1,817 research outputs found

    blaNDM-1 is a chimera likely constructed in acinetobacter baumannii

    Get PDF
    Alignment of DNA sequences found upstream of aphA6 and all blaNDM-1 genes displays 100% identity. This identity continues 19 bp into the blaNDM-1 gene such that the first 6 amino acids of aphA6 and blaNDM-1 are the same. Furthermore, the percent GC content (GC%) of aphA6 is considerably lower than that of blaNDM-1 and the GC% within the blaNDM-1 structural gene changes dramatically after the first 19 bp. This is unequivocal evidence that blaNDM-1 is a chimera

    Observational consequences of fine structure line optical depths on infrared spectral diagnostics

    Full text link
    It has long been known that infrared fine structure lines of abundant ions, like the [O III] 88 micron line, can become optically thick in H II regions under certain high luminosity conditions. This could mitigate their potential as diagnostic tools, especially if the source is too dusty for optical spectroscopy to otherwise determine the system's parameters. We examined a series of photoionization calculations which were designed to push the nebulae into the limit where many IR lines should be quite optically thick. We find that radiative transfer effects do not significantly change the observed emission line spectrum. This is due to a combination of grain absorption of the hydrogen ionizing continuum and the fact that the correction for stimulated emission in these lines is large. Given these results, and the likelihood that real objects have non-thermal line broadening, it seems unlikely that line optical depth presents a problem in using these lines as diagnostics of the physical conditions or chemical composition.Comment: 16 pages, 4 figures, to be published in the February 2003 issue of the PAS

    Oral administration of morphine versus ibuprofen to manage postfracture pain in children: A randomized trial

    Get PDF
    Background: Recent warnings from Health Canada regarding codeine for children have led to increased use of nonsteroidal anti-inflammatory drugs and morphine for common injuries such as fractures. Our objective was to determine whether morphine administered orally has superior efficacy to ibuprofen in fracture-related pain

    Quantification of Electromechanical Coupling to Prevent Inappropriate Implantable Cardioverter-Defibrillator Shocks

    Get PDF
    Objective To test specialised processing of laser Doppler signals for discriminating ventricular fibrillation(VF) from common causes of inappropriate therapies. Background Inappropriate ICD therapies remain a clinically important problem associated with morbidity and mortality. Tissue perfusion biomarkers, to assist automated diagnosis of VF, suffer the vulnerability of sometimes mistaking artefact and random noise for perfusion, which could lead to shocks being inappropriately withheld. Methods We developed a novel processing algorithm that combines electrogram data and laser Doppler perfusion monitoring, as a method for assessing circulatory status. We recruited 50 patients undergoing VF induction during ICD implantation. We recorded non-invasive laser Doppler and continuous electrograms, during both sinus-rhythm and VF. For each patient we simulated two additional scenarios that may lead to inappropriate shocks: ventricular-lead fracture and T-wave oversensing. We analysed the laser Doppler using three methods for reducing noise: (i)Running Mean, (ii)Oscillatory Height, (iii)a novel quantification of Electro-Mechanical coupling which gates laser Doppler against electrograms. We additionally tested the algorithm during exercise induced sinus tachycardia. Results Only the Electro-mechanical coupling algorithm found a clear perfusion cut-off between sinus rhythm and VF (sensitivity and specificity 100%). Sensitivity and specificity remained 100% during simulated lead fracture and electrogram oversensing. (AUC: Running Mean 0.91, Oscillatory Height 0.86, Electro-Mechanical Coupling 1.00). Sinus tachycardia did not cause false positives. Conclusions Quantifying the coupling between electrical and perfusion signals increases reliability of discrimination between VF and artefacts that ICDs may interpret as VF. Incorporating such methods into future ICDs may safely permit reductions of inappropriate shocks

    Calcaneal nonunion: three cases and a review of the literature

    Get PDF
    The long-term follow-up of intra-articular calcaneal fractures is often accompanied by complications. Frequently occurring are arthrosis, arthrofibrosis of the subtalar joint, and malunion. Uncommon is the calcaneal nonunion. A total of three cases is presented in this report, including a review of the literature. The occurrence of a nonunion appears to be more common after conservative treatment, but the pathophysiology remains unclear, however smoking may play a role

    Wave Intensity Analysis Provides Novel Insights Into Pulmonary Arterial Hypertension and Chronic Thromboembolic Pulmonary Hypertension.

