836 research outputs found

    Superballistic Diffusion of Entanglement in Disordered Spin Chains

    Full text link
    We study the dynamics of a single excitation in an infinite XXZ spin chain, which is launched from the origin. We study the time evolution of the spread of entanglement in the spin chain and obtain an expression for the second order spatial moment of concurrence, about the origin, for both ordered and disordered chains. In this way, we show that a finite central disordered region can lead to sustained superballistic growth in the second order spatial moment of entanglement within the chain.Comment: 5 pages, 1 figur

    Automated precision alignment of optical components for hydroxide catalysis bonding

    Get PDF
    We describe an interferometric system that can measure the alignment and separation of a polished face of a optical component and an adjacent polished surface. Accuracies achieved are ∼ 1μrad for the relative angles in two orthogonal directions and ∼ 30μm in separation. We describe the use of this readout system to automate the process of hydroxide catalysis bonding of a fused-silica component to a fused-silica baseplate. The complete alignment and bonding sequence was typically achieved in a timescale of a few minutes, followed by an initial cure of 10 minutes. A series of bonds were performed using two fluids - a simple sodium hydroxide solution and a sodium hydroxide solution with some sodium silicate solution added. In each case we achieved final bonded component angular alignment within 10 μrad and position in the critical direction within 4 μm of the planned targets. The small movements of the component during the initial bonding and curing phases were monitored. The bonds made using the sodium silicate mixture achieved their final bonded alignment over a period of ∼ 15 hours. Bonds using the simple sodium hydroxide solution achieved their final alignment in a much shorter time of a few minutes. The automated system promises to speed the manufacture of precision-aligned assemblies using hydroxide catalysis bonding by more than an order of magnitude over the more manual approach used to build the optical interferometer at the heart of the recent ESA LISA Pathfinder technology demonstrator mission. This novel approach will be key to the time-efficient and low-risk manufacture of the complex optical systems needed for the forthcoming ESA spaceborne gravitational waves observatory mission, provisionally named LISA

    Construction of rugged, ultrastable optical assemblies with optical component alignment at the few microradian level

    Get PDF
    A method for constructing quasimonolithic, precision-aligned optical assemblies is presented. Hydroxide-catalysis bonding is used, adapted to allow optimization of component fine alignment prior to the bond setting. We demonstrate the technique by bonding a fused silica mirror substrate to a fused silica baseplate. In-plane component placement at the submicrometer level is achieved, resulting in angular control of a reflected laser beam at the sub-10-μrad level. Within the context of the LISA Pathfinder mission, the technique has been demonstrated as suitable for use in space-flight applications. It is expected that there will also be applications in a wide range of areas where accuracy, stability, and strength of optical assemblies are important

    Construction and testing of the optical bench for LISA pathfinder

    Get PDF
    eLISA is a space mission designed to measure gravitational radiation over a frequency range of 0.1–100 mHz (European Space Agency LISA Assessment Study Report 2011). It uses laser interferometry to measure changes of order 10pm/Hz10\,{\rm pm /\sqrt{Hz}} in the separation of inertial test masses housed in spacecraft separated by 1 million km. LISA Pathfinder (LPF) is a technology demonstrator mission that will test the key eLISA technologies of inertial test masses monitored by laser interferometry in a drag-free spacecraft. The optical bench that provides the interferometry for LPF must meet a number of stringent requirements: the optical path must be stable at the few pm/Hz{\rm pm /\sqrt{Hz}} level; it must direct the optical beams onto the inertial masses with an accuracy of better than ±25 μm, and it must be robust enough not only to survive launch vibrations but to achieve full performance after launch. In this paper we describe the construction and testing of the flight optical bench for LISA Pathfinder that meets all the design requirements

    Mechanisation of Precision Placement and Catalysis Bonding of Optical Components

    Get PDF
    Precision-aligned, ultra-stable optical assemblies are needed for an increasing number of space applications, in areas such as science, metrology and geodesy

    Sub-system mechanical design for an eLISA optical bench

    Get PDF
    We present the design and development status of the opto-mechanical sub-systems that will be used in an experimental demonstration of imaging systems for eLISA. An optical bench test bed design incorporates a Zerodur® baseplate with lenses, photodetectors, and other opto-mechanics that must be both adjustable - with an accuracy of a few micrometers - and stable over a 0 to 40°C temperature range. The alignment of a multi-lens imaging system and the characterisation of the system in multiple degrees of freedom is particularly challenging. We describe the mechanical design of the precision mechanisms, including thermally stable flexure-based optical mounts and complex multi-lens, multi-axis adjuster mechanisms, and update on the integration of the mechanisms on the optical bench

