1,006 research outputs found

    Ultraviolet and soft X--ray photon--photon elastic scattering in an electron gas

    Full text link
    We have considered the processes which lead to elastic scattering between two far ultraviolet or X--ray photons while they propagate inside a solid, modeled as a simple electron gas. The new ingredient, with respect to the standard theory of photon--photon scattering in vacuum, is the presence of low--energy, nonrelativistic electron--hole excitations. Owing to the existence of two--photon vertices, the scattering processes in the metal are predominantly of second order, as opposed to fourth order for the vacuum case. The main processes in second order are dominated by exchange of virtual plasmons between the two photons. For two photons of similar energy ℏΩ\hbar \Omega, this gives rise to a cross section rising like Ω2\Omega^2 up to maximum of around 10−3210^{-32}~cm2^2, and then decreasing like Ω−6\Omega^{-6}. The maximal cross section is found for the photon wavevector k∌kFk \sim k_{F}, the Fermi surface size, which typically means a photon energy ℏΩ\hbar \Omega in the keV range. Possible experiments aimed at checking the existence of these rare but seemingly measurable elastic photon--photon scattering processes are discussed, using in particular intense synchrotron sources.Comment: 33 pages, TeX, Version 3.1, S.I.S.S.A. preprint 35/93/C

    Uncertainty Quantification in Bayesian Reduced-Rank Sparse Regressions

    Full text link
    Reduced-rank regression recognises the possibility of a rank-deficient matrix of coefficients, which is particularly useful when the data is high-dimensional. We propose a novel Bayesian model for estimating the rank of the rank of the coefficient matrix, which obviates the need of post-processing steps, and allows for uncertainty quantification. Our method employs a mixture prior on the regression coefficient matrix along with a global-local shrinkage prior on its low-rank decomposition. Then, we rely on the Signal Adaptive Variable Selector to perform sparsification, and define two novel tools, the Posterior Inclusion Probability uncertainty index and the Relevance Index. The validity of the method is assessed in a simulation study, then its advantages and usefulness are shown in real-data applications on the chemical composition of tobacco and on the photometry of galaxies

    Towards a direct measurement of vacuum magnetic birefringence: PVLAS achievements

    Full text link
    Nonlinear effects in vacuum have been predicted but never observed yet directly. The PVLAS collaboration has long been working on an apparatus aimed at detecting such effects by measuring vacuum magnetic birefringence. Unfortunately the sensitivity has been affected by unaccounted noise and systematics since the beginning. A new small prototype ellipsometer has been designed and characterized at the Department of Physics of the University of Ferrara, Italy entirely mounted on a single seismically isolated optical bench. With a finesse F = 414000 and a cavity length L = 0.5 m we have reached the predicted sensitivity of psi = 2x10^-8 1/sqrt(Hz) given the laser power at the output of the ellipsomenter of P = 24 mW. This record result demonstrates the feasibility of reaching such sensitivities and opens the way to designing a dedicated apparatus for a first detection of vacuum magnetic birefringence

    Evidence-based practice among Italian osteopaths: a national cross-sectional survey.

    Full text link
    BackgroundWhile evidence-based practice (EBP) is widely accepted across healthcare professions, research investigating its implementation in manual therapy professions such as osteopathy is limited. The primary aim of this study was to investigate Italian osteopaths' attitudes, skills, and use of EBP. A secondary purpose was to understand the obstacles and enablers to EBP adoption in the Italian osteopathic context.MethodsA cross-sectional national survey was conducted (April to June 2020) among a sample of Italian osteopaths. Eligible participants were invited to complete the Italian-translated Evidence-Based practice Attitude and Utilization Survey (EBASE) anonymously online using various recruitment strategies, including email and social media campaigns. In addition to the three EBASE sub-scores (attitudes, skills and use), the demographic characteristics of the sample were considered.ResultsA total of 473 osteopaths responded to the survey. The sample appeared to represent the Italian osteopathic profession. The majority of participants had a favorable attitude toward EBP. Eighty-eight percent of respondents agreed that EBP was necessary for osteopathy practice and that scientific literature and research findings were beneficial to their clinical scenario (95%). Perceived skill levels in EBP were rated as moderate, with the lowest scores for items relating to clinical research and systematic review conduct. Apart from reading/reviewing scientific literature and using online search engines to locate relevant research papers, participant engagement in all other EBP-related activities was generally low. Clinical practice was perceived to be based on a very small proportion of clinical research evidence. The primary obstacles to EBP implementation were a dearth of clinical evidence in osteopathy, and poor skills in applying research findings. The primary enablers of EBP adoption were access to full-text articles, internet connectivity at work, and access to online databases.ConclusionsItalian osteopaths were largely supportive of evidence-based practice but lacked basic skills in EBP and rarely engaged in EBP activities. The updating of osteopathic training curriculum and professional formal regulation in Italy could provide a suitable framework to improve EBP skills and use

