85 research outputs found

    Sperm storage and mating in the deep-sea squid Taningia danae Joubin, 1931 (Oegopsida:Octopoteuthidae)

    Get PDF
    Spermatangium implantation is reported in the large oceanic squid Taningia danae, based on ten mated females from the stomachs of sperm whales. Implanted spermatangia were located in the mantle, head and neck (on both sides) or above the nuchal cartilage, under the neck collar and were often associated with incisions. These cuts ranged from 30 to 65 mm in length and were probably made by males, using the beak or arm hooks. This is the first time wounds facilitating spermatangium storage have been observed in the internal muscle layers (rather than external, as observed in some other species of squid). The implications of these observations for the mating behavior of the rarely encountered squid T. danae are discussed

    Food falls in the deep northwestern Weddell Sea

    Get PDF
    When pelagic organisms die and fall onto the deep-sea floor they create food falls, parcels of organic enrichment that subsidize deep benthic scavenging communities. The diversity and quantities of food falls remains unstudied for many ocean regions, since they are stochastically deposited and rapidly scavenged. The Southern Ocean habitat supports large populations of megafauna but few food falls have been documented. To investigate the diversity and quantity of food falls in the northwestern Weddell Sea we analyzed 8476 deep-sea floor images that were captured during the expedition PS118 on RV Polarstern in 2019 by the camera system OFOBS (Ocean Floor Observation and Bathymetry System). OFOBS was towed 1.5 m above the seafloor along five transects (400 to 2200 m seafloor depth) east of the Antarctic Peninsula. We observed the carcasses of one baleen whale, one penguin, and four fish at depths of 647 m, 613 m, 647 m, 2136 m, 2165 m, and 2112 m, respectively, as well as associated scavenging fauna. To the best of our knowledge, we describe here the first in situ observations of deep-sea food falls for penguins and fish in the Southern Ocean. While the whale carcass seemed in an intermediate successional stage, both the penguin and the fish were likely recently deposited and three of the fish potentially resulted from fishery discards. Our relatively small data set suggests that a diverse array of food falls provide nutrients to the slopes of the Powell Basin

    Impact of Intracranial Volume and Brain Volume on the Prognostic Value of Computed Tomography Perfusion Core Volume in Acute Ischemic Stroke

    Get PDF
    Background: Computed tomography perfusion (CTP)-estimated core volume is associated with functional outcomes in acute ischemic stroke. This relationship might differ among patients, depending on brain volume. Materials and Methods: We retrospectively included patients from the MR CLEAN Registry. Cerebrospinal fluid (CSF) and intracranial volume (ICV) were automatically segmented on NCCT. We defined the proportion of the ICV and total brain volume (TBV) affected by the ischemic core as ICVcore and TBVcore. Associations between the core volume, ICVcore, TBVcore, and functional outcome are reported per interquartile range (IQR). We calculated the area under the curve (AUC) to assess diagnostic accuracy.Results: In 200 patients, the median core volume was 13 (5–41) mL. Median ICV and TBV were 1377 (1283–1456) mL and 1108 (1020–1197) mL. Median ICVcore and TBVcore were 0.9 (0.4–2.8)% and 1.7 (0.5–3.6)%. Core volume (acOR per IQR 0.48 [95%CI 0.33–0.69]), ICVcore (acOR per IQR 0.50 [95%CI 0.35–0.69]), and TBVcore (acOR per IQR 0.41 95%CI 0.33–0.67]) showed a lower likelihood of achieving improved functional outcomes after 90 days. The AUC was 0.80 for the prediction of functional independence at 90 days for the CTP-estimated core volume, the ICVcore, and the TBVcore. Conclusion:Correcting the CTP-estimated core volume for the intracranial or total brain volume did not improve the association with functional outcomes in patients who underwent EVT.</p

    Association of thrombus density and endovascular treatment outcomes in patients with acute ischemic stroke due to M1 occlusions

    Get PDF
    PURPOSE: We aimed to study the association of non-contrast CT (NCCT) thrombus density with procedural and clinical outcomes in patients with acute ischemic stroke who underwent endovascular treatment (EVT). Since thrombus density is associated with thrombus location, we focused on M1 occlusions only.METHODS: Patients with available thin-slice (&lt; 2.5 mm) NCCT were included from a nationwide registry. Regression models were used to assess the relation between thrombus density (per Hounsfield unit [HU]) and the following outcomes. For reperfusion grade, adjusted common odds ratios (acOR) indicated a 1-step shift towards improved outcome per HU increase in thrombus density. For the binary outcomes of first-pass reperfusion (first-pass extended thrombolysis in cerebral infarction [eTICI] 2C-3, FPR), functional independence [90-day modified Rankin Scale (mRS) score of 0-2] and mortality), aORs were reported. Adjusted β coefficients (aβ) were reported for 24-h NIHSS and procedure duration in minutes. Outcome differences between first-line treatment devices (stent retriever versus aspiration) were assessed with interaction terms.RESULTS: In 566 patients with M1 occlusions, thrombus density was not associated with reperfusion (acOR 1.01, 95% CI 0.99-1.02), FPR (aOR 1.01, 95% CI 0.99-1.03), mortality (aOR 0.98, 95% CI 0.95-1.00), 24-h NIHSS (aβ - 0.7%, 95% CI - 1.4-0.2), or procedure duration (aβ 0.27, 95% CI - 0.05-0.58). In multivariable analysis, thrombus density was associated with functional independence (aOR 1.02, 95% CI 1.00-1.05). No interaction was found between thrombus density and first-line treatment device for any outcome.CONCLUSION: In patients with M1 occlusions, thrombus density was not clearly associated with procedural and clinical outcomes after EVT.</p

