13 research outputs found

    A multicenter, prospective, single-arm clinical investigation of a modified staged treatment algorithm using the AeriSeal system:The STAGE trial

    Get PDF
    Introduction: Treatment with AeriSeal is an alternate treatment option to achieve lung volume reduction in patients with severe COPD and emphysema who are not eligible for valve treatment. This study aimed to assess the safety and mode of action of a modified staged treatment algorithm with a staged treatment with lower dose of AeriSeal. Methods: We performed a prospective, multicenter feasibility study. AeriSeal was administered during two sequential bronchoscopies: 2 subsegments of a lobe treated with two 5 mL doses, followed by two 10 mL doses in a contralateral lobe after 6 weeks. Results: A total of 14 patients (36% male, mean FEV1 28.4% ± 6.7% of predicted) were enrolled. Ten patients completed both treatments, four were treated unilaterally. AeriSeal treatment resulted in significant TLVR (median 220.5 mL) at 3 months follow up. There were no significant changes from baseline at 12 months in lung function, exercise capacity and quality of life. During the 3-month post-treatment period, respiratory SAEs included 5 COPD exacerbations in 4 (28.6%) subjects, post-treatment acute inflammatory response (PAIR) in 2 (14.3%) subjects, and 1 respiratory failure event in 1 (7.1%) subject. Conclusion: The staged and lower dosed administration of AeriSeal does not impact the overall safety profile in terms of reducing the type and frequency of respiratory SAEs previously reported for a single-stage treatment. A larger volume of AeriSeal than used in this study may be necessary to provide meaningful clinical benefits

    Endobronchial Valve (Zephyr) Treatment in Homogeneous Emphysema:One-Year Results from the IMPACT Randomized Clinical Trial

    Get PDF
    RATIONALE: The long-term safety and effectiveness of bronchoscopic lung volume reduction with Zephyr endobronchial valves in subjects with severe homogeneous emphysema with little to no collateral ventilation beyond 3 months have yet to be established. METHODS: Ninety-three subjects were randomized to either bronchoscopic lung volume reduction with Zephyr valves or standard of care (SoC) (1:1). Zephyr valve subjects were assessed at 3, 6, and 12 months. SoC subjects were assessed at 3 and 6 months; they were then offered crossover to Zephyr valve treatment. RESULTS: The mean group difference (Zephyr valve − SoC) for change in FEV1 from baseline to 6 months was 16.3 ± 22.1% (mean ± SD; p < 0.001). Secondary outcomes showed the mean between-group difference for the six-minute walk distance of +28.3 ± 55.3 m (p = 0.016); St. George's Respiratory Questionnaire, −7.51 ± 9.56 points (p < 0.001); modified Medical Research Council, −0.42 ± 0.81 points (p = 0.019); BODE index, −0.85 ± 1.39 points (p = 0.006); and residual volume of −430 ± 830 mL (p = 0.011) in favor of the Zephyr valve group. At 6 months, there were significantly more responders based on the minimal clinically important difference for these same measures in the Zephyr valve versus the SoC group. The clinical benefits were persistent at 12 months. The percentage of subjects with respiratory serious adverse events was higher in the Zephyr valve group compared to SoC during the first 30 days post-procedure but not statistically different for the Zephyr valve and SoC groups from 31 days to 6 months, and stable in the Zephyr valve group out to 12 months. There were 2 deaths in the SoC group in the 31-day to 6-month period and none in the Zephyr valve group out to 12 months. CONCLUSIONS: Bronchoscopic lung volume reduction with Zephyr valves in subjects with severe homogeneous emphysema and little to no collateral ventilation provides clinically meaningful change from baseline in lung function, quality of life, exercise capacity, dyspnea, and the BODE index at 6 months, with benefits maintained out to 12 months

    An Integrative Approach of the Fissure Completeness Score and Chartis Assessment in Endobronchial Valve Treatment for Emphysema