    Limits on the violation of g-universality with a Galileo-type experiment

    Get PDF
    Abstract We present new results for a Galilean experiment using two masses of copper and tungsten in simultaneous free fall. The experiment searches for a possible difference in the free-fall acceleration Δ g and it is sensitive to any composition-dependent interaction between the test masses and the earth, whose range exceeds 10 km. The results show no evidence for any composition-dependent gravity-like interaction within Δg ÎŒ Gal

    Probing For New Physics and Detecting non linear vacuum QED effects using gravitational wave interferometer antennas

    Get PDF
    Low energy non linear QED effects in vacuum have been predicted since 1936 and have been subject of research for many decades. Two main schemes have been proposed for such a 'first' detection: measurements of ellipticity acquired by a linearly polarized beam of light passing through a magnetic field and direct light-light scattering. The study of the propagation of light through an external field can also be used to probe for new physics such as the existence of axion-like particles and millicharged particles. Their existence in nature would cause the index of refraction of vacuum to be different from unity in the presence of an external field and dependent of the polarization direction of the light propagating. The major achievement of reaching the project sensitivities in gravitational wave interferometers such as LIGO an VIRGO has opened the possibility of using such instruments for the detection of QED corrections in electrodynamics and for probing new physics at very low energies. In this paper we discuss the difference between direct birefringence measurements and index of refraction measurements. We propose an almost parasitic implementation of an external magnetic field along the arms of the VIRGO interferometer and discuss the advantage of this choice in comparison to a previously proposed configuration based on shorter prototype interferometers which we believe is inadequate. Considering the design sensitivity in the strain, for the near future VIRGO+ interferometer, of h<2⋅10−231Hzh<2\cdot10^{-23} \frac{1}{\sqrt{\rm Hz}} in the range 40 Hz −400- 400 Hz leads to a variable dipole magnet configuration at a frequency above 20 Hz such that B2D≄13000B^{2}D \ge 13000 T2^{2}m/Hz\sqrt{\rm Hz} for a `first' vacuum non linear QED detection

    Precise mirror alignment and basic performance of the RICH detector of the NA62 experiment at CERN

    Get PDF
    The Ring Imaging Cherenkov detector is crucial for the identification of charged particles in the NA62 experiment at the CERN SPS. The detector commissioning was completed in 2016 by the precise alignment of mirrors using reconstructed tracks. The alignment procedure and measurement of the basic performance are described. Ring radius resolution, ring centre resolution, single hit resolution and mean number of hits per ring are evaluated for positron tracks. The contribution of the residual mirror misalignment to the performance is calculated.Comment: 13 pages, 10 figure

    The Casimir force and the quantum theory of lossy optical cavities

    Get PDF
    We present a new derivation of the Casimir force between two parallel plane mirrors at zero temperature. The two mirrors and the cavity they enclose are treated as quantum optical networks. They are in general lossy and characterized by frequency dependent reflection amplitudes. The additional fluctuations accompanying losses are deduced from expressions of the optical theorem. A general proof is given for the theorem relating the spectral density inside the cavity to the reflection amplitudes seen by the inner fields. This density determines the vacuum radiation pressure and, therefore, the Casimir force. The force is obtained as an integral over the real frequencies, including the contribution of evanescent waves besides that of ordinary waves, and, then, as an integral over imaginary frequencies. The demonstration relies only on general properties obeyed by real mirrors which also enforce general constraints for the variation of the Casimir force.Comment: 18 pages, 6 figures, minor amendment

    Light Detection System and Time Resolution of the NA62 RICH

    Get PDF
    A large RICH detector is used in NA62 to suppress the muon contamination in the charged pion sample by a factor of 100 in the momentum range between 15 and 35 GeV/c. Cherenkov light is collected by 1952 photomultipliers placed at the upstream end. In this paper the characterization of the photomultipliers and the dedicated Frontend and Data Acquisition electronics are described, the time resolution and the light detection efficiency measurement are presented.Comment: 15 pages, 11 figure
    • 

    corecore