32 research outputs found

    iStent as a Solo Procedure for Glaucoma Patients: A Systematic Review and Meta-Analysis

    Get PDF
    BACKGROUND: Glaucoma is a leading cause of irreversible blindness. It is firmly entrenched in the traditional treatment paradigm to start with pharmacotherapy. However, pharmacotherapy is not benign and has been well documented to have a number of significant challenges. Minimally invasive glaucoma surgery (MIGS) that targets the outflow pathway with minimal to no scleral dissection has resulted in the need to reconsider the glaucoma treatment paradigm. PURPOSE: To perform a systematic review and meta-analysis to evaluate and quantify the effect on post-operative intraocular pressure (IOP) and number of topical glaucoma medications, in patients receiving the iStent MIGS device as the solo procedure without concurrent cataract surgery. METHODS: A systematic review was conducted by searching various databases between January 1, 2000, and June 30, 2014. Studies reporting up to a maximum follow-up period of 24 months were retrieved and screened using the EPPI-Reviewer 4 gateway. Percentage reduction in IOP (IOPR%), and mean reduction in topical glaucoma medications after surgery were computed. Meta-analysis was performed using STATA v. 13.0. The standardized mean difference (SMD) was calculated as the effect size for continuous scale outcomes. Heterogeneity was determined using the I2 statistics, Z-value, and χ2 statistics. Fixed-effect and random-effect models were developed based on heterogeneity. Sub-group analysis was performed based on the number of iStents implanted and the follow-up period. The outcome measures were changes in the IOP and number of glaucoma medications. RESULTS: The search strategy identified 105 records from published literature and 9 records from the grey literature. Five studies with 248 subjects were included for quantitative synthesis. A 22% IOP reduction (IOPR%) from baseline occurred at 18-months after one iStent implant, 30% at 6-months after two iStents implantations, and 40% at 6-months after implantation of three iStents. A mean reduction of 1.2 bottles per patient of topical glaucoma medications occurred at 18-months after one iStent implant, 1.45 bottles per patient at 6-months after two iStents, and one bottle of medication per patient was reduced at 6-months following placement of three iStents implants. Meta-analysis results showed a significant reduction in the IOP after one iStent (SMD = -1.68, 95% CI: [-2.7, -0.61]), two iStents (SMD = -1.88, 95% CI: [-2.2, -1.56]), and three iStents (SMD = -2, 95% CI: [-2.62, -1.38]) implantation. Results showed a significant drop in the topical glaucoma medications after one iStent (SMD = -2.11, CI: [-3.95, -0.27]), two iStent (SMD = -1.88, CI: [-2.20, -1.56]), and three iStents (SMD = -2.00, CI: [-2.62, -1.38]) implantation. The maximum reduction in IOP occurred at 12-months (SMD = -2.21, CI: [-2.53, -1.88]) and a significant reduction in post-operative topical glaucoma medications occurred even after 18-months of iStent implantation (SMD = -0.71, CI: [-1.15, -0.26]). CONCLUSION: iStent implantation as a solo procedure without concurrent cataract extraction does lower IOP, and reduces the dependency on glaucoma medications. This effect seems to last at least 18 months

    Ocular Pathology Relevant to Glaucoma in a Gja1(Jrt) Mouse Model of Human Oculodentodigital Dysplasia

