19 research outputs found

    Evidence-based hydro- and balneotherapy in Hungary-a systematic review and meta-analysis

    Get PDF
    Balneotherapy is appreciated as a traditional treatment modality in medicine. Hungary is rich in thermal mineral waters. Balneotherapy has been in extensive use for centuries and its effects have been studied in detail. Here, we present a systematic review and meta-analysis of clinical trials conducted with Hungarian thermal mineral waters, the findings of which have been published by Hungarian authors in English. The 122 studies identified in different databases include 18 clinical trials. Five of these evaluated the effect of hydro- and balneotherapy on chronic low back pain, four on osteoarthritis of the knee, and two on osteoarthritis of the hand. One of the remaining seven trials evaluated balneotherapy in chronic inflammatory pelvic diseases, while six studies explored its effect on various laboratory parameters. Out of the 18 studies, 9 met the predefined criteria for meta-analysis. The results confirmed the beneficial effect of balneotherapy on pain with weight bearing and at rest in patients with degenerative joint and spinal diseases. A similar effect has been found in chronic pelvic inflammatory disease. The review also revealed that balneotherapy has some beneficial effects on antioxidant status, and on metabolic and inflammatory parameters. Based on the results, we conclude that balneotherapy with Hungarian thermal-mineral waters is an effective remedy for lower back pain, as well as for knee and hand osteoarthritis. © 2013 The Author(s)

    Standards of Care for the Health of Transgender and Gender Diverse People, Version 8

    Full text link
    Background: Transgender healthcare is a rapidly evolving interdisciplinary field. In the last decade, there has been an unprecedented increase in the number and visibility of transgender and gender diverse (TGD) people seeking support and gender-affirming medical treatment in parallel with a significant rise in the scientific literature in this area. The World Professional Association for Transgender Health (WPATH) is an international, multidisciplinary, professional association whose mission is to promote evidence-based care, education, research, public policy, and respect in transgender health. One of the main functions of WPATH is to promote the highest standards of health care for TGD people through the Standards of Care (SOC). The SOC was initially developed in 1979 and the last version (SOC-7) was published in 2012. In view of the increasing scientific evidence, WPATH commissioned a new version of the Standards of Care, the SOC-8. Aim: The overall goal of SOC-8 is to provide health care professionals (HCPs) with clinical guidance to assist TGD people in accessing safe and effective pathways to achieving lasting personal comfort with their gendered selves with the aim of optimizing their overall physical health, psychological well-being, and self-fulfillment. Methods: The SOC-8 is based on the best available science and expert professional consensus in transgender health. International professionals and stakeholders were selected to serve on the SOC-8 committee. Recommendation statements were developed based on data derived from independent systematic literature reviews, where available, background reviews and expert opinions. Grading of recommendations was based on the available evidence supporting interventions, a discussion of risks and harms, as well as the feasibility and acceptability within different contexts and country settings. Results: A total of 18 chapters were developed as part of the SOC-8. They contain recommendations for health care professionals who provide care and treatment for TGD people. Each of the recommendations is followed by explanatory text with relevant references. General areas related to transgender health are covered in the chapters Terminology, Global Applicability, Population Estimates, and Education. The chapters developed for the diverse population of TGD people include Assessment of Adults, Adolescents, Children, Nonbinary, Eunuchs, and Intersex Individuals, and people living in Institutional Environments. Finally, the chapters related to gender-affirming treatment are Hormone Therapy, Surgery and Postoperative Care, Voice and Communication, Primary Care, Reproductive Health, Sexual Health, and Mental Health. Conclusions: The SOC-8 guidelines are intended to be flexible to meet the diverse health care needs of TGD people globally. While adaptable, they offer standards for promoting optimal health care and guidance for the treatment of people experiencing gender incongruence. As in all previous versions of the SOC, the criteria set forth in this document for gender-affirming medical interventions are clinical guidelines; individual health care professionals and programs may modify these in consultation with the TGD person

    Prise en charge des voies aériennes – 1re partie – Recommandations lorsque des difficultés sont constatées chez le patient inconscient/anesthésié

    Get PDF

    Evaluation of the GlideScope for tracheal intubation in patients with cervical spine immobilisation by a semi-rigid collar

