262 research outputs found

    First Beam Based Aperture Measurements in the Arcs of the CERN Large Hadron Collider

    Get PDF
    The LHC injection tests performed in August and early September 2008 in preparation for the circulating beam operation provided the first opportunity to measure with beam the mechanical aperture in two LHC sectors (2-3 and 7- 8). The aperture was probed by exciting free oscillations and local orbit bumps of the injected beam trajectories. Intensities of a few 109 protons were used to remain safely below the quench limit of superconductingmagnets in case of beam losses. The methods used to measure the mechanical aperture, the available on-line tools, and beam measurements for both sectors are presented. Detailed comparisons with the expected results from the as-built aperture models are also presented. It is shown that the measurements results are in good agreement with the LHC design aperture

    Dynamic beam based calibration of orbit monitors at LEP

    Get PDF
    The offsets of the beam position monitors (BOM) with respect to the centre of the quadrupoles were determined for 16 wide band electronic and 18 narrow band electronic monitors. The first are located near to the IPs and the latter are in all other parts. The distribution of the wide band monitor offsets at the low beta focusing quadrupole magnets has a mean value of 1000 µm and a width of s = 600 mm. The offsets are almost identical with the beam position of the orbit which allows to obtain highest luminosity. The distribution of the narrow band monitor offsets has a mean value of 19 mm and a width of s = 245 mm

    Development, Production and Testing of 4500 Beam Loss Monitors

    Get PDF
    Beam-loss monitoring (BLM) [1] is a key element in the LHC machine protection. 4250 nitrogen filled ionization chambers (IC) and 350 secondary emission monitors (SEM) have been manufactured and tested at the Institute for High Energy Physics (IHEP) in Protvino, Russia, following their development at CERN. Signal speed and robustness against aging were the main design criteria. Each monitor is permanently sealed inside a stainless-steel cylinder. The quality of the welding was a critical aspect during production. The SEMs are requested to hold a vacuum of 10710^{-7} bar. Impurity levels from thermal and radiationinduced desorption should remain in the range of parts per million in the ICs. To avoid radiation aging (up to 2A^1082·10^{8} Gy in 20 years) production of the chambers followed strict UHV requirements. IHEP designed and built the UHV production stand. Due to the required dynamic range of 10810^{8}, the leakage current of the monitors has to stay below 2 pA. Several tests during and after production were performed at IHEP and CERN. A consistently high quality during the whole production period was achieved and the tight production schedule kept at the same time

    Requirements for the LHC collimation system

    Get PDF
    The LHC requires efficient collimation during all phases of the beam cycle. Collimation plays important roles in prevention of magnet quenches from regular beam diffusion, detection of abnormal beam loss and subsequent beam abort, radiation protection, and passive protection of the superconducting magnets in case of failures. The different roles of collimation and the high beam power in the LHC impose many challenges for the design of the collimation system. In particular, the collimators must be able to withstand the expected particle losses. The requirements for the LHC collimation system are presented

    Status of the LEP2 Spectrometer Project

    Get PDF
    The LEP spectrometer has been conceived to provide a determination of the beam energy with a relative accuracy of 10-4 in the LEP2 physics region where insufficient polarisation levels prevent the application of the resonant depolarisation method. The setup consists of a steel bending magnet flanked by a triplet of Beam Position Monitors (BPM) at each side providing a measurement of changes in the bending angle when the beams are accelerated to physics energies. The goal for a 100 ppm relative precision on the beam energy involves a ± 1 micron BPM resolution and the calibration of the dipole bending strength to a 30 ppm accuracy. This paper reports on the results of the commissioning of the Spectrometer during the 1999 LEP Run and on the experience acquired on the behaviour of the several sub-systems with circulating beams

