97 research outputs found

    Agmatine protects retinal ganglion cells from hypoxia-induced apoptosis in transformed rat retinal ganglion cell line

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Agmatine is an endogenous polyamine formed by the decarboxylation of L-arginine. We investigated the protective effects of agmatine against hypoxia-induced apoptosis of immortalized rat retinal ganglion cells (RGC-5). RGC-5 cells were cultured in a closed hypoxic chamber (5% O<sub>2</sub>) with or without agmatine. Cell viability was determined by lactate dehydrogenase (LDH) assay and apoptosis was examined by annexin V and caspase-3 assays. Expression and phosphorylation of mitogen-activated protein kinases (MAPKs; JNK, ERK p44/42, and p38) and nuclear factor-kappa B (NF-κB) were investigated by Western immunoblot analysis. The effects of agmatine were compared to those of brain-derived neurotrophic factor (BDNF), a well-known protective neurotrophin for retinal ganglion cells.</p> <p>Results</p> <p>After 48 hours of hypoxic culture, the LDH assay showed 52.3% cell loss, which was reduced to 25.6% and 30.1% when agmatine and BDNF were administered, respectively. This observed cell loss was due to apoptotic cell death, as established by annexin V and caspase-3 assays. Although total expression of MAPKs and NF-κB was not influenced by hypoxic injury, phosphorylation of these two proteins was increased. Agmatine reduced phosphorylation of JNK and NF-κB, while BDNF suppressed phosphorylation of ERK and p38.</p> <p>Conclusion</p> <p>Our results show that agmatine has neuroprotective effects against hypoxia-induced retinal ganglion cell damage in RGC-5 cells and that its effects may act through the JNK and NF-κB signaling pathways. Our data suggest that agmatine may lead to a novel therapeutic strategy to reduce retinal ganglion cell injury related to hypoxia.</p

    Unilateral Recession-Resection Surgery with Inferior Displacement Combined with Augmented Anterior Transposition of Inferior Oblique Muscle

    Get PDF
    We report the effects of unilateral recession-resection surgery of the horizontal recti muscles with inferior displacement and augmented anterior transposition of the inferior oblique muscle with a posterior intermuscular suture in a patient with large exotropia and considerable hypertropia

    Full Tendon Transposition Augmented with Posterior Intermuscular Suture and Recession - Resection Surgery

    Get PDF
    Purpose: To report an effect of the full tendon transposition augmented with posterior intermuscular suture and recession-resection surgery, for the patient with monocular elevation deficiency (MED) and large exotropia. Methods: Interventional case report. Full tendon transposition augmented with posterior intermuscular suture and recession-resection surgery was performed for a 26-year-old male patient had monocular elevation deficiency (MED) and large exotropia. Results: Preoperative angle of deviation was 56 prism diopters (PD) hypotropia and 45 PD right exotropia, compared with 18 PD left hypertropia and 10 PD right esotropia postoperatively. Essotropia persisted after 2.5 years, however, and so the right medial rectus was recessed after removal of the previous posterior intermuscular suture. At a three-year follow-up after the second surgery, alignment was straight in the primary position at near and far distances. Conclusions: Full tendon transposition augmented with posterior intermuscular suture and recession-resection surgery was effective for a patient with MED associated with significant horizontal deviation, and a second operation was easily performed when overcorrection occurred.ope

    Pattern Visual Evoked Potential as a Predictor of Occlusion Therapy for Amblyopia