    Get PDF
    RAPPORT DE SYNTHÈSE : Chez les patients présentant une pathologie de la colonne cervicale, l'instrumentation des voies aériennes peut s'avérer délicate. En effet, l'impossibilité d'effectuer une extension de la nuque afin d'aligner correctement l'axe oro-pharyngo-trachéal, ainsi que l'ouverture de bouche limitée par la présence d'une minerve cervicale, rendent la laryngoscopie standard extrêmement difficile. Le but de cette étude est de démontrer que l'intubation oro-trachéale avec une minerve cervicale semi-rigide est possible à l'aide d'un vidéolaryngoscope récemment développé, le GlideScope®. Celui-ci est formé d'une lame courbe présentant une angulation accentuée à 60° à partir de son milieu, avec une petite caméra haute résolution et une source lumineuse enchâssées dans la partie inférieure au point d'inflexion. Différents travaux ont montré les avantages du GlideScope® par rapport à la lame de Macintosh standard "pour l'instrumentation des voies aériennes de routine ou en situation difficile. Après acceptation par la Commission d'Ethique, 50 patients, adultes consentants et programmés pour une intervention chirurgicale élective nécessitant une anesthésie générale ont été inclus dans cette étude. Malgré la présence d'une minerve cervicale semi-rigide Philadelphia® Patriot correctement positionnée et la tête fixée à la table d'opération, tous les patients ont pu être intubés a l'aide du GlideScope®. Aucune complication n'a été documentée pendant la procédure ou en post-opératoire. De plus, nous avons démontré que dans cette situation la visualisation des structures laryngées est significativement améliorée grâce au GlideScope®, par rapport à la lame de Macintosh utilisée lors de toute intubation standard. En conclusion, l'intubation oro-trachéale chez les patients ayant une minerve cervicale et la tête fixée est possible à l'aide du GlideScope®. La meilleure façon de sécuriser les voies aériennes chez les patients présentant une instabilité de la colonne cervicale est un sujet fortement débattu. L'utilisation du GlideScope® pourrait s'avérer une alternative intéressante, en particulier dans les situations d'urgence

    Evaluation of the GlideScope (R) for tracheal intubation in patients with cervical spine immobilization by a semi-rigid collar

    No full text
    Background: In patients with cervical spine injury, a cervical collar may prevent cervical spine movements but renders tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesized that despite the presence of a semi-rigid cervical collar and with the patient's head taped to the trolley, we would be able to intubate all patients with the GlideScopeR and its dedicated stylet. Methods: 50 adult patients (ASA 1 or 2, BMI ≤35 kg/m2) scheduled for elective surgical procedures requiring tracheal intubation were included. After standardized induction of general anesthesia and neuromuscular blockade, the neck was immobilized with an appropriately sized semi-rigid Philadelphia Patriot® cervical collar, the head was taped to the trolley. Laryngoscopy was attempted using a Macintosh laryngoscope blade 4 and the modified Cormack Lehane grade was noted. Subsequently, laryngoscopy with the GlideScopeR was graded and followed by oro-tracheal intubation. Results: All patients were successfully intubated with the GlideScopeR and its dedicated stylet. The median intubation time was 50 sec [43; 61]. The modified Cormack Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScopeR (p <0.0001), reaching 2a in most of patients. Maximal mouth opening was significantly reduced with the cervical collar applied, 4.5 cm [4.5; 5.0] vs. 2.0 cm [1.8; 2.0] (p <0.0001). Conclusions: The GlideScope® allows oro-tracheal intubation in patients having their cervical spine immobilized by a semi-rigid collar and their head taped to the trolley. It furthermore decreases significantly the modified Cormack Lehane grade

    Use of the nasotracheal Airtraq to assist difficult nasal fibreoptic intubation.

    No full text

    Evaluation of the Video Intubation Unit in morbid obese patients.

    No full text
    BACKGROUND: Tracheal intubation may be more difficult in morbidly obese (MO) patients than in the non-obese. The aim of this study was to evaluate clinically if the use of the Video Intubation Unit (VIU), a video-optical intubation stylet, could improve the laryngoscopic view compared with the standard Macintosh laryngoscope in this specific population. METHODS: We studied 40 MO patients (body mass index >35 kg/m(2)) scheduled for bariatric surgery. Each patient had a conventional laryngoscopy and a VIU inspection. The laryngoscopic grades (LG) using the Cormack and Lehane scoring system were noted and compared. Thereafter, the patients were randomised to be intubated with one of the two techniques. In one group, the patients were intubated with the help of the VIU and in the control group, tracheal intubation was performed conventionally. The duration of intubation, as well as the minimal SpO(2) achieved during the procedure, were measured. RESULTS: Patient characteristics were similar in both groups. Seventeen patients had a direct LG of 2 or 3 (no patient had a grade of 4). Out of these 17 patients, the LG systematically improved with the VIU and always attained grade 1 (P<0.0001). The intubation time was shorter within the VIU group, but did not attain significance. There was no difference in the SpO(2) post-intubation. CONCLUSION: In MO patients, the use of the VIU significantly improves the visualisation of the larynx, thereby improving the intubation conditions

    Comparing S-Guide® and Gliderite® Times to Assist Video laryngoscopic Intubation in Patients with Simulated Difficult Airways: A Single-Blinded Randomized Prospective Study.

