1,793 research outputs found
Design and standalone characterisation of a capacitively coupled HV-CMOS sensor chip for the CLIC vertex detector
The concept of capacitive coupling between sensors and readout chips is under
study for the vertex detector at the proposed high-energy CLIC electron
positron collider. The CLICpix Capacitively Coupled Pixel Detector (C3PD) is an
active High-Voltage CMOS sensor, designed to be capacitively coupled to the
CLICpix2 readout chip. The chip is implemented in a commercial nm HV-CMOS
process and contains a matrix of square pixels with m
pitch. First prototypes have been produced with a standard resistivity of
cm for the substrate and tested in standalone mode. The
results show a rise time of ns, charge gain of mV/ke and
e RMS noise for a power consumption of W/pixel. The
main design aspects, as well as standalone measurement results, are presented.Comment: 13 pages, 13 figures, 2 tables. Work carried out in the framework of
the CLICdp collaboratio
Knowledge and behavioural interventions to reduce human health risk from private groundwater systems: A global review and pooled analysis based on development status
Groundwater contamination constitutes a significant health risk for private well users residing in rural areas. As the responsibility to safeguard rural private domestic groundwater typically rests with non-expert homeowners, interventions promoting risk mitigation and awareness represent the most viable means of preventing supply contamination. However, no global review or pooled analyses of these interventions has been undertaken to date. The current study sought to identify and quantify the performance of private well interventions from 1990 to 2018 via a global systematised review and pooled analysis. The PICO (Population-Intervention-Comparison-Outcome) approach was employed for literature identification. Relevant studies were statistically analysed across two quantitative outcome (performance) types, namely knowledge and behaviour, controlling for intervention characteristics and country development status. Mean behavioural and knowledge attainment across interventions was 53% and 48%, respectively, with interventions in economically developed regions exhibiting higher behavioural outcomes (56% vs. 45%) than those in developing regions. Geographically, interventions were located in southern or southeast Asia (n = 23), North America (n = 15), Central America (n = 1) and Africa (n = 1), with none identified in Australia/Oceania, Europe, or South America. Behavioural outcomes were significantly associated with presence of educational/research coordinator (p = 0.023), with these interventions attaining higher levels of efficacy (+74%) than those implemented by other coordinator types. Findings indicate that instructor-led, practical interventions allied with both large- and local-scale awareness-raising campaigns represent an optimum approach for future private well risk interventions. Subsequent adoption of such interventions may lead to increased levels of private well maintenance and provide a point of reference for myriad water and health communication contexts
Combining TCAD and Monte Carlo methods to simulate CMOS pixel sensors with a small collection electrode using the Allpix framework
Combining electrostatic field simulations with Monte Carlo methods enables realistic modeling of the detector response for novel monolithic silicon detectors with strongly non-linear electric fields. Both the precise field description and the inclusion of Landau fluctuations and production of secondary particles in the sensor are crucial ingredients for the understanding and reproduction of detector characteristics.
In this paper, a CMOS pixel sensor with small collection electrode design, implemented in a high-resistivity epitaxial layer, is simulated by integrating a detailed electric field model from finite element TCAD into a Monte Carlo based simulation with the framework. The simulation results are compared to data recorded in test-beam measurements and very good agreement is found for various quantities such as cluster size, spatial resolution and efficiency. Furthermore, the observables are studied as a function of the intra-pixel incidence position to enable a detailed comparison with the detector behavior observed in data.