    Get PDF
    PURPOSE. Oculodentodigital dysplasia (ODDD) is a human disorder caused by mutations in the gap junction alpha 1 (GJA1) gene encoding the connexin43 (Cx43) gap junction protein. Causal links between GJA1 mutations and glaucoma are not understood. The purpose in this study was to examine the ocular phenotype for Gja1(Jrt/+) mice harboring a Cx43 G60S mutation. METHODS. In young Gja1(Jrt/+) mice, Cx43 abundance was assessed with a Western blot, and Cx43 localization was visualized using immunohistochemistry and confocal microscopy. Intraocular pressure (IOP) was measured by rebound tonometry, and eye anatomy was imaged using ocular coherence tomography (OCT). Hematoxylin and eosin (H&E)-stained eye sections were examined for ocular histopathology related to the development of glaucoma. RESULTS. Decreased Cx43 protein levels were evident in whole eyes from Gja1(Jrt/+) mice compared with those of wild-type mice at postnatal day 1 (P = 0.005). Cx43 immunofluorescence in ciliary bodies of Gja1(Jrt/+) mice was diffuse and intracellular, unlike the gap junction plaques prevalent in wildtype mice. IOP in Gja1(Jrt/+) mice changed during postnatal development, with significantly lower IOP at 21 weeks of age in comparison to the IOP of wild-type eyes. Microphthalmia, enophthalmia, anterior angle closure, and reduced pupil diameter were observed in Gja1(Jrt/+) mice at all ages examined. Ocular histology showed prominent separations between the pigmented and nonpigmented ciliary epithelium of Gja1(Jrt/+) mice, split irides, and alterations in the number and distribution of nuclei in the retina. CONCLUSIONS. Detailed phenotyping of Gja1(Jrt/+) eyes offers a framework for elucidating human ODDD ocular disease mechanisms and evaluating new treatments designed to protect ocular synaptic network integrity

    Comparison of Newly Diagnosed Ocular Hypertension and Open-Angle Glaucoma: Ocular Variables, Risk Factors, and Disease Severity

    Get PDF
    Purpose. To describe the distribution of ocular variables, risk factors, and disease severity in newly diagnosed ocular hypertension (OH) or open-angle glaucoma (OAG). Methods. Eligible subjects underwent a complete history and examination. Adjusted odds ratios (ORs) and 95% confidence intervals (CIs) obtained from multiple logistic regression models were used to compare OAG to OH and advanced to early/moderate OAG. Results. 405 subjects were enrolled: 292 (72.1%) with OAG and 113 (27.9%) with OH. 51.7% had early, 27.1% moderate, and 20.9% advanced OAG. The OR for OAG versus OH was 8.19 (P < 0.0001) for disc notch, 5.36 (P < 0.0001) for abnormal visual field, 1.45 (P = 0.001) for worsening mean deviation, 1.91 (P < 0.0001) for increased cupping, 1.03 for increased age (P = 0.030), and 0.36 (P = 0.010) for smoking. Conclusions. Increased age was a risk for OAG, and smoking decreased the risk of OAG compared to OH. Almost half of the OAG subjects had moderate/advanced disease at diagnosis

    Tissue Transglutaminase Is a Negative Regulator of Monomeric Lacritin Bioactivity

    Get PDF
    PURPOSE. Molar accounting of bioactive fluids can expose new regulatory mechanisms in the growing proteomic focus on epithelial biology. Essential for the viability of the surface epithelium of the eye and for normal vision is the thin, but protein-rich, tear film in which the small tear glycoprotein lacritin appears to play a prominent prosecretory, cytoprotective, and mitogenic role. Although optimal bioactive levels in cell culture are 1 to 10 nM over a biphasic dose optimum, ELISA suggests a sustained tear lacritin concentration in the midmicromolar range in healthy adults. Here we identify a reconciling mechanism. METHODS. Monoclonal anti-lacritin 1F5 antibody was generated, and applied together with a new anti-C-terminal polyclonal antibody to tear and tissue Western blotting. In vitro tissue transglutaminase (Tgm2) cross-linking was monitored and characterized by mass spectrometry. RESULTS. Blotting for lacritin in human tears or saliva surprisingly detected immunoreactive material with a higher molecular weight and prominence equal or exceeding the~23 to 25 kDa band of monomeric glycosylated lacritin. Exogenous Tgm2 initiated lacritin cross-linking within 1 minute and was complete by 90 minutes-even with as little as 0.1 nM lacritin, and involved the donors lysine 82 and 85 and the acceptor glutamine 106 in the syndecan-1 binding domain. Lacritin spiked into lacritin-depleted tears formed multimers, in keeping with~0.6 lM TGM2 in tears. Cross-linking was absent when Tgm2 was inactive, and cross-linked lacritin, unlike recombinant monomer, bound syndecan-1 poorly. Enhanced TGM2 expression correlates with reduced cell viability, caspase activation, TNF receptor clustering, 7 and mitochondrial dysfunction 8 associated with hyperosmolar stress in dry eye. 14 Could TGM2 in tears regulate ocular surface biology? Lacritin is a 12.3 kDa tear prosecretory mitogen 15 with glutamine and lysine residues suitable for TGM2 catalyzed cross-linking. Lacritin promotes corneal epithelial cell survival (Zimmerman K, et al. IOVS 2012;53:ARVO E-Abstract 4231) and proliferation