    The LHC Injection Tests

    Get PDF
    A series of LHC injection tests was performed in August and September 2008. The first saw beam injected into sector 23; the second into sectors 78 and 23; the third into sectors 78-67 and sectors 23-34-45. The fourth, into sectors 23-34-45, was performed the evening before the extended injection test on the 10th September which saw both beams brought around the full circumference of the LHC. The tests enabled the testing and debugging of a number of critical control and hardware systems; testing and validation of instrumentation with beam for the first time; deployment, and validation of a number of measurement procedures. Beam based measurements revealed a number of machine configuration issues that were rapidly resolved. The tests were undoubtedly an essential precursor to the successful start of LHC beam commissioning. This paper provides an outline of preparation for the tests, the machine configuration and summarizes the measurements made and individual system performance

    Altered monocyte activation markers in Tourette's syndrome: a case-control study

    Get PDF
    Background: Infections and immunological processes are likely to be involved in the pathogenesis of Tourette's syndrome (TS). To determine possible common underlying immunological mechanisms, we focused on innate immunity and studied markers of inflammation, monocytes, and monocyte-derived cytokines. Methods: In a cross-sectional study, we used current methods to determine the number of monocytes and levels of C-reactive protein (CRP) in 46 children, adolescents, and adult patients suffering from TS and in 43 healthy controls matched for age and sex. Tumor necrosis factor alpha (TNF-alpha), interleukin 6 (IL-6), soluble CD14 (sCD14), IL1-receptor antagonist (IL1-ra), and serum neopterin were detected by immunoassays. Results: We found that CRP and neopterin levels and the number of monocytes were significantly higher in TS patients than in healthy controls. Serum concentrations of TNF-alpha, sIL1-ra, and sCD14 were significantly lower in TS patients. All measured values were within normal ranges and often close to detection limits. Conclusions: The present results point to a monocyte dysregulation in TS. This possible dysbalance in innate immunity could predispose to infections or autoimmune reactions

    (Per)chlorate reduction by an acetogenic bacterium, Sporomusa sp., isolated from an underground gas storage

    Get PDF
    A mesophilic bacterium, strain An4, was isolated from an underground gas storage reservoir with methanol as substrate and perchlorate as electron acceptor. Cells were Gram-negative, spore-forming, straight to curved rods, 0.5–0.8 μm in diameter, and 2–8 μm in length, growing as single cells or in pairs. The cells grew optimally at 37°C, and the pH optimum was around 7. Strain An4 converted various alcohols, organic acids, fructose, acetoin, and H2/CO2 to acetate, usually as the only product. Succinate was decarboxylated to propionate. The isolate was able to respire with (per)chlorate, nitrate, and CO2. The G+C content of the DNA was 42.6 mol%. Based on the 16S rRNA gene sequence analysis, strain An4 was most closely related to Sporomusa ovata (98% similarity). The bacterium reduced perchlorate and chlorate completely to chloride. Key enzymes, perchlorate reductase and chlorite dismutase, were detected in cell-free extracts

    The effects of Gilles de la Tourette syndrome and other chronic tic disorders on quality of life across the lifespan:a systematic review

    Get PDF
    Gilles de la Tourette syndrome (GTS) and other chronic tic disorders are neurodevelopmental conditions characterized by the presence of tics and associated behavioral problems. Whilst converging evidence indicates that these conditions can affect patients' quality of life (QoL), the extent of this impairment across the lifespan is not well understood. We conducted a systematic literature review of published QoL studies in GTS and other chronic tic disorders to comprehensively assess the effects of these conditions on QoL in different age groups. We found that QoL can be perceived differently by child and adult patients, especially with regard to the reciprocal contributions of tics and behavioral problems to the different domains of QoL. Specifically, QoL profiles in children often reflect the impact of co-morbid attention-deficit and hyperactivity symptoms, which tend to improve with age, whereas adults' perception of QoL seems to be more strongly affected by the presence of depression and anxiety. Management strategies should take into account differences in age-related QoL needs between children and adults with GTS or other chronic tic disorders
    corecore