    The effectiveness and cost-evaluation of manual therapy and physical therapy in patients with sub-acute and chronic non specific neck pain. Rationale and design of a Randomized Controlled Trial (RCT)

    Get PDF
    Contains fulltext : 88910.pdf (publisher's version ) (Open Access)BACKGROUND: Manual Therapy applied to patients with non specific neck pain has been investigated several times. In the Netherlands, manual therapy as applied according to the Utrecht School of Manual Therapy (MTU) has not been the subject of a randomized controlled trial. MTU differs in diagnoses and treatment from other forms of manual therapy. METHODS/DESIGN: This is a single blind randomized controlled trial in patients with sub-acute and chronic non specific neck pain. Patients with neck complaints existing for two weeks (minimum) till one year (maximum) will participate in the trial. 180 participants will be recruited in thirteen primary health care centres in the Netherlands.The experimental group will be treated with MTU during a six week period. The control group will be treated with physical therapy (standard care, mainly active exercise therapy), also for a period of six weeks.Primary outcomes are Global Perceived Effect (GPE) and functional status (Neck Disability Index (NDI-DV)). Secondary outcomes are neck pain (Numeric Rating Scale (NRS)), Eurocol, costs and quality of life (SF36). DISCUSSION: This paper presents details on the rationale of MTU, design, methods and operational aspects of the trial. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00713843

    Value of Automatically Derived Full Thrombus Characteristics:An Explorative Study of Their Associations with Outcomes in Ischemic Stroke Patients

    Get PDF
    (1) Background: For acute ischemic strokes caused by large vessel occlusion, manually assessed thrombus volume and perviousness have been associated with treatment outcomes. However, the manual assessment of these characteristics is time-consuming and subject to inter-observer bias. Alternatively, a recently introduced fully automated deep learning-based algorithm can be used to consistently estimate full thrombus characteristics. Here, we exploratively assess the value of these novel biomarkers in terms of their association with stroke outcomes. (2) Methods: We studied two applications of automated full thrombus characterization as follows: one in a randomized trial, MR CLEAN-NO IV (n = 314), and another in a Dutch nationwide registry, MR CLEAN Registry (n = 1839). We used an automatic pipeline to determine the thrombus volume, perviousness, density, and heterogeneity. We assessed their relationship with the functional outcome defined as the modified Rankin Scale (mRS) at 90 days and two technical success measures as follows: successful final reperfusion, which is defined as an eTICI score of 2b-3, and successful first-pass reperfusion (FPS). (3) Results: Higher perviousness was significantly related to a better mRS in both MR CLEAN-NO IV and the MR CLEAN Registry. A lower thrombus volume and lower heterogeneity were only significantly related to better mRS scores in the MR CLEAN Registry. Only lower thrombus heterogeneity was significantly related to technical success; it was significantly related to a higher chance of FPS in the MR CLEAN-NO IV trial (OR = 0.55, 95% CI: 0.31–0.98) and successful reperfusion in the MR CLEAN Registry (OR = 0.88, 95% CI: 0.78–0.99). (4) Conclusions: Thrombus characteristics derived from automatic entire thrombus segmentations are significantly related to stroke outcomes.</p

    Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer

    Get PDF
    BACKGROUND: Reproducible measurements of the range of motion are an important prerequisite for the interpretation of study results. The digital inclinometer is considered to be a useful instrument because it is inexpensive and easy to use. No previous study assessed inter-observer reproducibility of range of motion measurements with a digital inclinometer by physical therapists in a large sample of patients. METHODS: Two physical therapists independently measured the passive range of motion of the glenohumeral abduction and the external rotation in 155 patients with shoulder pain. Agreement was quantified by calculation of the mean differences between the observers and the standard deviation (SD) of this difference and the limits of agreement, defined as the mean difference ± 1.96*SD of this difference. Reliability was quantified by means of the intraclass correlation coefficient (ICC). RESULTS: The limits of agreement were 0.8 ± 19.6 for glenohumeral abduction and -4.6 ± 18.8 for external rotation (affected side) and quite similar for the contralateral side and the differences between sides. The percentage agreement within 10° for these measurements were 72% and 70% respectively. The ICC ranged from 0.28 to 0.90 (0.83 and 0.90 for the affected side). CONCLUSIONS: The inter-observer agreement was found to be poor. If individual patients are assessed by two different observers, differences in range of motion of less than 20–25 degrees can not be distuinguished from measurement error. In contrast, acceptable reliability was found for the inclinometric measurements of the affected side and the differences between the sides, indicating that the inclimeter can be used in studies in which groups are compared
    corecore