    Get PDF
    PURPOSE: This study was conducted to investigate the role of the pattern visual evoked potential (pVEP) as a predictor of occlusion therapy for patients with strabismic, anisometropic, and isometropic amblyopia. The secondary aim was to compare the characteristics of pVEP between strabismic and anisometropic amblyopia. METHODS: This retrospective comparative case series included 120 patients who had received occlusion therapy or a glasses prescription for correction of strabismic, anisometropic, and isometropic amblyopia (20 patients had strabismic amblyopia, 41 patients had anisometropic amblyopia, and 59 patients had isometropic amblyopia). For each patient, the value of the P100 latency on pVEP at the time of the initial diagnosis of amblyopia was collected. Subsequently, the P100 latency was compared according to types of amblyopia. Fifty of 120 patients (7 patients with strabismic amblyopia, 21 patients with anisometropic amblyopia, and 22 patients with isometropic amblyopia) who were followed-up for longer than 6 months were divided into two groups based on the value of their P100 latency (Group 1, P100 latency 120 msec or less; Group 2, P100 latency longer than 120 msec.) The amount of visual improvement after occlusion therapy or glasses was compared between two study groups. RESULTS: The mean P100 latency was 119.7+/-25.2 msec in eyes with strabismic amblyopia and 111.9+/-17.8 msec in eyes with non-strabismic (anisometropic or isometropic) amblyopia (p=0.213). In Group 1, the mean visual improvement after occlusion therapy or glasses was 3.69+/-2.14 lines on Dr. Hahn's standard test chart; in Group 2, the mean improvement was 2.27+/-2.21 lines (p=0.023). CONCLUSIONS: The P100 latency on pVEP at the time of initial diagnosis was significantly related to the visual improvement after occlusion therapy or glasses in patients with strabismic, anisometropic, and isometropic amblyopia. Therefore, it was presumed that patients with a delayed P100 latency might have less visual improvement after occlusion therapy or glasses. In addition, there was no apparent difference in P100 latency between patients with strabismic and non-strabismic (anisometropic or isometropic) amblyopia.ope

    Inter-Device Agreement of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Cirrus HD OCT

    Get PDF
    PURPOSE: To assess the inter-device agreement of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by 2 spectral domain Cirrus HD optical coherence tomography (OCT) devices in healthy Korean subjects. METHODS: Eleven eyes of 11 healthy volunteers were enrolled in the present study. Each eye was scanned with the Optic Disc Cube 200 x 200 scan of 2 Cirrus HD OCT devices for peripapillary RNFL thickness calculation. The inter-device agreements of the 2 Cirrus HD OCTs for average, quadrant, and clock-hour RNFL thickness values were determined with Wilcoxon signed rank test, Friedman test, Cronbach's alpha (alpha), intraclass correlation coefficient (ICC), coefficient of variation (COV), and Bland-Altman plot. RESULTS: The mean age of the participants was 25.82 +/- 3.28 years and all had a 0.00 logarithm of the minimum angle of resolution of best-corrected visual acuity. The signal strengths of scans from the 2 Cirrus HD OCT were not significantly different (p = 0.317). The inter-device agreement of average RNFL thickness was excellent (alpha, 0.940; ICC, 0.945; COV, 2.45 +/- 1.52%). However, the agreement of nasal quadrant RNFL thickness was not very good (alpha, 0.715; ICC, 0.716; COV, 5.72 +/- 4.64%). Additionally, on the Bland-Atman plot, the extent of agreement of the 2 Cirrus HD OCTs for RNFL thickness was variable according to scanned sectors. CONCLUSIONS: The inter-device agreement of 2 spectral domain Cirrus HD OCT devices for peripapillary RNFL thickness measurements was generally excellent but variable according to the scanned area. Thus, physicians should consider this fact before judging a change of RNFL thicknesses if they were measured by different OCT devices.ope

    The use of Taguchi method in the design of plastic injection mould for reducing warpage

    Get PDF
    Plastic injection moulding is one of the most important polymer processing operations in the plastic industry today. However, lack of skill in mould making and injection moulding machine control will lead to defective plastic product. Warpage is one type of defect that usually appears in products with thickness less than 1 mm. This project is going to fabricate a mould that produced a thin plate with dimension 120 mm × 50 mm × 1 mm. The thin plate will be used for warpage testing. In mould fabrication, the mould base that purchase will be machined and assembled. After that, the mould is fixed on the injection moulding machine. The machine setting should be made to produce the product. Then, the product will be used for testing on the effective factors in warpage problem by applying the experimental design of Taguchi method. From the results, it shows that the most effective factor on the warpage is melt temperature. The filling time only slightly influenced on the warpage. The optimum parameters that can minimize the warpage defect are melt temperature (240 °C), filling time (0.5 s), packing pressure (90%) and packing time (0.6 s)