    Cross-verification of independent quantum devices

    Full text link
    Quantum computers are on the brink of surpassing the capabilities of even the most powerful classical computers. This naturally raises the question of how one can trust the results of a quantum computer when they cannot be compared to classical simulation. Here we present a verification technique that exploits the principles of measurement-based quantum computation to link quantum circuits of different input size, depth, and structure. Our approach enables consistency checks of quantum computations within a device, as well as between independent devices. We showcase our protocol by applying it to five state-of-the-art quantum processors, based on four distinct physical architectures: nuclear magnetic resonance, superconducting circuits, trapped ions, and photonics, with up to 6 qubits and 200 distinct circuits

    Azelastine potentiates antiasthmatic dexamethasone effect on a murine asthma model

    Get PDF
    Glucocorticoids are among the most effective drugs to treat asthma. However, thesevere adverse effects associated generate the need for its therapeutic optimization. Conversely, though histamine is undoubtedly related to asthma development, there is a lack of efficacy of antihistamines in controlling its symptoms, which prevents their clinical application. We have reported that antihistamines potentiate glucocorticoids? responses in vitro and recent observations have indicated that the coadministration of an antihistamine and a synthetic glucocorticoid has synergistic effects on a murine model of allergic rhinitis. Here, the aim of this work is to establish if this therapeutic combination could be beneficial in a murine model of asthma. We used an allergen‐induced model of asthma (employing ovalbumin) to evaluate the effectsof the synthetic glucocorticoid dexamethasone combined with the antihistamineazelastine. Our results indicate that the cotreatment with azelastine and a suboptimal dose of dexamethasone can improve allergic lung inflammation as shown by a decrease in eosinophils in bronchoalveolar lavage, fewer peribronchial and perivascular infiltrates, and mucin‐producing cells. In addition, serum levels of allergen‐specific IgE and IgG1 were also reduced, as well as the expression of lung inflammatory‐related genes IL‐4, IL‐5, Muc5AC, and Arginase I. The potentiation of dexamethasone effects by azelastine could allow to reduce the effective glucocorticoid dose needed to achieve a therapeutic effect. These findings provide first new insights into the potential benefits of glucocorticoids and antihistamines combination for the treatment of asthma and grants further research to evaluate this approach in other related inflammatory conditions.Fil: Zappia, Carlos Daniel. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Farmacológicas. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Investigaciones Farmacológicas; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Farmacológicas. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Investigaciones Farmacológicas; ArgentinaFil: Soto, Ariadna Soledad. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Granja Galeano, Gina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Farmacológicas. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Investigaciones Farmacológicas; ArgentinaFil: Fenoy, Ignacio Martín. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; ArgentinaFil: Fernandez, Natalia Cristina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Farmacológicas. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Investigaciones Farmacológicas; ArgentinaFil: Davio, Carlos Alberto. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Farmacológicas. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Investigaciones Farmacológicas; ArgentinaFil: Shayo, Carina Claudia. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Biología y Medicina Experimental. Fundación de Instituto de Biología y Medicina Experimental. Instituto de Biología y Medicina Experimental; ArgentinaFil: Fitzsimons, Carlos P.. University of Amsterdam; Países BajosFil: Goldman, Alejandra. Universidad Nacional de San Martín. Escuela de Ciencia y Tecnología. Centro de Estudios en Salud y Medio Ambiente; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Monczor, Federico. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay. Instituto de Investigaciones Farmacológicas. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica. Instituto de Investigaciones Farmacológicas; Argentin

    Design and construction of an optical test bed for LISA imaging systems and tilt-to-length coupling

    Get PDF
    The laser interferometer space antenna (LISA) is a future space-based interferometric gravitational-wave detector consisting of three spacecraft in a triangular configuration. The interferometric measurements of path length changes between satellites will be performed on optical benches in the satellites. Angular misalignments of the interfering beams couple into the length measurement and represent a significant noise source. Imaging systems will be used to reduce this tilt-to-length coupling. We designed and constructed an optical test bed to experimentally investigate tilt-to-length coupling. It consists of two separate structures, a minimal optical bench and a telescope simulator. The minimal optical bench comprises the science interferometer where the local laser is interfered with light from a remote spacecraft. In our experiment, a simulated version of this received beam is generated on the telescope simulator. The telescope simulator provides a tilting beam, a reference interferometer and an additional static beam as a phase reference. The tilting beam can either be a flat-top beam or a Gaussian beam. We avoid tilt-to-length coupling in the reference interferometer by using a small photo diode placed at an image of the beam rotation point. We show that the test bed is operational with an initial measurement of tilt-to-length coupling without imaging systems. Furthermore, we show the design of two different imaging systems whose performance will be investigated in future experiments
    corecore