    No full text
    Gliderite®, one of the first stylets designed specifically to assist tracheal intubation with non-channeled curved blades video laryngoscopes, can cause injury. The S-Guide® is a new, malleable, intubating guide allowing oxygenation. Its soft tip is designed to prevent trauma. We aimed to compare the duration of tracheal intubation with S-Guide compared to Gliderite using a C-MAC® D-Blade® video laryngoscope in patients with simulated difficult airways. We performed a single-blinded prospective randomized study, with 50 adult patients requiring orotracheal intubation under general anaestheesia in Lausanne University Hospital. A cervical collar was fitted around the patient's neck to simulate difficult intubation conditions. Exclusion criteria were American Society of Anesthesiologists (ASA) >3, BMI > 35 kg m2 , known or at risk of difficult intubation, and risk of aspiration of gastric content. We recorded T1: time of identification of the glottis; T2: time to inflate the cuff, and T3: total intubation time (capnography curve appearance). Secondary outcomes were the presence of arytenoid contact during intubation and postoperative airway discomfort. There were no significant differences between T1 and T2 (seconds) while using the S-Guide or Gliderite, respectively: 14.6 [9.6- 18.6] vs 16.5 [11.0-20.6]; P=.368 and 43.3 [33.2-49.3] vs 46.3 [35.6-61.5], P =.308. T3 was significantly shorter in the S-Guide group: 58.1 [50.2-61.8] vs 65.3 [57.6-78.7], P =.044. Fewer arytenoid contact occurred during intubation using the S-Guide (P =.032), without difference in postoperative airway discomfort. S-Guide-assisted tracheal intubation, with a C-MAC D-Blade in simulated difficult airways, allows successful and faster intubation than with the Gliderite Stylet

    Electrophysiological Study of Femoral Nerve Function After a Continuous Femoral Nerve Block for Anterior Cruciate Ligament Reconstruction.

    No full text
    A continuous femoral nerve block (CFNB) is an effective analgesic treatment after anterior cruciate ligament (ACL) reconstruction but may result in transient femoral nerve injuries and quadriceps muscle weakness, which in turn contribute to worsened functional outcomes. To compare electrophysiological criteria of a femoral nerve injury as well as functional and pain-related outcomes after ACL reconstruction when analgesia was provided by a CFNB or intravenous patient-controlled analgesic of morphine (IV PCA). Randomized controlled clinical trial; Level of evidence, 1. A total of 74 patients scheduled for ACL reconstruction were randomized to receive a CFNB before surgery, followed by a ropivacaine infusion for 2 days and oxycodone, or IV PCA. The primary outcome was the rate of femoral nerve injuries at 4 weeks postoperatively, defined as a reduction of the compound muscle action potential (CMAP) area from the vastus medialis muscle after supramaximal femoral nerve stimulation at the groin, associated with an absent H-reflex of the femoral nerve and signs of vastus medialis muscle denervation. Secondary functional outcomes were quadriceps muscle strength, active flexion range, and distance walked, as measured on postoperative days 1 and 2. Secondary pain-related outcomes were IV morphine consumption and pain scores at rest and on movement in phase 1 recovery and on postoperative days 1 and 2. No patients met the electrophysiological criteria of a femoral nerve injury. The mean CMAP area at 4 weeks was equivalent in both the CFNB and IV PCA groups (47 ± 16 mV·ms and 51 ± 13 mV·ms, respectively; P = .50). While no differences were detected in functional outcomes or pain scores, the consumption of an IV morphine equivalent was reduced by the administration of a CFNB in phase 1 recovery (6 ± 5 mg and 13 ± 7 mg, respectively; P = .0003), on postoperative day 1 (6 ± 7 mg and 19 ± 17 mg, respectively; P = .0005), and on postoperative day 2 (11 ± 10 mg and 19 ± 17 mg, respectively; P = .03) compared with an IV PCA. Despite prior contrary reports, a CFNB did not result in femoral nerve injuries or worsened functional outcomes after ACL reconstruction. The improvement of analgesia with a CFNB was only marginal and not clinically relevant beyond 24 hours. Registration: NCT01321138 ( ClinicalTrials.gov identifier)

    Endotracheal tube displacement during head and neck movements. Observational clinical trial.

    No full text
    Measure the displacements of endotracheal tube (ETT) tip displacement during head and neck movements. Observational study. Ear-nose-throat (ENT) and neurosurgery operating room. We performed a maximal head-neck movement trial on 50 adult patients, American Society of Anaesthesiologists 1 or 2. Patients with body mass index >35 kg · m(-2), height <150 cm, airway malformations, pulmonary diseases, difficulties in neck flexion or extension, previous ENT surgery or radiotherapy, gastroesophageal reflux, or dental instability were excluded from the study. ENT and neurosurgery. We measured the change in distance between the ETT tip and the carina, using a fiberscope through the ETT. After intubation, a wide disparity of tube tip distance to the carina in the neutral position was noted with a median of 5.0 (3.5-7.0) cm. Cephalad tube movement was documented following maximal head and neck extension in 34 (68%) patients and right head rotation in 25 patients (50%). Caudal tube displacement was due to maximal head and neck flexion in 38 patients (76%) and left head rotation in 25 patients (50%). Selective right main bronchus intubation was noted in 2 (4%) patients after maximal head extension. Maximal head and neck movements led to unpredictable tube displacements. Proper reassessment of tube positioning after head and neck movement of intubated patients is therefore mandatory
    corecore