    When Is Evidence Enough Evidence? A Systematic Review and Meta-Analysis of the Trabectome as a Solo Procedure in Patients with Primary Open-Angle Glaucoma

    No full text
    The purpose of this systematic review and meta-analysis was to examine the availability of evidence for one of the earliest available minimally invasive glaucoma surgery (MIGS) procedures, the Trabectome. Various databases were searched up to December 20, 2016, for any published studies assessing the use of the Trabectome as a solo procedure in patients with primary open-angle glaucoma (POAG). The standardized mean differences (SMD) were calculated for the change in intraocular pressure (IOP) and number of glaucoma mediations used at 1-month, 6-month, and 12-month follow-up. After screening, three studies and one abstract with analyzable data were included. The meta-analysis showed statistically significant reductions in IOP and number of glaucoma medications used at all time points. Though the Trabectome as a solo procedure appears to lower IOP and reduces the number of glaucoma medications, more high-quality studies are required to make definitive conclusions. The difficulty of obtaining evidence may be one of the many obstacles that limit a full understanding of the potential safety and/or efficacy benefits compared to standard treatments. The time has come for a thoughtful and integrated approach with stakeholders to determine optimal access to care strategies for our patients

    Assessing the Methodological Quality of Glaucoma Clinical Practice Guidelines and their Recommendations on Microinvasive Glaucoma Surgery: A Systematic Review

    No full text
    Introduction: Clinical practice guidelines (CPG) are regarded by many as critical communications providing guidance within specific medical fields. Over a decade ago, the first microinvasive glaucoma surgical procedures (MIGS) were introduced. Since then, a number of these novel intraocular pressure (IOP) controlling surgical options have been approved worldwide. Governing bodies and healthcare administration often utilize CPGs when considering funding for newer technologies. This highlights the importance of well-written, accurate and up-to-date CPGs in the rapidly evolving field of MIGS. If CPGs are unable to fill this role, their use in treatment decision making is doing a disservice to patients, who will be denied currently available and potentially superior care. To determine the overall value of a CPG, the methodological quality with which it was developed, in addition to the current relevance and appropriateness of its recommendations, should be evaluated. The objective of the present study was to assess the methodological quality of currently available international glaucoma CPGs, as well as their coverage of MIGS as a surrogate marker of relevance and appropriateness to policy makers and ophthalmologists alike. Materials and Methods: To identify potentially relevant CPGs, a predefined search strategy was employed to search the following databases: Medline, EMBASE, BIOSIS and Web of Science. All CPGs related to adult glaucoma and published in English were included. CPG methodological quality was assessed by three individuals using the Appraisal of Guidelines for Research and Evaluation II (AGREE II) tool. Studies were then assessed for coverage of MIGS devices and procedures. Results: Search strategy and subsequent screening identified 11 CPGs for analysis. Eight were of high quality according to the AGREE II criteria. Three included basic information on MIGS, but none provided specific recommendations regarding their indications or which patient populations would benefit most. Conclusion: Many international glaucoma CPGs are of high methodological quality. However, coverage of MIGS is sparse, nonspecific and in many instances, absent. This causes CPGs to be a suboptimal source in guiding physicians and health policy makers in areas characterized by novel and/or rapidly evolving technologies. Mechanisms to incorporate updated evidence in CPGs would have to be considered before they can be used as a source of contemporary clinical decision-making

    A randomized clinical trial of selective laser trabeculoplasty versus argon laser trabeculoplasty in patients with pseudoexfoliation