    Get PDF
    Purpose: Lung volume reduction using one-way endobronchial valves is a bronchoscopic treatment for patients with severe emphysema without collateral ventilation between the treatment target lobe and the ipsilateral lobe(s). CT-scan fissure analysis is often used as a surrogate to predict the absence of collateral ventilation. We aimed to evaluate the predictive value of the fissure completeness score (FCS) compared to the functional Chartis measurement of collateral ventilation and to provide cut-off values of the FCS in patient selection. Patients and Methods: Multicenter study in patients eligible for treatment with one-way valves. The FCS was calculated by quantitative CT analysis (Thirona, the Netherlands) and compared to status of interlobar collateral ventilation measured with Chartis system (PulmonX, USA). Thresholds were calculated for the predictive values of the presence of collateral ventilation. Results: An FCS >95% of the left major fissure had a positive predictive value (PPV) of 91%, with 1 in 11 fissures demonstrating collateral ventilation with Chartis measurement, whereas an FCS of ≀80% had a negative predictive value (NPV) of 100% for the presence of collateral ventilation. For the right major fissure, the NPV was 100% for an FCS ≀90%, but 69.7% for the right upper lobe fissure. Conclusion: Quantitative CT analysis is recommended in all patients evaluated for endo-bronchial valves. Patients with incomplete fissures (left major fissure: FCS 95%

    A Multicenter Randomized Controlled Trial of Zephyr Endobronchial Valve Treatment in Heterogeneous Emphysema (TRANSFORM)

    Get PDF
    Rationale: Single-center randomized controlled trials of the Zephyr endobronchial valve (EBV) treatment have demonstrated benefit in severe heterogeneous emphysema. This is the first multicenter study evaluating this treatment approach. Objectives: To evaluate the efficacy and safety of Zephyr EBVs in patients with heterogeneous emphysema and absence of collateral ventilation. Methods: This was a prospective, multicenter 2:1 randomized controlled trial of EBVs plus standard of care or standard of care alone (SoC). Primary outcome at 3 months post-procedure was the percentage of subjects with FEV1 improvement from baseline of 12% or greater. Changes in FEV1, residual volume, 6-minute-walk distance, St. George's Respiratory Questionnaire score, and modified Medical Research Council score were assessed at 3 and 6 months, and target lobe volume reduction on chest computed tomography at 3 months. Measurements and Main Results: Ninety seven subjects were randomized toEBV(n = 65) or SoC(n = 32). At 3 months, 55.4% of EBV and 6.5% of SoC subjects had an FEV1 improvement of 12% or more (P <0.001). Improvements were maintained at 6 months: EBV 56.3% versus SoC 3.2% (P <0.001), with a mean +/- SD change in FEV1 at 6 months of 20.7 +/- 29.6% and -8.6 +/- 13.0%, respectively. A total of 89.8% of EBV subjects had target lobe volume reduction greater than or equal to 350 ml, mean 1.09 +/- 0.62 L (P <0.001). Between-group differences for changes at 6 months were statistically and clinically significant: Delta EBV-SoC for residual volume, -700 ml; 6-minute-walk distance, +78.7 m; St. George's Respiratory Questionnaire score, -6.5 points; modified Medical Research Council dyspnea score, -0.6 points; and BODE(body mass index, airflow obstruction, dyspnea, and exercise capacity) index, 21.8 points (all P <0.05). Pneumothorax was the most common adverse event, occurring in 19 of 65 (29.2%) of EBV subjects. Conclusions: EBV treatment in hyperinflated patients with heterogeneous emphysema without collateral ventilation resulted in clinically meaningful benefits in lung function, dyspnea, exercise tolerance, and quality of life, with an acceptable safety profile

    Selecting Patients for Lobar Lung Volume Reduction Therapy: What Quantitative Computed Tomography Parameters Matter?

