425 research outputs found
Interplay between multiple scattering, emission, and absorption of light in the phosphor of a white light-emitting diode
We study light transport in phosphor plates of white light-emitting diodes
(LEDs). We measure the broadband diffuse transmission through phosphor plates
of varying YAG:Ce density. We distinguish the spectral ranges where
absorption, scattering, and re-emission dominate. Using diffusion theory, we
derive the transport and absorption mean free paths from first principles. We
find that both transport and absorption mean free paths are on the order of the
plate thickness. This means that phosphors in commercial LEDs operate well
within an intriguing albedo range around 0.7. We discuss how salient parameters
that can be derived from first principles control the optical properties of a
white LED.Comment: 14 pages, 9 figure
Gonadotrophin-releasing hormone receptors (version 2019.4) in the IUPHAR/BPS Guide to Pharmacology Database
GnRH1 and GnRH2 receptors (provisonal nomenclature [35], also called Type I and Type II GnRH receptor, respectively [78]) have been cloned from numerous species, most of which express two or three types of GnRH receptor [78, 77, 107]. GnRH I (p-Glu-His-Trp-Ser-Tyr-Gly-Leu-Arg-Pro-Gly-NH2) is a hypothalamic decapeptide also known as luteinizing hormone-releasing hormone, gonadoliberin, luliberin, gonadorelin or simply as GnRH. It is a member of a family of similar peptides found in many species [78, 77, 107] including GnRH II (pGlu-His-Trp-Ser-His-Gly-Trp-Tyr-Pro-Gly-NH2 (which is also known as chicken GnRH-II). Receptors for three forms of GnRH exist in some species but only GnRH I and GnRH II and their cognate receptors have been found in mammals [78, 77, 107]. GnRH1 receptors are expressed by pituitary gonadotrophs, where they mediate the effects of GnRH on gonadotropin hormone synthesis and secretion that underpin central control of mammalian reproduction. GnRH analogues are used in assisted reproduction and to treat steroid hormone-dependent conditions [53]. Notably, agonists cause desensitization of GnRH-stimulated gonadotropin secretion and the consequent reduction in circulating sex steroids is exploited to treat hormone-dependent cancers of the breast, ovary and prostate [53]. GnRH1 receptors are selectively activated by GnRH I and all lack the COOH-terminal tails found in other GPCRs. GnRH2 receptors do have COOH-terminal tails and (where tested) are selective for GnRH II over GnRH I. GnRH2 receptors are expressed by some primates but not by humans [81]. Phylogenetic classifications divide GnRH receptors into three [78] or five groups [122] and highlight examples of gene loss through evolution, with humans retaining only one ancient gene
Gonadotrophin-releasing hormone receptors in GtoPdb v.2021.3
GnRH1 and GnRH2 receptors (provisonal nomenclature [39], also called Type I and Type II GnRH receptor, respectively [85]) have been cloned from numerous species, most of which express two or three types of GnRH receptor [85, 84, 114]. GnRH I (p-Glu-His-Trp-Ser-Tyr-Gly-Leu-Arg-Pro-Gly-NH2) is a hypothalamic decapeptide also known as luteinizing hormone-releasing hormone, gonadoliberin, luliberin, gonadorelin or simply as GnRH. It is a member of a family of similar peptides found in many species [85, 84, 114] including GnRH II (pGlu-His-Trp-Ser-His-Gly-Trp-Tyr-Pro-Gly-NH2 (which is also known as chicken GnRH-II). Receptors for three forms of GnRH exist in some species but only GnRH I and GnRH II and their cognate receptors have been found in mammals [85, 84, 114]. GnRH1 receptors are expressed by pituitary gonadotrophs, where they mediate the effects of GnRH on gonadotropin hormone synthesis and secretion that underpin central control of mammalian reproduction. GnRH analogues are used in assisted reproduction and to treat steroid hormone-dependent conditions [58]. Notably, agonists cause desensitization of GnRH-stimulated gonadotropin secretion and the consequent reduction in circulating sex steroids is exploited to treat hormone-dependent cancers of the breast, ovary and prostate [58]. GnRH1 receptors are selectively activated by GnRH I and all lack the COOH-terminal tails found in other GPCRs. GnRH2 receptors do have COOH-terminal tails and (where tested) are selective for GnRH II over GnRH I. GnRH2 receptors are expressed by some primates but not by humans [88]. Phylogenetic classifications divide GnRH receptors into three [85] or five groups [129] and highlight examples of gene loss through evolution, with humans retaining only one ancient gene. The structure of the GnRH1 receptor in complex with elagolix has been elucidated [132]
The association between birth weight and plasma fibrinogen is abolished after the elimination of genetic influences
Low birth weight is associated with an increased risk of atherothrombosis, which may be related in part to the association between low birth weight and high plasma fibrinogen. The association between birth weight and fibrinogen may be explained by intrauterine, socio-economic or genetic factors. We examined birth weight and fibrinogen in 52 dizygotic and 56 adolescent monozygotic (genetically identical) twin pairs. The dizygotic but not the monozygotic twins with the lowest birth weight from each pair had a fibrinogen level that was higher compared with their co-twins with the highest birth weight [dizygotic twins: 2.62±0.46 g
Detection of osteomyelitis in the diabetic foot by imaging techniques. A systematic review and meta-analysis comparing mri, white blood cell scintigraphy, and FDG-PET
