8 research outputs found
On the transverse mode of an atom laser
The transverse mode of an atom laser beam that is outcoupled from a
Bose-Einstein condensate is investigated and is found to be strongly determined
by the mean--field interaction of the laser beam with the condensate. Since for
repulsive interactions the geometry of the coupling scheme resembles an
interferometer in momentum space, the beam is found show filamentation.
Observation of this effect would prove the transverse coherence of an atom
laser beam.Comment: 4 pages, 4 figure
Clinical Study Maternal Hypotension during Fetoscopic Surgery: Incidence and Its Impact on Fetal Survival Outcomes
In this retrospective cohort study, we aimed to determine the incidence of intraoperative maternal hypotension during fetoscopic surgery for twin-twin transfusion syndrome (TTTS) and to evaluate the impact of intraoperative hypotension on fetal survival. A total of 328 TTTS patients with recipient twin cardiomyopathy who underwent fetoscopic surgery under epidural anesthesia were included. The exposure of interest was maternal medical therapy with nifedipine for the treatment of fetal cardiomyopathy. We found that intraoperative hypotension occurred in 53.4% (175/328 patients). There was no statistically significant difference in incidence of hypotension between nifedipine exposure and nonexposure groups (54.8% versus 50.8%, = 0.479). However, the nifedipine exposure group received a statistically significant higher dose of phenylephrine (7.04 ± 6.38 mcg/kg versus 4.70 ± 4.14 mcg/kg, = 0.018) and higher doses of other vasopressor, as counted by number of treatments (6.06 ± 4.58 versus 4.96 ± 3.42, = 0.022). There were no statistically significant differences in acute fetal survival rate (within 5 days) and fetal survival rate at birth between hypotensive and nonhypotensive patients. We concluded that preoperative exposure to nifedipine resulted in increased intraoperative maternal vasopressor requirement during fetoscopic surgery under epidural anesthesia. In patients who had intraoperative maternal hypotension, there was no correlation between the presence of maternal hypotension and postoperative fetal survival
Generic model of an atom laser
We present a generic model of an atom laser by including a pump and loss term
in the Gross-Pitaevskii equation. We show that there exists a threshold for the
pump above which the mean matter field assumes a non-vanishing value in
steady-state. We study the transient regime of this atom laser and find
oscillations around the stationary solution even in the presence of a loss
term. These oscillations are damped away when we introduce a position dependent
loss term. For this case we present a modified Thomas-Fermi solution that takes
into account the pump and loss. Our generic model of an atom laser is analogous
to the semi-classical theory of the laser.Comment: 15 pages, including 5 figures, submitted to Phys. Rev. A, revised
manuscript, file also available at
http://www.physik.uni-ulm.de/quan/users/kne
Increased Pain Reporting by Head and Neck Cancer Patients at Radiation Oncology Consultation: A Quality‐of‐Life Analysis
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/166159/1/lary28784.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/166159/2/lary28784_am.pd