    No full text
    Purpose: To evaluate the efficacy of selective laser trabeculoplasty (SLT) versus argon laser trabeculoplasty (ALT) in lowering the intraocular pressure (IOP) in patients with open-angle glaucoma or ocular hypertension secondary to pseudoexfoliation.Design: Multicentered randomized clinical trial.Participants: A total of 76 eyes from 60 patients with pseudoexfoliation and uncontrolled IOP were recruited from 5 Canadian academic institutions. Patients with prior laser trabeculoplasty, ocular surgery within 6 months, previous glaucoma surgery, an advanced visual field defect, current steroid use, and monocular patients were excluded.Methods: Eyes were randomized to receive either 180-degree SLT or 180-degree ALT by a nonblocked randomization schedule stratified by center.Main outcome measurement: The primary outcome was the change in IOP at 6 months versus baseline and secondary outcomes included change in number of glaucoma medications after laser. Baseline variables included age, sex, angle grade, angle pigmentation, and number of glaucoma medications.Results: Of the 76 eyes, 45 eyes received SLT and 31 eyes received ALT. The overall age was 72.9 years (65% females). The baseline IOPs in the SLT and ALT groups were 23.1 and 25.2 mm Hg, respectively (P=0.03). The IOP reduction 6 months after SLT was -6.8 mm Hg and post-ALT was -7.7 mm Hg (P\u3e0.05). The SLT group had reduced glaucoma medications by 0.16 medications at 6 months and the ALT group had no decrease in medications over the same time period (P=0.59). There were no postlaser IOP spikes in either group.Discussion: ALT and SLT are equivalent in lowering IOP at 6 months posttreatment in patients with PXF

    iStent with Phacoemulsification versus Phacoemulsification Alone for Patients with Glaucoma and Cataract: A Meta-Analysis.

    No full text
    Minimally invasive glaucoma surgeries (MIGS) have attracted significant attention, as they have been reported to lower intra-ocular pressure (IOP) and have an excellent safety profile. The iStent is an example of a minimally invasive glaucoma device that has received particular attention due to its early and wide spread utilization. There is a growing body of evidence supporting its use at the time of phacoemulsification to help lower IOP. However, it is still not clear how much of the IOP lowering effect can be attributed to the iStent, the crystalline lens extraction or both when inserted concurrently at the time of phacoemulsification. This has been an important issue in understanding its potential role in the glaucoma management paradigm.To conduct a systematic review and meta-analysis comparing the IOP lowering effect of iStent insertion at the time of phacoemulsification versus phacoemulsification alone for patients with glaucoma and cataracts.A systematic review was conducted utilizing various databases. Studies examining the IOP lowering effect of iStent insertion in combination with phacoemulsification, as well as studies examining the IOP lowering effect of phacoemulsification alone were included. Thirty-seven studies, reporting on 2495 patients, met the inclusion criteria. The percentage reduction in IOP (IOPR%) and mean reduction in topical glaucoma medications after surgery were determined. The standardized mean difference (SMD) was computed as a measure of the treatment effect for continuous outcomes taking into account heterogeneity. Fixed-effect and random-effect models were applied.A 4% IOP reduction (IOPR%) from baseline occurred following phacoemulsification as a solo procedure compared to 9% following an iStent implant with phacoemulsification, and 27% following 2 iStents implants with phacoemulsification. Compared with cataract extraction alone, iStent with phacoemulsification resulted in significant reduction in the post-operative IOP (IOPR%) (SMD = -0.46, 95% CI: [-0.87, -0.06]). A weighted mean reduction in the number of glaucoma medications per patient was 1.01 following phacoemulsification alone compared to 1.33 after one iStent implant with phacoemulsification, and 1.1 after 2 iStent implants with phacoemulsification. Compared to cataract extraction alone, iStent with cataract extraction showed a significant decrease in the number of glaucoma medications (SMD = -0.65, 95% CI: [-1.18, -0.12]). Funnel plots suggested the absence of publication bias.Both iStent implantation with concurrent phacoemulsification and phacoemulsification alone result in a significant decrease in IOP and topical glaucoma medications. In terms of both reductions, iStent with phacoemulsification significantly outperforms phacoemulsification alone
    corecore