1,559 research outputs found

    Making sense?: The support of dispersed asylum seekers

    Get PDF
    Reforms of the system around the accommodation and support needs of asylum seekers entering the United Kingdom (UK), during the twentieth and early twenty-first centuries have meant that the support of asylum seekers has largely moved away from mainstream social work to be based within dedicated asylum support teams. This article investigates how the workers engaged as asylum support workers understand and make sense of their participation in the support of asylum seekers dispersed across the UK. By drawing upon qualitative research with asylum support workers this paper looks at how such workers make sense of their roles and how the ‘support’ of asylum seekers is conceived. The paper concludes that by working within this political and controversial area of work, workers are constantly finding ways to negotiate their support role within a dominant framework of control

    An improved single-step lysis protocol to measure luciferase bioluminescence in Plasmodium falciparum

    Get PDF
    This report describes the optimization and evaluation of a simple single-step lysis protocol to measure luciferase bioluminescence from genetically modified Plasmodium falciparum. This protocol utilizes a modified commercial buffer to improve speed of assay and consistency in the bioluminescence signal measured by reducing the manipulation steps required to release the cytoplasmic fraction. The utility of this improved assay protocol is demonstrated in typical assays that explore absolute and temporal gene expression activity

    Comparison of the absolute and relative efficiencies of electroporation-based transfection protocols for Plasmodium falciparum.

    Get PDF
    BACKGROUND: Several electroporation protocols exist to transfect exogenous DNA into Plasmodium falciparum. To date, however, only a subjective analysis of their relative efficiencies has been reported. METHODS: A time-course of luciferase reporter expression is used to provide an objective quantitative analysis of the absolute efficiency of three electroporation techniques; direct electroporation of ring stage infected erythrocytes, preloading of erythrocytes and a novel "double-tap" protocol that combines both approaches. RESULTS: Preloading of erythrocytes shows a mean efficiency of 9.59 x 10(-6), some 5-180 fold more efficient than matched experiments utilizing the "double-tap" and direct electroporation of ring stage infected erythrocytes alone, respectively. CONCLUSION: Evidence presented here provides the first quantitative assessment of both the absolute and relative efficiencies of a key molecular tool used to study the biology and pathogenesis of this important human pathogen

    Investigation of the antibiofilm capacity of peptide-modified stainless steel

    Get PDF
    Biofilm formation on surfaces is an important research topic in ship tribology and medical implants. In this study, dopamine and two types of synthetic peptides were designed and attached to 304 stainless steel surfaces, aiming to inhibit the formation of biofilms. A combinatory surface modification procedure was applied in which dopamine was used as a coupling agent, allowing a strong binding ability with the two peptides. X-ray photoelectron spectroscopy (XPS), elemental analysis, contact angle measurement and surface roughness test were used to evaluate the efficiency of the peptide modification. An antibiofilm assay against Staphylococcus aureus was conducted to validate the antibiofilm capacity of the peptide-modified stainless steel samples. XPS analysis confirmed that the optimal dopamine concentration was 40 µg ml−1 in the coupling reaction. Element analysis showed that dopamine and the peptides had bound to the steel surfaces. The robustness assay of the modified surface demonstrated that most peptide molecules had bound on the surface of the stainless steel firmly. The contact angle of the modified surfaces was significantly changed. Modified steel samples exhibited improved antibiofilm properties in comparison to untreated and dopamine-only counterpart, with the peptide 1 modification displaying the best antibiofilm effect. The modified surfaces showed antibacterial capacity. The antibiofilm capacity of the modified surfaces was also surface topography sensitive. The steel sample surfaces polished with 600# sandpaper exhibited stronger antibiofilm capacity than those polished with other types of sandpapers after peptide modification. These findings present valuable information for future antifouling material research

    Evaluation of bioluminescence-based assays of anti-malarial drug activity

    Get PDF
    Transgenic Plasmodium falciparum expressing luciferase offers an attractive bioluminescence-based assay platform for the investigation of the pharmacological properties of anti-malarial drugs. Here a side-by-side comparison of bioluminescence and fluorescence-based assays, utilizing a luciferase reporter cassette that confers a strong temporal pattern of luciferase expression during the S-phase of intraerythrocytic development, is reported

    Combinatorial Games with a Pass: A dynamical systems approach

    Full text link
    By treating combinatorial games as dynamical systems, we are able to address a longstanding open question in combinatorial game theory, namely, how the introduction of a "pass" move into a game affects its behavior. We consider two well known combinatorial games, 3-pile Nim and 3-row Chomp. In the case of Nim, we observe that the introduction of the pass dramatically alters the game's underlying structure, rendering it considerably more complex, while for Chomp, the pass move is found to have relatively minimal impact. We show how these results can be understood by recasting these games as dynamical systems describable by dynamical recursion relations. From these recursion relations we are able to identify underlying structural connections between these "games with passes" and a recently introduced class of "generic (perturbed) games." This connection, together with a (non-rigorous) numerical stability analysis, allows one to understand and predict the effect of a pass on a game.Comment: 39 pages, 13 figures, published versio

    Implementing a 48 h EWTD-compliant rota for junior doctors in the UK does not compromise patients’ safety : assessor-blind pilot comparison

    Get PDF
    Background: There are currently no field data about the effect of implementing European Working Time Directive (EWTD)-compliant rotas in a medical setting. Surveys of doctors’ subjective opinions on shift work have not provided reliable objective data with which to evaluate its efficacy. Aim: We therefore studied the effects on patient's safety and doctors’ work-sleep patterns of implementing an EWTD-compliant 48 h work week in a single-blind intervention study carried out over a 12-week period at the University Hospitals Coventry & Warwickshire NHS Trust. We hypothesized that medical error rates would be reduced following the new rota. Methods: Nineteen junior doctors, nine studied while working an intervention schedule of <48 h per week and 10 studied while working traditional weeks of <56 h scheduled hours in medical wards. Work hours and sleep duration were recorded daily. Rate of medical errors (per 1000 patient-days), identified using an established active surveillance methodology, were compared for the Intervention and Traditional wards. Two senior physicians blinded to rota independently rated all suspected errors. Results: Average scheduled work hours were significantly lower on the intervention schedule [43.2 (SD 7.7) (range 26.0–60.0) vs. 52.4 (11.2) (30.0–77.0) h/week; P < 0.001], and there was a non-significant trend for increased total sleep time per day [7.26 (0.36) vs. 6.75 (0.40) h; P = 0.095]. During a total of 4782 patient-days involving 481 admissions, 32.7% fewer total medical errors occurred during the intervention than during the traditional rota (27.6 vs. 41.0 per 1000 patient-days, P = 0.006), including 82.6% fewer intercepted potential adverse events (1.2 vs. 6.9 per 1000 patient-days, P = 0.002) and 31.4% fewer non-intercepted potential adverse events (16.6 vs. 24.2 per 1000 patient-days, P = 0.067). Doctors reported worse educational opportunities on the intervention rota. Conclusions: Whilst concerns remain regarding reduced educational opportunities, our study supports the hypothesis that a 48 h work week coupled with targeted efforts to improve sleep hygiene improves patient safety

    Fire Retardant Textiles

    Get PDF
    corecore