144 research outputs found

    Electrospun polymer nanofibers: the booming cutting edge technology

    Get PDF
    Electrospinning has been recognized as a simple and efficient technique for the fabrication of ultrathin fibers from a variety of materials including polymers, composite and ceramics. Significant progress has been made throughout the past years in electrospinning and the resulting fibrous structures have been exploited in a wide range of potential applications. This article reviews the state-of-art of electrospinning to prepare fibrous electrode materials and polymer electrolytes based on electrospun membranes in the view of their physical and electrochemical properties for the application in lithium batteries. The review covers the electrospinning process, the governing parameters and their influence on fiber or membrane morphology. After a brief discussion of some potential applications associated with the remarkable features of electrospun membranes, we highlight the exploitation of this cutting edge technology in lithium batteries. Finally the article is concluded with some personal perspectives on the future directions in the fascinating field of energy storag

    Structural characterization and electrochemical properties of Co3O4 anode materials synthesized by a hydrothermal method

    Get PDF
    Cobalt oxide [Co3O4] anode materials were synthesized by a simple hydrothermal process, and the reaction conditions were optimized to provide good electrochemical properties. The effect of various synthetic reaction and heat treatment conditions on the structure and electrochemical properties of Co3O4 powder was also studied. Physical characterizations of Co3O4 are investigated by X-ray diffraction, scanning electron microscopy, and Brunauer-Emmett-Teller [BET] method. The BET surface area decreased with values at 131.8 m2/g, 76.1 m2/g, and 55.2 m2/g with the increasing calcination temperature at 200°C, 300°C, and 400°C, respectively. The Co3O4 particle calcinated at 200°C for 3 h has a higher surface area and uniform particle size distribution which may result in better sites to accommodate Li+ and electrical contact and to give a good electrochemical property. The cell composed of Super P as a carbon conductor shows better electrochemical properties than that composed of acetylene black. Among the samples prepared under different reaction conditions, Co3O4 prepared at 200°C for 10 h showed a better cycling performance than the other samples. It gave an initial discharge capacity of 1,330 mAh/g, decreased to 779 mAh/g after 10 cycles, and then showed a steady discharge capacity of 606 mAh/g after 60 cycles

    Patterned Si thin film electrodes for enhancing structural stability

    Get PDF
    A patterned film (electrode) with lozenge-shaped Si tiles could be successfully fabricated by masking with an expanded metal foil during film deposition. Its electrochemical properties and structural stability during the charge-discharge process were examined and compared with those of a continuous (conventional) film electrode. The patterned electrode exhibited a remarkably improved cycleability (75% capacity retention after 120 cycles) and an enhanced structural stability compared to the continuous electrode. The good electrochemical performance of the patterned electrode was attributed to the space between Si tiles that acted as a buffer against the volume change of the Si electrode

    A two-photon fluorescent probe for lysosomal zinc ions

    Get PDF
    The selective detection of zinc ions in lysosomes over that in cytosol is achieved with a fluorescent probe, which enabled the fluorescence imaging of endogenous zinc ions in lysosomes of NIH 3T3 cells as well as mouse hippocampal tissues by two-photon microscopy under excitation at 900 nm.open

    Validation of a Novel Endoscopic Feature that Predicts Helicobacter pylori-negative Status: Does the Scratch Sign Reflect H. pylori Non-infection?

    Get PDF
    Background/Aims Identification of Helicobacter pylori infection status is necessary as H. pylori is associated with gastric malignancy. Recently, a red linear scrape-like appearance on the gastric mucosa, called the “scratch sign,” was reported to be associated with H. pylori-negative gastric mucosal status. Herein, we aimed to validate the association between the scratch sign and H. pylori infection status. Methods The data of patients who underwent screening endoscopy at Bundang Jesaeng General Hospital between March 2023 and April 2023 were reviewed. Patients were classified as having an H. pylori current infection or non-infection status based on the results of rapid urease tests. Patients who had undergone H. pylori eradication therapy were excluded. Endoscopic features of the gastric mucosa were assessed using the Kyoto classification of gastritis. Results The scratch sign appeared more frequently in patients with non-infection than in those with current infection status (32.7% vs. 10.6%, respectively; P<0.001). Multivariate analysis showed that only the presence of sticky mucus was significantly associated with the presence of the scratch sign. Patient without the scratch sign had a higher prevalence of open-type atrophy, intestinal metaplasia, enlarged folds, and diffuse redness, which reflected a higher Kyoto score. Conclusions Presence of the gastric mucosal scratch sign, a novel endoscopic marker, is indicative of H. pylori-negative status and appears to be inversely correlated with the presence of sticky mucus. In addition to the Kyoto classification of gastritis, detection of the scratch sign may facilitate identification of the H. pylori infection status