The validation of such simulations is fundamental for modeling the detector response and for predicting the performance of future prototype designs. Moreover, visualization plots extracted from the charge carrier drift model of the framework can aid in understanding the charge propagation behavior in different regions of the sensor
Edge pixel response studies of edgeless silicon sensor technology for pixellated imaging detectors
Silicon sensor technologies with reduced dead area at the sensor's perimeter are under development at a number of institutes. Several fabrication methods for sensors which are sensitive close to the physical edge of the device are under investigation utilising techniques such as active-edges, passivated edges and current-terminating rings. Such technologies offer the goal of a seamlessly tiled detection surface with minimum dead space between the individual modules. In order to quantify the performance of different geometries and different bulk and implant types, characterisation of several sensors fabricated using active-edge technology were performed at the B16 beam line of the Diamond Light Source. The sensors were fabricated by VTT and bump-bonded to Timepix ROICs. They were 100 and 200 Ό m thick sensors, with the last pixel-to-edge distance of either 50 or 100 Ό m. The sensors were fabricated as either n-on-n or n-on-p type devices. Using 15 keV monochromatic X-rays with a beam spot of 2.5 Ό m, the performance at the outer edge and corners pixels of the sensors was evaluated at three bias voltages. The results indicate a significant change in the charge collection properties between the edge and 5th (up to 275 Ό m) from edge pixel for the 200 Ό m thick n-on-n sensor. The edge pixel performance of the 100 Ό m thick n-on-p sensors is affected only for the last two pixels (up to 110 Ό m) subject to biasing conditions. Imaging characteristics of all sensor types investigated are stable over time and the non-uniformities can be minimised by flat-field corrections. The results from the synchrotron tests combined with lab measurements are presented along with an explanation of the observed effects
Contamination of domestic groundwater systems by verotoxigenic escherichia coli (VTEC), 2003â2019: A global scoping review
peer-reviewedVerocytotoxin-producing E. coli (VTEC) are important agents of diarrhoeal disease in humans globally. As
a noted waterborne disease, emphasis has been given to the study VTEC in surface waters, readily susceptible to microbial contamination. Conversely, the status of VTEC in potable groundwater sources, generally regarded as a âsafeâ drinking-water supply remains largely understudied. As such, this investigation
presents the first scoping review seeking to determine the global prevalence of VTEC in groundwater supply sources intended for human consumption. Twenty-three peer-reviewed studies were identified and
included for data extraction. Groundwater sample and supply detection rates (estimated 0.6 and 1.3%,
respectively) indicate VTEC is infrequently present in domestic groundwater sources. However, where
generic (fecal indicator) E. coli are present, the VTEC to E. coli ratio was found to be 9.9%, representing a latent health concern for groundwater consumers. Geographically, extracted data indicates higher
VTEC detection rates in urban (5.4%) and periâurban (4.9%) environments than in rural areas (0.9%); however, this finding is confounded by the predominance of research studies in lower income regions. Climate trends indicate local environments classified as âtemperateâ (14/554; 2.5%) and âcoldâ (8/392; 2%)
accounted for a majority of supply sources with VTEC present, with similar detection rates encountered
among supplies sampled during periods typically characterized by âhighâ precipitation (15/649; 2.3%). Proposed prevalence figures may find application in preventive risk-based catchment and groundwater quality management including development of Quantitative Microbial Risk Assessments (QMRA). Notwithstanding, to an extent, a large geographical disparity in available investigations, lack of standardized reporting, and bias in source selection, restrict the transferability of research findings. Overall, the mechanisms responsible for VTEC transport and ingress into groundwater supplies remain ambiguous, representing a critical knowledge gap, and denoting a distinctive lack of integration between hydrogeological
and public health research. Key recommendations and guidelines are provided for prospective studies
directed at increasingly integrative and multi-disciplinary research
Contamination of Domestic Groundwater Systems By Verotoxigenic Escherichia Coli (VTEC), 2003â2019: A global scoping review
