2,964 research outputs found

    Radiation Characteristics of 3D Resonant Cavity Antenna with Grid-Oscillator Integrated Inside

    Get PDF
    A three-dimensional (3D) rectangular cavity antenna with an aperture size of 80 mm × 80 mm and a length of 16 mm, integrated with a four-MESFET transistor grid-oscillator, is designed and studied experimentally. It is found that the use of 3D antenna resonant cavity in case of small or medium gain microwave active cavity antenna leads to effective and stable power combining and radiation. The lack of lateral cavity diffraction and radiation helps in producing a directive gain of about 17 dB and radiation aperture efficiency bigger than 75% at a resonance frequency of 8.62 GHz. Good DC to RF oscillator efficiency of 26%, effective isotropic radiated power (EIRP) of 5.2 W, and SSB spectral power density of −82 dBc/Hz are found from the measured data. The 3D antenna cavity serves also as a strong metal container for the solid-state oscillator circuitry

    Radiation Characteristics of 3D Resonant Cavity Antenna with Grid-Oscillator Integrated Inside

    Get PDF
    A three-dimensional (3D) rectangular cavity antenna with an aperture size of 80 mm × 80 mm and a length of 16 mm, integrated with a four-MESFET transistor grid-oscillator, is designed and studied experimentally. It is found that the use of 3D antenna resonant cavity in case of small or medium gain microwave active cavity antenna leads to effective and stable power combining and radiation. The lack of lateral cavity diffraction and radiation helps in producing a directive gain of about 17 dB and radiation aperture efficiency bigger than 75% at a resonance frequency of 8.62 GHz. Good DC to RF oscillator efficiency of 26%, effective isotropic radiated power (EIRP) of 5.2 W, and SSB spectral power density of −82 dBc/Hz are found from the measured data. The 3D antenna cavity serves also as a strong metal container for the solid-state oscillator circuitry

    Adipose-Derived Stem Cells in Crohn's Rectovaginal Fistula

    Get PDF
    Therapeutic options for recto-vaginal fistula in the setting of Crohn's disease are limited and many data are available in the literature. The manuscript describes the history of a patient who has been the pioneer of our Clinical Trials in treating this disease in fistulizing Crohn's disease environment. We believe it is the first time that a patient with this disease has been treated by adipose-derived stem cells in allogeneic form. The conclusion of our study with Mary is that the use of mesenchymal stem cells derived from adipose tissue is secure, either in autologous or allogeneic form. Furthermore, we have proved that if we use multi-dose and multiple applications on a patient, it does not produce any adverse effect, which confirms us the safety of using these cells in patients at least in the fistulizing Crohn's disease environment

    A Millimeter-wave Galactic Plane Survey with the BICEP Polarimeter

    Get PDF
    In order to study inflationary cosmology and the Milky Way Galaxy's composition and magnetic field structure, Stokes I, Q, and U maps of the Galactic plane covering the Galactic longitude range 260° < ℓ < 340° in three atmospheric transmission windows centered on 100, 150, and 220 GHz are presented. The maps sample an optical depth 1 ≾ AV ≾ 30, and are consistent with previous characterizations of the Galactic millimeter-wave frequency spectrum and the large-scale magnetic field structure permeating the interstellar medium. The polarization angles in all three bands are generally perpendicular to those measured by starlight polarimetry as expected and show changes in the structure of the Galactic magnetic field on the scale of 60°. The frequency spectrum of degree-scale Galactic emission is plotted between 23 and 220 GHz (including WMAP data) and is fit to a two-component (synchrotron and dust) model showing that the higher frequency BICEP data are necessary to tightly constrain the amplitude and spectral index of Galactic dust. Polarized emission is detected over the entire region within two degrees of the Galactic plane, indicating the large-scale magnetic field is oriented parallel to the plane of the Galaxy. A trend of decreasing polarization fraction with increasing total intensity is observed, ruling out the simplest model of a constant Galactic magnetic field orientation along the line of sight in the Galactic plane. A generally increasing trend of polarization fraction with electromagnetic frequency is found, varying from 0.5%-1.5% at frequencies below 50 GHz to 2.5%-3.5% above 90 GHz. The effort to extend the capabilities of BICEP by installing 220 GHz band hardware is described along with analysis of the new band

    The Cosmic Infrared Background Experiment (CIBER): Instrumentation and First Results

    Get PDF
    Ultraviolet emission from the first generation of stars in the Universe ionized the intergalactic medium in a process which was completed by z similar to 6; the wavelength of these photons has been redshifted by (1 + z) into the near infrared today and can be measured using instruments situated above the Earth's atmosphere. First flying in February 2009, the Cosmic Infrared Background ExpeRiment (CIBER) comprises four instruments housed in a single reusable sounding rocket borne payload. CIBER will measure spatial anisotropies in the extragalactic IR background caused by cosmological structure from the epoch of reionization using two broadband imaging instruments, make a detailed characterization of the spectral shape of the IR background using a low resolution spectrometer, and measure the absolute brightness of the Zodiacal light foreground with a high resolution spectrometer in each of our six science fields. The scientific motivation for CIBER and details of its first and second flight instrumentation will be discussed. First flight results on the color of the zodiacal light around 1 mu m and plans for the future will also be presented

