrochemical behavior of Hydrogen-terminated BDD was studied by cyclic voltammetry. Electrodes showed a wide potential range of about 2 V/SCE. They also showed and a rapid reversible charge transfer in the presence of redox probes such FeCN63-/4- and Ru(NH)63+/2+. Performances, reliability and robustness for pH or redox monitoring were examined by potentiometric measurements at 25°C under anaerobic conditions (oxygen-free atmosphere, 100 % nitrogen) in a glove box. Investigation has been limited in pH, ranging from 5.5 to 13.5, close to those encountered in the environment of the nuclear repositories. The feasibility of measuring pH with BDD electrodes was first tested in NH4Cl/NH3-NaCl (0.1mol L-1) buffer solutions, leading to electrode calibration over the widest range of pH, from around neutral to basic pH. Experiments were also conducted in NaHCO3/Na2CO3 buffer samples, similar to conditions prevailing in the COx formation. For redox measurements, [Fe3+]/[Fe2+] ratios were analysed at different pH and/or ionic strengths (supporting electrolytes concentration ranged from 0.05 to 1 mol.L-1). The same measurements were also done using a 10-mm disk platinum electrode with a surface of 78.54 mm². No pH sensitivity was observed, thus the energy level of the state was not moved. However, for redox measurements the potential acquired by Hydrogen-terminated BDD and Platinum electrode converged to a value of the same order of magnitude, independently of the sample. This fact demonstrates that, under the same experimental conditions, the redox couples fixe identically the potential of the electrodes. Investigations with reference to ionic strength in thermodynamically equilibrated Fe(III)/Fe(II) samples were highly interesting. Independently of the electrode, the voltage measurement was not or little affected, whereas both the solution conductivity as well as the speciation were affected, due to the increase in salinity. This means that the term [Fe3+]/[Fe2+] is practically unaffected. This implies that assuming the ratio of the activity coefficients, γFe3+/ γFe2+ as equal to 1 has a minor effect on the measured redox potential. H-terminated BDD electrode appears well suited for redox monitoring. Work is in progress to demonstrate the robustness of the H-terminated BDD electrode for redox monitoring into COx over a long period

    The use of a combined bipedicled axial perforator based fasciocutaneous flap for the treatment of a traumatic diabetic foot wound: a case report

    Get PDF
    The axial and perforator vascularised fasciocutaneous flaps are reliable and effective treatment methods for covering lower limb post-traumatic, septic, Charcot, and diabetic foot wounds. The authors describe the unique utilisation of a hybrid flap as an axial-perforator flap combination for the treatment of a traumatic diabetic foot wound

    Influence of temperature and surfactants on the solubilization of hexachlorobutadiene and hexachloroethane

    Get PDF
    The solubilization of hexachlorobutadiene (HCBD) and hexachloroethane (HCA) in water as a function of temperature and in the presence of surfactants was investigated in order to predict their fate in groundwater and to increase their recovery. HCBD and HCA solubility data were experimentally determined at five temperatures in the range from (285.15 to 318.15) K. Thermodynamic parameters for dissolution (ΔsolG°, ΔsolH°, and ΔsolS°) have been calculated in order to propose a physical explanation of the minimum solubility observed between 293.15 and 298.15 K for both compounds. The solubilization process appeared to be influenced by the network of water molecules rather than by physical and chemical properties of HCBD or HCA, due to an opposite effect of temperature onto Brownian motion, which increases with temperature, and hydrogen-bond network, which collapses with temperature. Concerning the influence of surfactants, determination of the micelle–water partition coefficients (Kmw) and the molar solubilization ratio (MSR) has shown that the solubilization per micelle was more important for nonionic surfactants Triton X-100 and Tween 80 than for anionic SDBS. Also, the increase of solubility was 1 order of magnitude higher for liquid HCBD than for crystalline HCA irrespective of surfactant

    Anatomical repair of distal biceps brachii tendon rupture through a limited anterior approach

    No full text
    To avoid the extended anterior or the two-incision approach to the radius, we present a limited anterior approach for anatomical reattachment at the radial tuberosity of the distal biceps brachii tendon complete rupture using suture anchors. Our clinical experience in nine patients showed that secure fixation obtained with the suture anchors, limited surgical approach and anatomical reconstruction allow for early mobilization and rapid return of function, and provide excellent long-term results with acceptable complications. We suggest using the limited anterior approach in patients with early (less than 6 weeks) distal biceps brachii tendon rupture

    Complications of open carpal tunnel surgery: avoiding the pitfalls

    No full text
    We present a series of 31 patients treated for complications following open carpal tunnel syndrome surgery over a time period of 10 years. The most frequent complications encountered were major nerve lacerations at the wrist and thenar followed by persistent and recurrent symptoms, neuroma formation and wound infection. All patients had primary treatment by a different approach, by different spectrum of training surgeons; in only one patient, the initial operating surgeon was an orthopedic surgeon in hand fellowship training. In ten patients, the typical approach to the carpal tunnel has been used at the initial operation; an excessive ulnar-directed incision and a long proximal- and radial-directed incision have been observed in ten and eight patients, respectively; a mini-open incision and an incision that crossed the wrist perpendicular to the flexion creases have been observed in one and two patients, each. Most complications of open carpal tunnel surgery can be prevented by specialized training in hand surgery of the operative surgeon and proper operative technique, including a properly placed incision and exposure under magnification and direct vision
    corecore