452 research outputs found

    Study of the eta meson production with polarized proton beam

    Full text link
    The pp-> pp eta reaction was investigated at excess energies of 15 MeV and 72 MeV using the azimuthally symmetric WASA detector and a polarized proton beam of the Cooler Synchrotron COSY. The aim of the studies is the determination of partial wave contributions to the production process of the eta meson in nucleon-nucleon collisions. Here we present preliminary results of the extraction of the position of the interaction region with respect to the WASA detector and preliminary results on the degree of polarization of the COSY proton beam used in the experiment.Comment: Invited talk at the Second International Symposium on Mesic Nuclei, Cracow, Poland, September 22-25 201

    Beam profile investigation of the new collimator system for the J-PET detector

    Get PDF
    Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector which will be used for search for discrete symmetries violations in the decays of positronium atoms and for investigations with positronium atoms in life-sciences and medical diagnostics. In this article we present three methods for determination of the beam profile of collimated annihilation gamma quanta. Precise monitoring of this profile is essential for time and energy calibration of the J-PET detector and for the determination of the library of model signals used in the hit-time and hit-position reconstruction. We have we have shown that usage of two lead bricks with dimensions of 5x10x20 cm^3 enables to form a beam of annihilation quanta with Gaussian profile characterized by 1 mm FWHM. Determination of this characteristic is essential for designing and construction the collimator system for the 24-module J-PET prototype. Simulations of the beam profile for different collimator dimensions were performed. This allowed us to choose optimal collimation system in terms of the beam profile parameters, dimensions and weight of the collimator taking into account the design of the 24 module J-PET detector.Comment: 14 pages, 9 figure

    Determination of the map of efficiency of the J-PET detector with the GATE package

    Full text link
    A novel PET detector consisting of strips of polymer scintillators is being developed by the J-PET Collaboration. The map of efficiency and the map of geometrical acceptance of the 2-strip J-PET scanner are presented. Map of efficiency was determined using the Monte Carlo simulation software GATE based on GEANT4. Both maps were compared using method based on the chi2 test.Comment: 14 pages, 9 figures, proceeding from conference Symposium on Positron Emission Tomography: http://koza.if.uj.edu.pl/pet-symposium-2013

    Test of a single module of the J-PET scanner based on plastic scintillators

    Full text link
    Time of Flight Positron Emission Tomography scanner based on plastic scintillators is being developed at the Jagiellonian University by the J-PET collaboration. The main challenge of the conducted research lies in the elaboration of a method allowing application of plastic scintillators for the detection of low energy gamma quanta. In this article we report on tests of a single detection module built out from BC-420 plastic scintillator strip (with dimensions of 5x19x300mm^3) read out at two ends by Hamamatsu R5320 photomultipliers. The measurements were performed using collimated beam of annihilation quanta from the 68Ge isotope and applying the Serial Data Analyzer (Lecroy SDA6000A) which enabled sampling of signals with 50ps intervals. The time resolution of the prototype module was established to be better than 80ps (sigma) for a single level discrimination. The spatial resolution of the determination of the hit position along the strip was determined to be about 0.93cm (sigma) for the annihilation quanta. The fractional energy resolution for the energy E deposited by the annihilation quanta via the Compton scattering amounts to sigma(E)/E = 0.044/sqrt(E[MeV]) and corresponds to the sigma(E)/E of 7.5% at the Compton edge.Comment: 12 pages, 6 figures; Updated with editorial corrections related to publication in NIM

    Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography

    Full text link
    Currently inorganic scintillator detectors are used in all commercial Time of Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration investigates a possibility of construction of a PET scanner from plastic scintillators which would allow for single bed imaging of the whole human body. This paper describes a novel method of hit-position reconstruction based on sampled signals and an example of an application of the method for a single module with a 30 cm long plastic strip, read out on both ends by Hamamatsu R4998 photomultipliers. The sampling scheme to generate a vector with samples of a PET event waveform with respect to four user-defined amplitudes is introduced. The experimental setup provides irradiation of a chosen position in the plastic scintillator strip with an annihilation gamma quanta of energy 511~keV. The statistical test for a multivariate normal (MVN) distribution of measured vectors at a given position is developed, and it is shown that signals sampled at four thresholds in a voltage domain are approximately normally distributed variables. With the presented method of a vector analysis made out of waveform samples acquired with four thresholds, we obtain a spatial resolution of about 1 cm and a timing resolution of about 80 p

    Search for Deeply Bound Kaonic Nuclear States with AMADEUS

    Full text link
    We briefly report on the search for Deeply Bound Kaonic Nuclear States with AMADEUS in the Sigma0 p channel following K- absorption on 12C and outline future perspectives for this work
    corecore