    No full text
    PURPOSE  Evaluation of emphysema distribution with quantitative computed tomography (qCT) prior to endoscopic lung volume reduction (ELVR) is recommended. The aim of this study was to determine which of the commonly assessed qCT parameters prior to endoscopic lung volume reduction (ELVR) best predicts outcome of treatment. MATERIALS AND METHODS  50 patients who underwent technically successful ELVR at our institution were retrospectively analyzed. We performed quantitative analysis of the CT scans obtained prior to ELVR and carried out Mann-Whitney U-tests and a logistic regression analysis to identify the qCT parameters that predict successful outcome of ELVR in terms of improved forced expiratory volume in 1 second (FEV1). RESULTS  In the Mann-Whitney U-test, the interlobar emphysema heterogeneity index (p = 0.008) and the pulmonary emphysema score (p = 0.022) showed a statistically significant difference between responders and non-responders. In multiple logistic regression analysis only the interlobar emphysema heterogeneity index (p = 0.008) showed a statistically significant impact on the outcome of ELVR, while targeted lobe volume, total lung volume, targeted lobe emphysema score and total lung emphysema score did not. CONCLUSION  Of all commonly assessed quantitative CT parameters, only the heterogeneity index definitely allows prediction of ELVR outcome in patients with advanced chronic obstructive pulmonary disease (COPD). KEY POINTS   · Quantitative CT is recommended prior to ELVR.. · The relevance of the obtained parameters from quantitative CT remains controversial.. · This study confirms that only the emphysema heterogeneity index has a definite impact.. CITATION FORMAT · Theilig DC, Huebner R, Neumann K et al. Selecting Patients for Lobar Lung Volume Reduction Therapy: What Quantitative Computed Tomography Parameters Matter?. Fortschr Röntgenstr 2018; DOI: 10.1055/a-0638-0058

    Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    No full text
    PURPOSE To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. MATERIALS AND METHODS Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. RESULTS Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. CONCLUSION AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis

    Outcomes of Endobronchial Valve Treatment Based on the Precise Criteria of an Endobronchial Catheter for Detection of Collateral Ventilation under Spontaneous Breathing.

    No full text
    BACKGROUND Endoscopic lung volume reduction with valves is a valid therapeutic option for COPD patients with severe emphysema. The exclusion of interlobar collateral ventilation (CV) is an important predictor of clinical success. OBJECTIVES Recently, a catheter-based endobronchial in vivo measurement system (Chartis, Pulmonx, USA) has become routine in the clinical evaluation of CV status in target lobes, but the criteria for phenotyping CV by Chartis evaluation have not yet been defined. We asked the questions, how many phenotypes can be identified using Chartis, what are the exact criteria to distinguish them, and how do the Chartis phenotypes respond to valve insertion? METHODS In a retrospective study, 406 Chartis assessments of 166 patients with severe COPD were analyzed. Four Chartis phenotypes, CV positive (CV+), CV negative (CV-), low flow (LF) and low plateau were identified. Fifty-two patients without CV were treated with valves and followed for 3 months. RESULTS The Chartis phenotypes were discriminated with respect to decline in expiratory peak flow, increase in resistance index and change in total exhaled volume after 1, 2, 3, 4 and 5 min of measurement time (p 0.9). Compared to baseline, CV- and LF patients with ipsilateral CV- lobe showed an improvement in FEV1 (p < 0.05), vital capacity (p < 0.05) and target lobe volume reduction (p < 0.005) after valve insertion. CONCLUSION This study describes the most prevalent Chartis phenotypes

    Predicting Lung Volume Reduction after Endobronchial Valve Therapy Is Maximized Using a Combination of Diagnostic Tools

    No full text
    International audienceBronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) has been proven to be effective in patients with severe emphysema. However, the selection of patients without collateral ventilation prior to treatment is critical for procedural success. Collateral ventilation can be assessed directly with the Chartis system or indirectly using computed tomography (CT) fissure analysis.We retrospectively evaluated the diagnostic value of a combination of the quantitative CT interlobar fissure completeness score (FCS) and Chartis in predicting responders to EBV therapy.CT data from four prospective studies were pooled and analyzed using semiautomated software to quantify the completeness of interlobar fissures. These FCSs were compared to a reference standard of achieving ≄350 ml of target lobe volume reduction after EBV treatment. Using a receiver operating characteristic curve, optimal thresholds predictive of complete fissures (responders) and incomplete fissures (non-responders) were determined. A subgroup of patients with partially complete fissures was identified, where software had lower accuracy. The complementary value of Chartis was investigated in this group.A fissure was defined as complete (FCS >95%), incomplete (FCS <80%), or partially complete (80% < FCS < 95%). The positive predictive value (PPV) of complete fissures is 88.1%, and the negative predictive value (NPV) is 92.9%, with an overall accuracy of 89.2%. Chartis was utilized in patients with partially complete fissures, with a PPV of 82.3%, an NPV of 84.6%, and an accuracy of 83.3%.Combining diagnostic tools could reduce the burden on patients and the healthcare system while providing clinicians with a better means for patient selection for EBV therapy
    corecore