6 research outputs found

    Effect of Axial Load on the Flexural Properties of an Elastomeric Total Disc Replacement

    Get PDF
    Study Design. Twelve Cadisc-L devices were subjected to flexion (0°–6°) and extension (0° to -3°) motions at compressive loads between 500 N and 2000 N at a flexural rate between 0.25°/s and 3.0°/s.\ud \ud Objective. To quantify the change in flexural properties of the Cadisc-L (elastomeric device), when subjected to increasing magnitudes of axial load and at different flexural rates.\ud \ud Summary of Background Data. The design of motion preservation devices, used to replace degenerated intervertebral discs, is commonly based on a low-friction, ball-and-socket-articulating joint. Recently, elastomeric implants have been developed that attempt to provide mechanical and motion properties that resemble those of the natural disc more closely.\ud \ud Methods. Twelve Cadisc-L devices (MC-10 mm-9° and MC-10 mm-12° size) were supplied by Ranier Technology Ltd (Cambridge, United Kingdom). The devices were hydrated and tested using a Bose spinal disc-testing machine (Bose Corporation, ElectroForce Systems Group, Eden Prairie, MN) in Ringer's solution at 37°C. A static load of 500 N was applied to a device and it was then subjected to motions of 0° to 6° to 0° (flexion) and 0° to -3° to 0° (extension) at a flexural rate of 0.25°/s, 0.5°/s, 1.0°/s, 1.5°/s, 2.0°/s, and 3.0°/s. Tests were repeated at 1000 N, 1500 N, and 2000 N.\ud \ud Results. Regression analyses showed a significant (R2R^2 > 0.99, ρ\rho< 0.05) linear increase in bending moment and flexural stiffness with flexion and extension angles (at 1000 N and higher loads)—a significant (R2R^2> 0.994, ρ\rho< 0.05) linear decrease in flexural stiffness in flexion and extension as flexural rate increased.\ud \ud Conclusion. The bending moment of the Cadisc-L increased linearly with flexion and extension angles at 1000 N and higher loads. Flexural stiffness increased with compressive load but decreased with flexural rate.\ud \u

    Biotransformation of Silver Released from Nanoparticle Coated Titanium Implants Revealed in Regenerating Bone

    Get PDF
    Antimicrobial silver nanoparticle coatings have attracted interest for reducing prosthetic joint infection. However, few studies report in vivo investigations of the biotransformation of silver nanoparticles within the regenerating tissue and its impact on bone formation. We present a longitudinal investigation of the osseointegration of silver nanoparticle-coated additive manufactured titanium implants in rat tibial defects. Correlative imaging at different time points using nanoscale secondary ion mass spectrometry, transmission electron microscopy (TEM), histomorphometry, and 3D X-ray microcomputed tomography provided quantitative insight from the nano- to macroscales. The quality and quantity of newly formed bone is comparable between the uncoated and silver coated implants. The newly formed bone demonstrates a trabecular morphology with bone being located at the implant surface, and at a distance, at two weeks. Nanoscale elemental mapping of the bone−implant interface showed that silver was present primarily in the osseous tissue and colocalized with sulfur. TEM revealed silver sulfide nanoparticles in the newly regenerated bone, presenting strong evidence that the previously in vitro observed biotransformation of silver to silver sulfide occurs in vivo
    corecore