OBJECTIVE Diagnosing bone infection in the diabetic foot is challenging and often requires several diagnostic procedures, including advanced imaging. We compared the diagnostic performances of MRI, radiolabeled white blood cell (WBC) scintigraphy (either with 99mTc-hexamethylpropyleneamineoxime [HMPAO] or 111In-oxine), and [18F]fluorodeoxyglucose positron emission tomography (18F-FDG-PET)/ computed tomography. RESEARCH DESIGN AND METHODS We searchedMedline andEmbase as of August 2016 for studies of diagnostic tests on patients known or suspected to have diabetes and a foot infection. We performed a systematic review using criteria recommended by the Cochrane Review of a database that included prospective and retrospective diagnostic studies performed on patients with diabetes in whom there was a clinical suspicion of osteomyelitis of the foot. The preferred reference standard was bone biopsy and subsequent pathological (or microbiological) examination. RESULTS Our review found 6,649 articles; 3,894 in Medline and 2,755 in Embase. A total of 27 full articles and 2 posters was selected for inclusion in the analysis. The performance characteristics for the 18F-FDG-PET were: sensitivity, 89%; specificity, 92%; diagnostic odds ratio (DOR), 95; positive likelihood ratio (LR), 11; and negative LR, 0.11. For WBC scan with 111In-oxine, the values were: sensitivity, 92%; specificity, 75%; DOR, 34; positive LR, 3.6; and negative LR, 0.1. For WBC scan with 99mTc-HMPAO, the values were: sensitivity, 91%; specificity, 92%; DOR, 118; positive LR, 12; and negative LR, 0.1. Finally, forMRI, the valueswere: sensitivity, 93%; specificity, 75%; DOR, 37; positive LR, 3.66, and negative LR, 0.10. CONCLUSIONS The various modalities have similar sensitivity, but 18F-FDG-PET and 99mTc-HMPAO-labeled WBC scintigraphy offer the highest specificity. Larger prospective studies with a direct comparison among the different imaging techniques are required
Decision for reconstructive interventions of the upper limb in individuals with tetraplegia: the effect of treatment characteristics
Objective: To determine the effect of treatment characteristics on the\ud
decision for reconstructive interventions for the upper extremities (UE) in\ud
subjects with tetraplegia. - \ud
Setting: Seven specialized spinal cord injury centres in the Netherlands. - \ud
Method: Treatment characteristics for UE reconstructive interventions were\ud
determined. Conjoint analysis (CA) was used to determine the contribution\ud
and the relative importance of the treatment characteristics on the decision\ud
for therapy. Therefore, a number of different treatment scenarios using these\ud
characteristics were established. Different pairs of scenarios were presented\ud
to subjects who were asked to choose the preferred scenario of each set. - \ud
Results: forty nine subjects with tetraplegia with a stable C5, C6 or C7\ud
lesion were selected. All treatment characteristics significantly influenced\ud
the choice for treatment. Relative importance of treatment characteristics\ud
were: intervention type (surgery or surgery with FES implant) 13%, number\ud
of operations 15%, in patient rehabilitation period 22%, ambulant\ud
rehabilitation period 9%, complication rate 15%, improvement of elbow\ud
function 10%, improvement of hand function 15%. In deciding for therapy\ud
40% of the subjects focused on one characteristic. - \ud
Conclusion: CA is applicable in Spinal Cord Injury medicine to study the\ud
effect of health outcomes and non-health outcomes on the decision for\ud
treatment. Non-health outcomes which relate to the intensity of treatment\ud
are equally important or even more important than functional outcome in the\ud
decision for reconstructive UE surgery in subjects with tetraplegia
User needs elicitation via analytic hierarchy process (AHP). A case study on a Computed Tomography (CT) scanner
Background:
The rigorous elicitation of user needs is a crucial step for both medical device design and purchasing. However, user needs elicitation is often based on qualitative methods whose findings can be difficult to integrate into medical decision-making. This paper describes the application of AHP to elicit user needs for a new CT scanner for use in a public hospital.
Methods:
AHP was used to design a hierarchy of 12 needs for a new CT scanner, grouped into 4 homogenous categories, and to prepare a paper questionnaire to investigate the relative priorities of these. The questionnaire was completed by 5 senior clinicians working in a variety of clinical specialisations and departments in the same Italian public hospital.
Results:
Although safety and performance were considered the most important issues, user needs changed according to clinical scenario. For elective surgery, the five most important needs were: spatial resolution, processing software, radiation dose, patient monitoring, and contrast medium. For emergency, the top five most important needs were: patient monitoring, radiation dose, contrast medium control, speed run, spatial resolution.
Conclusions:
AHP effectively supported user need elicitation, helping to develop an analytic and intelligible framework of decision-making. User needs varied according to working scenario (elective versus emergency medicine) more than clinical specialization. This method should be considered by practitioners involved in decisions about new medical technology, whether that be during device design or before deciding whether to allocate budgets for new medical devices according to clinical functions or according to hospital department
- …