13 research outputs found

    Is short-term-variation of fetal-heart-rate a better predictor of fetal acidaemia in labour? A feasibility study

    Get PDF
    Background Continuous intrapartum fetal monitoring is challenging and its clinical benefits are debated. The project evaluated whether short-term-variation (STV) and other computerised fetal heart rate (FHR) parameters (baseline FHR, long-term-variation, accelerations and decelerations) predicted acidaemia at birth. The aims of the study were to assess the changes in FHR pattern during labour and determine the feasibility of undertaking a definitive trial by reporting the practicalities of using the monitoring device, participant recruitment, data collection and staff training. Methods 200 high-risk women carrying a term singleton, non-anomalous fetus, requiring continuous FHR monitoring in labour were consented to participate from the Jessop Wing maternity unit, Sheffield, UK. The trans-abdominal fetal ECG monitor was placed as per clinical protocol. During the monitoring session, clinicians were blinded to the computerised FHR parameters. We analysed the last hour of the FHR and its ability to predict umbilical arterial blood pH <7.20 using receiver operator characteristics (ROC) curves. Results Of 200 women, 137 cases were excluded as either the monitor did not work from the onset of labour (n = 30), clinical staff did not return or used the monitor on another patient (n = 37), umbilical cord blood not obtained (n = 25), FHR data not recorded within an hour of birth (n = 34) and other reasons (n = 11). In 63 cases included in the final analysis, the computer-derived FHR parameters did not show significant correlation with umbilical artery cord pH <7.20. Labour was associated with a significant increase in short and long term variation of FHR and number of deceleration (P<0.001). However, baseline FHR decreased significantly before delivery (P<0.001). Conclusions The project encountered a number of challenges, with learning points crucial to informing the design of a large study to evaluate the potential place of intrapartum computerised FHR parameters, using abdominal fetal ECG monitor before its clinical utility and more widespread adoption can be ascertained

    Induction of labour versus expectant management in women with preterm prelabour rupture of membranes between 34 and 37 weeks (the PPROMEXIL-trial)

    Get PDF
    Contains fulltext : 53155.pdf ( ) (Open Access)BACKGROUND: Preterm prelabour rupture of the membranes (PPROM) is an important clinical problem and a dilemma for the gynaecologist. On the one hand, awaiting spontaneous labour increases the probability of infectious disease for both mother and child, whereas on the other hand induction of labour leads to preterm birth with an increase in neonatal morbidity (e.g., respiratory distress syndrome (RDS)) and a possible rise in the number of instrumental deliveries. METHODS/DESIGN: We aim to determine the effectiveness and cost-effectiveness of immediate delivery after PPROM in near term gestation compared to expectant management. Pregnant women with preterm prelabour rupture of the membranes at a gestational age from 34+0 weeks until 37+0 weeks will be included in a multicentre prospective randomised controlled trial. We will compare early delivery with expectant monitoring.The primary outcome of this study is neonatal sepsis. Secondary outcome measures are maternal morbidity (chorioamnionitis, puerperal sepsis) and neonatal disease, instrumental delivery rate, maternal quality of life, maternal preferences and costs. We anticipate that a reduction of neonatal infection from 7.5% to 2.5% after induction will outweigh an increase in RDS and additional costs due to admission of the child due to prematurity. Under these assumptions, we aim to randomly allocate 520 women to two groups of 260 women each. Analysis will be by intention to treat. Additionally a cost-effectiveness analysis will be performed to evaluate if the cost related to early delivery will outweigh those of expectant management. Long term outcomes will be evaluated using modelling. DISCUSSION: This trial will provide evidence as to whether induction of labour after preterm prelabour rupture of membranes is an effective and cost-effective strategy to reduce the risk of neonatal sepsis. CONTROLLED CLINICAL TRIAL REGISTER: ISRCTN29313500

    Neural reflex pathways in intestinal inflammation: hypotheses to viable therapy

    No full text
    Studies in neuroscience and immunology have clarified much of the anatomical and cellular basis for bidirectional interactions between the nervous and immune systems. As with other organs, intestinal immune responses and the development of immunity seems to be modulated by neural reflexes. Sympathetic immune modulation and reflexes are well described, and in the past decade the parasympathetic efferent vagus nerve has been added to this immune-regulation network. This system, designated 'the inflammatory reflex', comprises an afferent arm that senses inflammation and an efferent arm that inhibits innate immune responses. Intervention in this system as an innovative principle is currently being tested in pioneering trials of vagus nerve stimulation using implantable devices to treat IBD. Patients benefit from this treatment, but some of the working mechanisms remain to be established, for instance, treatment is effective despite the vagus nerve not always directly innervating the inflamed tissue. In this Review, we will focus on the direct neuronal regulatory mechanisms of immunity in the intestine, taking into account current advances regarding the innervation of the spleen and lymphoid organs, with a focus on the potential for treatment in IBD and other gastrointestinal pathologies
    corecore