277 research outputs found

    Robust helical path separation for thickness mapping of pipes by guided wave tomography

    Get PDF

    Improved Scattering Models for Guided Wave Tomography

    Get PDF
    Water collecting at pipe supports will accelerate corrosion, reducing the pipe life at a very difficult-to-inspect location. A traditional approach would require the pipe to be emptied, lifted and an ultrasonic thickness gauge be scanned across the surface. Guided wave tomography could potentially address these problems: by sending waves from an array on one side of the support through to a set of receivers on the other side, an image of the thickness can be produced, which is typically achieved by exploiting the dispersive nature of guided waves causing their speed to change depending on the thickness. However, this assumption results in a resolution limit of around 2 wavelengths (roughly 8 times wall thickness at a typical operating point), which is often too low for tomography to be a practical solution. To go beyond this, better models of guided wave scattering are needed. This talk will discuss approaches to address the limitations through more realistic scattering assumptions

    Guided wave tomography with an improved scattering model

    Get PDF
    Producing accurate thickness maps of corrosion damage is of great importance for assessing life in the petrochemical industry. Guided wave tomography provides a solution for this, by sending guided waves through the region of interest, then using tomographic imaging techniques to reconstruct the thickness map, importantly eliminating the need to take measurements at all points across the surface. However, to achieve accurate maps, the imaging algorithm must account for the way in which the guided waves interact with corrosion defects, and the complex scattering which occurs. Traditional approaches have exploited the dispersive nature of guided waves: a velocity map is produced from a dataset, then converted to thickness using the dispersion relationship. However, these relationships are derived for plates of constant thickness, which is not the case in the majority of defects, causing significant inaccuracies to exist in the images. This paper develops a more sophisticated inversion solution which accounts for the full-guided wave scattering, enabling more accurate images with resolution better than a wavelength, compared with two wavelengths previously. This is demonstrated with simulated and experimental data. The speed and stability of the algorithm in the presence of random noise and systematic errors is also demonstrated

    Virtual Extended-Range Tomography (VERT): Contact-free realistic ultrasonic bone imaging

    Full text link
    Ultrasound tomography generally struggles to reconstruct high-contrast and/or extended-range problems. A prime example is site-specific in-vivo bone imaging, crucial for accurately assessing the risk of life-threatening fractures, which are preventable given accurate diagnosis and treatment. In this type of problem, two main obstacles arise: (a) an external region prohibits access to the region of interest (ROI), and (b) high contrast exists between the two regions. These challenges impede existing algorithms -- including bent-ray tomography (BRT), known for its robustness, speed, and reasonable short-range resolution. We propose Virtual Extended-Range Tomography (VERT), which tackles these challenges through (a) placement of virtual transducers directly on the ROI, facilitating (b) rapid initialisation before BRT inversion. In-silico validation against BRT with and without a-priori information shows superior resolution and robustness -- while maintaining or even improving speed. These improvements are drastic where the external region is much larger than the ROI. Additional validation against the practically impossible -- BRT directly on the ROI -- demonstrates that VERT is approaching the resolution limit. The capability to solve high-contrast extended-range tomography problems without prior knowledge about the ROI's interior has many implications. VERT has the potential to unlock site-specific in-vivo bone imaging for assessing fracture risk, potentially saving millions of lives globally. In other applications, VERT may replace classical BRT to yield improvements in resolution, robustness and speed -- especially where the ROI does not cover the entire imaging array. For even higher resolution, VERT offers a reliable starting background to complement algorithms with less robustness and high computational costs.Comment: 14 pages, 9 figures including graphical abstract. Submitted to IEEE T-UFF

    Limited View X-Ray CT for Turbine Blade Characterization

    Get PDF
    Turbine blades routinely contain complex and irregular internal structures making them difficult to inspect with most NDE techniques. X-ray CT provides a powerful inspection tool, enabling 2/3D images of the turbine blade to be produced. However, standard X-ray CT methods require thousands of projections, each regularly distributed evenly through 360° to produce an accurate image. The large number of projections and the regularity of sampling can result in lengthy data acquisition times and can lead to bottlenecks in manufacturing throughput. To alleviate these bottlenecks in throughput companies may be forced to purchase additional X-ray CT capability at great cost. In recent years there has been a drive by the medical industry to reduce patient X-ray exposure by limiting the number of projections whilst maintaining image quality in CT applications. Spurred by the ever increasing power of computers and the advents of graphics card processors a variety of limited view tomographic techniques capable of generating high quality images with less data have been developed. Central to these new algorithms is the principle of compressed sensing whereby an understanding of the signal sparsity is exploited to produce accurate reconstructions of the signal of interest with fewer samples than those required by the Shannon-Nyqist theorem. We present a survey of limited view algorithms for x-ray CT of a turbine blade with the aim of producing accurate internal structure estimates using minimal data

    The application of the Factorization Method to the subsurface imaging of surfacebreaking cracks

    Get PDF
    A common location for cracks to appear is at the surface of a component; at the near surface, many nondestructive evaluation techniques are available to inspect for these, but at the far surface this is much more challenging. Ultrasonic imaging is proposed to enable far surface defect detection, location, and characterization. One specific challenge here is the presence of a strong reflection from the backwall, which can often mask the relatively small response from a defect. In this paper, the factorization method (FM) is explored for the application of subsurface imaging of the surface-breaking cracks. In this application, the component has two parallel surfaces, the crack is initiated from the far side and the phased array is attached on the near side. Ideally, the pure scattered field from a defect is needed for the correct estimation of the scatterer through the FM algorithm. However, the presence of the backwall will introduce a strong specular reflection into the measured data which should be removed before applying the FM algorithm. A novel subtraction method was developed to remove the backwall reflection. The performance of the FM algorithm and this subtraction method were tested with the simulated and experimental data. The experimental results showed a good consistency with the simulated results. It is shown that the FM algorithm can generate high-quality images to provide a good detection of the crack and an accurate sizing of the crack length. The subtraction method was able to provide a good backwall reflection removal in the case of small cracks (1-3 wavelengths)
    corecore