    Get PDF
    BACKGROUND: In contrast to systemic hypertension, the significance of arterial waves in pulmonary hypertension (PH) is not well understood. We hypothesized that arterial wave energy and wave reflection are augmented in PH and that wave behavior differs between patients with pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH). METHODS AND RESULTS: Right heart catheterization was performed using a pressure and Doppler flow sensor-tipped catheter to obtain simultaneous pressure and flow velocity measurements in the pulmonary artery. Wave intensity analysis was subsequently applied to the acquired data. Ten control participants, 11 patients with PAH, and 10 patients with CTEPH were studied. Wave speed and wave power were significantly greater in PH patients compared with controls, indicating increased arterial stiffness and right ventricular work, respectively. The ratio of wave power to mean right ventricular power was lower in PAH patients than CTEPH patients and controls. Wave reflection index in PH patients (PAH: ≈25%; CTEPH: ≈30%) was significantly greater compared with controls (≈4%), indicating downstream vascular impedance mismatch. Although wave speed was significantly correlated to disease severity, wave reflection indexes of patients with mildly and severely elevated pulmonary pressures were similar. CONCLUSIONS: Wave reflection in the pulmonary artery increased in PH and was unrelated to severity, suggesting that vascular impedance mismatch occurs early in the development of pulmonary vascular disease. The lower wave power fraction in PAH compared with CTEPH indicates differences in the intrinsic and/or extrinsic ventricular load between the 2 diseases

    Complex Fluids and Hydraulic Fracturing

    Get PDF
    Nearly 70 years old, hydraulic fracturing is a core technique for stimulating hydrocarbon production in a majority of oil and gas reservoirs. Complex fluids are implemented in nearly every step of the fracturing process, most significantly to generate and sustain fractures and transport and distribute proppant particles during and following fluid injection. An extremely wide range of complex fluids are used: naturally occurring polysaccharide and synthetic polymer solutions, aqueous physical and chemical gels, organic gels, micellar surfactant solutions, emulsions, and foams. These fluids are loaded over a wide range of concentrations with particles of varying sizes and aspect ratios and are subjected to extreme mechanical and environmental conditions. We describe the settings of hydraulic fracturing (framed by geology), fracturing mechanics and physics, and the critical role that non-Newtonian fluid dynamics and complex fluids play in the hydraulic fracturing process

    Resection of the liver for colorectal carcinoma metastases - A multi-institutional study of long-term survivors

    Get PDF
    In this review of a collected series of patients undergoing hepatic resection for colorectal metastases, 100 patients were found to have survived greater than five years from the time of resection. Of these 100 long-term survivors, 71 remain disease-free through the last follow-up, 19 recurred prior to five years, and ten recurred after five years. Patient characteristics that may have contributed to survival were examined. Procedures performed included five trisegmentectomies, 32 lobectomies, 16 left lateral segmentectomies, and 45 wedge resections. The margin of resection was recorded in 27 patients, one of whom had a positive margin, nine of whom had a less than or equal to 1-cm margin, and 17 of whom had a greater than 1-cm margin. Eighty-one patients had a solitary metastasis to the liver, 11 patients had two metastases, one patient had three metastases, and four patients had four metastases. Thirty patients had Stage C primary carcinoma, 40 had Stage B primary carcinoma, and one had Stage A primarycarcinoma. The disease-free interval from the time of colon resection to the time of liver resection was less than one year in 65 patients, and greater than one year in 34 patients. Three patients had bilobar metastases. Four of the patients had extrahepatic disease resected simultaneously with the liver resection. Though several contraindications to hepatic resection have been proposed in the past, five-year survival has been found in patients with extrahepatic disease resected simultaneously, patients with bilobar metastases, patients with multiple metastases, and patients with positive margins. Five-year disease-free survivors are also present in each of these subsets. It is concluded that five-year survival is possible in the presence of reported contraindications to resection, and therefore that the decision to resect the liver must be individualized. © 1988 American Society of Colon and Rectal Surgeons

    Production of Magnetic Arsenic–Phosphorus Alloy Nanoribbons with Small Band Gaps and High Hole Conductivities

    Get PDF
    Quasi-1D nanoribbons provide a unique route to diversifying the properties of their parent 2D nanomaterial, introducing lateral quantum confinement and an abundance of edge sites. Here, a new family of nanomaterials is opened with the creation of arsenic–phosphorus alloy nanoribbons (AsPNRs). By ionically etching the layered crystal black arsenic–phosphorus using lithium electride followed by dissolution in amidic solvents, solutions of AsPNRs are formed. The ribbons are typically few-layered, several micrometers long with widths tens of nanometers across, and both highly flexible and crystalline. The AsPNRs are highly electrically conducting above 130 K due to their small band gap (ca. 0.035 eV), paramagnetic in nature, and have high hole mobilities, as measured with the first generation of AsP devices, directly highlighting their properties and utility in electronic devices such as near-infrared detectors, quantum computing, and charge carrier layers in solar cells
    • …
    corecore