    Stent Fracture at the Proximal Shaft of the Left Main Stem

    Get PDF
    Stent fracture is likely to be caused due to mechanical stress at the hinge point or kinking movement at the point of aneurysm formation with stent malapposition. To our knowledge, this is the first published report of stent fracture at the proximal shaft of the left main stem in a patient with acute myocardial infarction

    Exercise and the Risk of Dementia in Patients with Newly Diagnosed Atrial Fibrillation: A Nationwide Population-Based Study

    Get PDF
    Background: It is unclear whether exercise would reduce dementia in patients with a new diagnosis of atrial fibrillation (AF). Therefore, we aimed to evaluate the association between the change in physical activity (PA) before and after new-onset AF and the risk of incident dementia. Methods: Using the Korean National Health Insurance Service database, we enrolled a total of 126,555 patients with newly diagnosed AF between 2010 and 2016, who underwent health examinations within two years before and after their diagnosis of AF. The patients were divided into four groups: persistent non-exercisers, exercise starters, exercise quitters, and exercise maintainers. Results: Based on a total of 396,503 person-years of follow-up, 5943 patients were diagnosed with dementia. Compared to persistent non-exercisers, exercise starters (adjusted hazard ratio (aHR) 0.87; 95% confidence interval (CI) 0.81–0.94), and exercise maintainers (aHR 0.66; 95% CI 0.61–0.72) showed a lower risk of incident dementia; however, the risk was similar in exercise quitters (aHR 0.98; 95% CI 0.92–1.05) (p-trend < 0.001). There was a J-shaped relationship between the dose of exercise and the risk of dementia, with the risk reduction maximized at 5–6 times per week of moderate-to-vigorous PA among exercise starters. Conclusion: Patients who initiated or continued regular exercise after diagnosis of AF were associated with a lower risk of dementia than persistent non-exercisers, with no risk reduction associated with exercise cessation. Our findings may provide evidence for the benefit of exercise prescription to patients with new-onset AF to prevent incident dementia regardless of their current exercise status

    Association between exercise habits and stroke, heart failure, and mortality in Korean patients with incident atrial fibrillation: A nationwide population-based cohort study

    Get PDF
    BackgroundThere is a paucity of information about cardiovascular outcomes related to exercise habit change after a new diagnosis of atrial fibrillation (AF). We investigated the association between exercise habits after a new AF diagnosis and ischemic stroke, heart failure (HF), and all-cause death.Methods and findingsThis is a nationwide population-based cohort study using data from the Korea National Health Insurance Service. A retrospective analysis was performed for 66,692 patients with newly diagnosed AF between 2010 and 2016 who underwent 2 serial health examinations within 2 years before and after their AF diagnosis. Individuals were divided into 4 categories according to performance of regular exercise, which was investigated by a self-reported questionnaire in each health examination, before and after their AF diagnosis: persistent non-exercisers (30.5%), new exercisers (17.8%), exercise dropouts (17.4%), and exercise maintainers (34.2%). The primary outcomes were incidence of ischemic stroke, HF, and all-cause death. Differences in baseline characteristics among groups were balanced considering demographics, comorbidities, medications, lifestyle behaviors, and income status. The risks of the outcomes were computed by weighted Cox proportional hazards models with inverse probability of treatment weighting (IPTW) during a mean follow-up of 3.4 ± 2.0 years. The new exerciser and exercise maintainer groups were associated with a lower risk of HF compared to the persistent non-exerciser group: the hazard ratios (HRs) (95% CIs) were 0.95 (0.90-0.99) and 0.92 (0.88-0.96), respectively (p ConclusionsInitiating or continuing regular exercise after AF diagnosis was associated with lower risks of HF and mortality. The promotion of exercise might reduce the future risk of adverse outcomes in patients with AF
    corecore