Verocytotoxin-producing E. coli (VTEC) are important agents of diarrhoeal disease in humans globally. As a noted waterborne disease, emphasis has been given to the study VTEC in surface waters, readily susceptible to microbial contamination. Conversely, the status of VTEC in potable groundwater sources, generally regarded as a âsafeâ drinking-water supply remains largely understudied. As such, this investigation presents the first scoping review seeking to determine the global prevalence of VTEC in groundwater supply sources intended for human consumption. Twenty-three peer-reviewed studies were identified and included for data extraction. Groundwater sample and supply detection rates (estimated 0.6 and 1.3%, respectively) indicate VTEC is infrequently present in domestic groundwater sources. However, where generic (fecal indicator) E. coli are present, the VTEC to E. coli ratio was found to be 9.9%, representing a latent health concern for groundwater consumers. Geographically, extracted data indicates higher VTEC detection rates in urban (5.4%) and periâurban (4.9%) environments than in rural areas (0.9%); however, this finding is confounded by the predominance of research studies in lower income regions. Climate trends indicate local environments classified as âtemperateâ (14/554; 2.5%) and âcoldâ (8/392; 2%) accounted for a majority of supply sources with VTEC present, with similar detection rates encountered among supplies sampled during periods typically characterized by âhighâ precipitation (15/649; 2.3%). Proposed prevalence figures may find application in preventive risk-based catchment and groundwater quality management including development of Quantitative Microbial Risk Assessments (QMRA). Notwithstanding, to an extent, a large geographical disparity in available investigations, lack of standardized reporting, and bias in source selection, restrict the transferability of research findings. Overall, the mechanisms responsible for VTEC transport and ingress into groundwater supplies remain ambiguous, representing a critical knowledge gap, and denoting a distinctive lack of integration between hydrogeological and public health research. Key recommendations and guidelines are provided for prospective studies directed at increasingly integrative and multi-disciplinary research
Performance evaluation of thin active-edge planar sensors for the CLIC vertex detector
Thin planar silicon sensors with a pitch of 55ÎŒm, active edge and various guard-ring layouts are investigated,using two-dimensional finite-element T-CAD simulations. The simulation results have been compared toexperimental data, and an overall good agreement is observed. It is demonstrated that the 50ÎŒm thick active-edge planar silicon sensors with floating guard-ring or without guard-ring can be operated fully efficiently upto the physical edge of the sensor. The simulation findings are used to identify suitable sensor designs forapplication in the high-precision vertex detector of the future CLIC linear ee collider
Time resolution studies of Timepix3 assemblies with thin silicon pixel sensors
Timepix3 is a multi-purpose readout ASIC for hybrid pixel detectors. It can measure time and amplitude simultaneously by employing time-of-arrival (ToA) and time-over-threshold (ToT) techniques. Both methods are systematically affected by timewalk. In this paper, a method for pixel-by-pixel calibration of the time response is presented. Assemblies of Timepix3 ASICs bump-bonded to thin planar silicon pixel sensors with thicknesses of 50 Ό m, 100 Ό m and 150 Ό m are calibrated and characterised in particle beams. For minimum ionising particles, time resolutions down to 0.72 ± 0.04 ns are achieved
Les temps de la consultation du comitĂ© dâentreprise
The DD4HEP detector description toolkit offers a flexible and easy-to-use solution for the consistent and complete description of particle physics detectors in a single system. The sub-component DDREC provides a dedicated interface to the detector geometry as needed for event reconstruction. With DDREC there is no need to define an additional, separate reconstruction geometry as is often done in HEP, but one can transparently extend the existing detailed simulation model to be also used for the reconstruction. Based on the extension mechanism of DD4HEP, DDREC allows one to attach user defined data structures to detector elements at all levels of the geometry hierarchy. These data structures define a high level view onto the detectors describing their physical properties, such as measurement layers, point resolutions, and cell sizes. For the purpose of charged particle track reconstruction, dedicated surface objects can be attached to every volume in the detector geometry. These surfaces provide the measurement directions, local-to-global coordinate transformations, and material properties. The material properties, essential for the correct treatment of multiple scattering and energy loss effects in charged particle reconstruction, are automatically averaged from the detailed geometry model along the normal of the surface. Additionally, a generic interface allows the user to query material properties at any given point or between any two points in the detector's world volume. In this paper we will present DDREC and how it is used together with the linear collider tracking software and the particle-flow package PANDORAPFA for full event reconstruction of the ILC detector concepts ILD and SiD, and of CLICdp. This flexible tool chain is also well suited for other future accelerator projects such as FCC and CEPC
- âŠ