    Relationship between the Retinal Thickness Analyzer and the GDx VCC Scanning Laser Polarimeter, Stratus OCT Optical Coherence Tomograph, and Heidelberg Retina Tomograph II Confocal Scanning Laser Ophthalmoscopy

    Get PDF
    PURPOSE: To assess the relationship between the retinal thickness analyzer (RTA) parameters, and those of the GDx VCC scanning laser polarimeter (GDx VCC), Stratus OCT optical coherence tomography (Stratus OCT), and Heidelberg retinal tomograph II confocal scanning laser ophthalmoscopy (HRT II). METHODS: Twenty-nine primary open-angle glaucoma patients were retrospectively included in this study. Measurements were obtained using the RTA, GDx VCC, Stratus OCT, and HRT II. We calculated the correlation coefficients between the parameters of RTA and those of the other studies. RESULTS: Among the optic disc parameters of RTA, the cup volume was best correlated with Stratus OCT (R=0.780, p<0.001) and HRT II (R=0.896, p<0.001). Among the posterior pole retinal thickness parameters, the posterior pole abnormally thin area (PPAT) of the RTA and the inferior average of the GDx VCC were best correlated (R=-0.596, p=0.001). The PPAT of the RTA and the inferior maximum of the Stratus OCT were best correlated (R=-0.489, p=0.006). The perifoveal minimum thickness (PFMT) of the RTA and the cup shape measurement of the HRT II were best correlated (R=-0.565, p=0.004). CONCLUSIONS: Many RTA optic disc parameters were significantly correlated with those of the Stratus OCT and HRT II. The RTA posterior pole retinal thickness parameters were significantly correlated with those of the GDx VCC, Stratus OCT and HRT II. The RTA optic disc and posterior pole retinal thickness parameters may be valuable in the diagnosis of glaucomaope

    Development of an Educational Robotic Training Kit.

    Get PDF
    Robotics is an applied science subject in engineering course that concerning control and automation in manufacturing industry now. Engineering students are forced to learn all theories and formulas that encompass the areas of mathematics, physics, micro-electronics, dynamics and kinematics, control systems, human factors, and manufacturing operation in a single subject without any hands-on practical skills. This paper provides an idea to break the barriers of conventional lecturing and laboratory exercising for engineering students with new development of educational robotic kit. This practical approach is able to support low cost robotics course and offers simple, time saving instruction outcomes to engineering students in the kinematics study of robot manipulators with consideration of structure design, serial servo circuit board, microcontroller programming, and graphical user interface (GUI) of PC controller. General architecture of 3-degree-of-freedom (DOF) robot manipulator with two links can be solved easily with the help of this robotic kit

    Transient Increase of Higher-Order Aberrations after Lateral Rectus Recession in Children

    Get PDF
    The changes of higher-order aberrations (HOAs) after bilateral lateral rectus muscle recession were evaluated. Forty eyes of 20 children were enrolled and their wavefront information was assessed until postoperative 3 months. Even though the root mean square (RMS) of total aberration was not changed, the RMS of HOA was transiently increased at postoperative 1 week and returned to baseline level after 1 month. Among individual Zernike coefficient, secondary astigmatism, quadrafoil, secondary coma, secondary trefoil, and pentafoil showed similar tendency with the RMS of HOA. However, coma, trefoil, and spherical aberration were not changed. Regarding recession amount, it did not correlate with any Zernike coefficient. In summary, our data imply that the HOAs are transiently increased after lateral rectus recession surgery. These results are in collusion with previous reports that strabismus surgery induced transient corneal astigmatism
    corecore