25 research outputs found

    Son Altesse - Royale Marie - Thérèse Charlotte - de France, Madame, Duchesse d'Angoulême : [estampe]

    No full text
    Référence bibliographique : De Vinck, 5868Appartient à l’ensemble documentaire : Est19Vinc

    Cardiovascular Safety of Hydroxychloroquine–Azithromycin in 424 COVID-19 Patients

    No full text
    International audienceBackground and Objectives: Hydroxychloroquine (HCQ) combined with azithromycin (AZM) has been widely administered to patients with COVID-19 despite scientific controversies. In particular, the potential of prolong cardiac repolarization when using this combination has been discussed. Materials and Methods: We report a pragmatic and simple safety approach which we implemented among the first patients treated for COVID-19 in our center in early 2020. Treatment contraindications were the presence of severe structural or electrical heart disease, baseline corrected QT interval (QTc) > 500 ms, hypokalemia, or other drugs prolonging QTc that could not be interrupted. Electrocardiogram and QTc was evaluated at admission and re-evaluated after 48 h of the initial prescription. Results: Among the 424 consecutive adult patients (mean age 46.3 ± 16.1 years; 216 women), 21.5% patients were followed in conventional wards and 78.5% in a day-care unit. A total of 11 patients (2.6%) had contraindications to the HCQ-AZ combination. In the remaining 413 treated patients, there were no arrhythmic events in any patient during the 10-day treatment regimen. QTc was slightly but statistically significantly prolonged by 3.75 ± 25.4 ms after 2 days of treatment (p = 0.003). QTc prolongation was particularly observed in female outpatients 60 ms, and none had QTc > 500 ms. Conclusions: This report does not aim to contribute to knowledge of the efficacy of treating COVID-19 with HCQ-AZ. However, it shows that a simple initial assessment of patient medical history, electrocardiogram (ECG), and kalemia identifies contraindicated patients and enables the safe treatment of COVID-19 patients with HCQ-AZ. QT-prolonging anti-infective drugs can be used safely in acute life-threatening infections, provided that a strict protocol and close collaboration between infectious disease specialists and rhythmologists are applied

    Theophylline as an adjunct to control malignant ventricular arrhythmia associated with early repolarization

    No full text
    International audienceEarly repolarization (ER) has been associated with an increased risk of sudden cardiac arrest. Interestingly, ventricular arrhythmias seem to be triggered by parasympathetic stimulation. In the present case report, we describe complete control of highly frequent malignant ventricular arrhythmias after adding theophylline to ineffective oral hydroquinidine and high-rate pacing in a patient suffering from malignant ER. We hypothesize that the theophylline-mediated enhanced beta-adrenergic stimulation could reduce the transmural myocardial voltage discrepancy by increasing the inward ICa,L current

    Diaphragmatic CMAP Monitoring During Cryoballoon Procedures: Surface vs. Hepatic Recording Comparison and Limitations of This Approach

    No full text
    International audienceBackground Compound motor action potential (CMAP) monitoring is a common method used to prevent right phrenic nerve palsy during cryoballoon ablation for atrial fibrillation. Objective We compared recordings simultaneously obtained with surface and hepatic electrodes. Methods We included 114 consecutive patients (mean age 61.7 ± 10.9 years) admitted to our department for cryoballoon ablation. CMAP was monitored simultaneously with a hepatic catheter and a modified lead I ECG, whilst right phrenic nerve was paced before (stage 1) and during (stage 2) the right-sided freezes. If phrenic threat was detected with hepatic recordings (CMAP amplitude drop >30%) the application was discontinued with forced deflation. Results The ratio of CMAP/QRS was 4.63 (2.67–9.46) for hepatic and 0.76 (0.55–1.14) for surface ( p < 0.0001). Signal coefficients of variation during stage 1 were 3.92% (2.48–6.74) and 4.10% (2.85–5.96) ( p = 0.2177), respectively. Uninterpretable signals were more frequent on surface (median 10 vs. 0; p < 0.0001). For the 14 phrenic threats, the CMAP amplitude dropped by 35.61 ± 8.27% on hepatic signal and by 33.42 ± 11.58% concomitantly on surface ( p = 0.5417). Our main limitation was to achieve to obtain stable phrenic capture (57%). CMAP monitoring was not reliable because of pacing instability in 15 patients (13.16%). A palsy occurred in 4 patients (3.51%) because cryoapplication was halted too late. Conclusion Both methods are feasible with the same signal stability and amplitude drop precocity during phrenic threats. Clarity and legibility are significantly better with hepatic recording (sharper signals, less far-field QRS). The two main limitations were pacing instability and delay between 30% CMAP decrease and cryoapplication discontinuation

    Right ventricular and tricuspid valve function in patients chronically implanted with leadless pacemakers

    No full text
    Congress of the European-Society-of-Cardiology (ESC), Rome, ITALY, AUG 27-31, 2016International audienceno abstrac
    corecore