    Observations of the Near-infrared Spectrum of the Zodiacal Light with CIBER

    Get PDF
    Interplanetary dust (IPD) scatters solar radiation which results in the zodiacal light that dominates the celestial diffuse brightness at optical and near-infrared wavelengths. Both asteroid collisions and cometary ejections produce the IPD, but the relative contribution from these two sources is still unknown. The low resolution spectrometer (LRS) onboard the Cosmic Infrared Background ExpeRiment (CIBER) observed the astrophysical sky spectrum between 0.75 and 2.1 μm over a wide range of ecliptic latitude. The resulting zodiacal light spectrum is redder than the solar spectrum, and shows a broad absorption feature, previously unreported, at approximately 0.9 μm, suggesting the existence of silicates in the IPD material. The spectral shape of the zodiacal light is isotropic at all ecliptic latitudes within the measurement error. The zodiacal light spectrum, including the extended wavelength range to 2.5 μm using Infrared Telescope in Space (IRTS) data, is qualitatively similar to the reflectance of S-type asteroids. This result can be explained by the proximity of S-type asteroidal dust to Earth's orbit, and the relatively high albedo of asteroidal dust compared with cometary dust

    Ultra-compact planoconcave zoned metallic lens based on the fishnet metamaterial

    Get PDF
    The following article appeared Pacheco-Pena, V., Orazbayev, B., Torres, V., Beruete, M., & Navarro-Cia, M. (n.d). Ultra-compact planoconcave zoned metallic lens based on the fishnet metamaterial. Applied Physics Letters, 103(18), and may be found at http://dx.doi.org/10.1063/1.4827876.A 1.5λ0 -thick planoconcave zoned lens based on the fishnet metamaterial is demonstrated experimentally at millimeter wavelengths. The zoning technique applied allows a volume reduction of 60% compared to a full fishnet metamaterial lens without any deterioration in performance. The structure is designed to exhibit an effective refractive index n = -0.25 at f = 56.7GHz (λ0 = 5.29 mm) with a focal length FL = 47.62 mm = 9λ0. The experimental enhancement achieved is 11.1dB, which is in good agreement with simulation and also with previous full fishnet metamaterial lenses and opens the door for integrated solutions.This work was supported in part by the Spanish Government under contract Consolider Engineering Metamaterials CSD2008-00066 and contract TEC2011- 28664-C02-01. V.P.-P. was sponsored by Spanish Ministerio de Educacion, Cultura y Deporte under Grant No. FPU AP- 2012-3796. B.O. was sponsored by Spanish Ministerio de Economıa y Competitividad under Grant No. FPI BES-2012- 054909. V.T. is sponsored by the Universidad Publica de Navarra. M.B. is sponsored by the Spanish Government via RYC-2011-08221. M.N.-C. was supported by the Imperial College Junior Research Fellowship

    The Cosmic Infrared Background Experiment (CIBER): A Sounding Rocket Payload to Study the Near Infrared Extragalactic Background Light

    Get PDF
    The Cosmic Infrared Background Experiment (CIBER) is a suite of four instruments designed to study the near infrared (IR) background light from above the Earth's atmosphere. The instrument package comprises two imaging telescopes designed to characterize spatial anisotropy in the extragalactic IR background caused by cosmological structure during the epoch of reionization, a low resolution spectrometer to measure the absolute spectrum of the extragalactic IR background, and a narrow band spectrometer optimized to measure the absolute brightness of the Zodiacal light foreground. In this paper we describe the design and characterization of the CIBER payload. The detailed mechanical, cryogenic, and electrical design of the system are presented, including all system components common to the four instruments. We present the methods and equipment used to characterize the instruments before and after flight, and give a detailed description of CIBER's flight profile and configurations. CIBER is designed to be recoverable and has flown twice, with modifications to the payload having been informed by analysis of the first flight data. All four instruments performed to specifications during the second flight, and the scientific data from this flight are currently being analyzed

    The Robinson Gravitational Wave Background Telescope (BICEP): a bolometric large angular scale CMB polarimeter

    Get PDF
    The Robinson Telescope (BICEP) is a ground-based millimeter-wave bolometric array designed to study the polarization of the cosmic microwave background radiation (CMB) and galactic foreground emission. Such measurements probe the energy scale of the inflationary epoch, tighten constraints on cosmological parameters, and verify our current understanding of CMB physics. Robinson consists of a 250-mm aperture refractive telescope that provides an instantaneous field-of-view of 17 degrees with angular resolution of 55 and 37 arcminutes at 100 GHz and 150 GHz, respectively. Forty-nine pair of polarization-sensitive bolometers are cooled to 250 mK using a 4He/3He/3He sorption fridge system, and coupled to incoming radiation via corrugated feed horns. The all-refractive optics is cooled to 4 K to minimize polarization systematics and instrument loading. The fully steerable 3-axis mount is capable of continuous boresight rotation or azimuth scanning at speeds up to 5 deg/s. Robinson has begun its first season of observation at the South Pole. Given the measured performance of the instrument along with the excellent observing environment, Robinson will measure the E-mode polarization with high sensitivity, and probe for the B-modes to unprecedented depths. In this paper we discuss aspects of the instrument design and their scientific motivations, scanning and operational strategies, and the results of initial testing and observations.Comment: 18 pages, 11 figures. To appear in Millimeter and Submillimeter Detectors and Instrumentation for Astronomy III, Proceedings of SPIE, 6275, 200
    corecore