4,884 research outputs found
Fabrication of porous matrix membrane (PMM) using metal-organic framework as green template for water treatment
published_or_final_versio
Recommended from our members
Numerical studies on dynamic behavior of tubular T-joint subjected to impact loading
Joints play an important role in resisting impact loading in Tubular structures. In this paper, a finite element model validated by experimental results is developed to numerically study the failure modes and energy dissipation mechanism of tubular T-joint impacted by a drop hammer with the initial velocity of 7–10 m/s. The resistant mechanism is investigated based on the dynamic responses of the joints under impact loading. Strain, displacement and the failure modes of the T-joints are also predicted. Global and local deformations of the tubular joints are distinguished using an equal area axis method, which helps to discover the failure mechanism of the joints. Using the yield line theory, an equivalent impact force estimation method is also proposed based on the impact load versus displacement relationship. The numerical analysis and the simplified method provide a basis for impact resistance evaluation and progressive collapse mitigation of steel tubular structures in design practice in the future
Radiation therapy combined with intracerebral administration of carboplatin for the treatment of brain tumors
Background: In this study we determined if treatment combining radiation therapy (RT) with intracerebral (i.c.) administration of carboplatin to F98 glioma bearing rats could improve survival over that previously reported by us with a 15 Gy dose (5 Gy × 3) of 6 MV photons.Methods: First, in order to reduce tumor interstitial pressure, a biodistribution study was carried out to determine if pretreatment with dexamethasone alone or in combination with mannitol and furosemide (DMF) would increase carboplatin uptake following convection enhanced delivery (CED). Next, therapy studies were carried out in rats that had received carboplatin either by CED over 30 min (20 μg) or by Alzet pumps over 7 d (84 μg), followed by RT using a LINAC to deliver either 20 Gy (5 Gy × 4) or 15 Gy (7.5 Gy × 2) dose at 6 or 24 hrs after drug administration. Finally, a study was carried out to determine if efficacy could be improved by decreasing the time interval between drug administration and RT.Results: Tumor carboplatin values for D and DMF-treated rats were 9.4 ±4.4 and 12.4 ±3.2 μg/g, respectively, which were not significantly different (P = 0.14). The best survival data were obtained by combining pump delivery with 5 Gy × 4 of X-irradiation with a mean survival time (MST) of 107.7 d and a 43% cure rate vs. 83.6 d with CED vs. 30-35 d for RT alone and 24.6 d for untreated controls. Treatment-related mortality was observed when RT was initiated 6 h after CED of carboplatin and RT was started 7 d after tumor implantation. Dividing carboplatin into two 10 μg doses and RT into two 7.5 Gy fractions, administered 24 hrs later, yielded survival data (MST 82.1 d with a 25% cure rate) equivalent to that previously reported with 5 Gy × 3 and 20 μg of carboplatin.Conclusions: Although the best survival data were obtained by pump delivery, CED was highly effective in combination with 20 Gy, or as previously reported, 15 Gy, and the latter would be preferable since it would produce less late tissue effects.peer-reviewe
Metamaterial slab as a lens, a cloak or something in between
We show that a metamaterial slab with arbitrary values of epsilon and mu
behaves as a cloak at a finite frequency for a small object located
sufficiently close to it due to the suppression of the object's optical
excitations by enhanced reflections. Reflections due to propagating components
can partially suppress the excitation while evanescent components can cloak the
object completely. In particular, a Veselago slab with epsilon = mu = -1 + i
delta, as well as a class of anisotropic negative refractive index slabs, can
completely cloak the small object placed within a finite distance from the slab
when delta -> 0.Comment: 28 pages, 4 figures, including a paper and its auxiliary materia
Lepton flavor violation two-body decays of quarkoniums
In this paper we firstly study various model-independent bounds on lepton
flavor violation (LFV) in processes of , and
two-body decays, then calculate their branch ratios % By using the constraints
from other ways, we obtain %the indirect bounds of in models of the leptoquark, violating
MSSM and topcolor assisted technicolor(TC2) models.Comment: 14 pages, 4 figures, submitted to PR
Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
We report a prospective study of the liner-metal interfaces of modular uncemented acetabular components as sources of debris. We collected the pseudomembrane from the screw-cup junction and the empty screw holes of the metal backing of 19 acetabula after an average implantation of 22 months. Associated osteolytic lesions were separately collected in two cases. The back surfaces of the liners and the screws were examined for damage, and some liners were scanned by electron microscopy. The tissues were studied histologically and by atomic absorption spectrophotometry to measure titanium content. The pseudomembrane from the screw-cup junction contained polyethylene debris in seven specimens and metal debris in ten. The material from empty screw holes was necrotic tissue or dense fibroconnective tissue with a proliferative histiocytic infiltrate and foreign-body giant-cell reaction. It contained polyethylene debris in 14 cases and metal in five. The two acetabular osteolytic lesions also showed a foreign-body giant-cell reaction to particulate debris. The average titanium levels in pseudomembranes from the screw-cup junction and the empty screw holes were 959 micrograms/g (48 to 11,900) and 74 micrograms/g (0.72 to 331) respectively. The tissue from the two lytic lesions showed average titanium levels of 139 and 147 micrograms/g respectively. The back surfaces of the PE liners showed surface deformation, burnishing, and embedded metal debris. All 30 retrieved screws demonstrated fretting at the base of the head and on the proximal shaft. Non-articular modular junctions create new interfaces for the generation of particulate debris, which may cause granulomatous reaction
- …