849 research outputs found

    Elevated levels of inflammatory cytokines predict survival in idiopathic and familial pulmonary arterial hypertension

    Get PDF
    BACKGROUND: Inflammation is a feature of pulmonary arterial hypertension (PAH), and increased circulating levels of cytokines are reported in patients with PAH. However, to date, no information exists on the significance of elevated cytokines or their potential as biomarkers. We sought to determine the levels of a range of cytokines in PAH and to examine their impact on survival and relationship to hemodynamic indexes. METHODS AND RESULTS: We measured levels of serum cytokines (tumor necrosis factor-alpha, interferon-gamma and interleukin-1beta, -2, -4, -5, -6, -8, -10, -12p70, and -13) using ELISAs in idiopathic and heritable PAH patients (n=60). Concurrent clinical data included hemodynamics, 6-minute walk distance, and survival time from sampling to death or transplantation. Healthy volunteers served as control subjects (n=21). PAH patients had significantly higher levels of interleukin-1beta, -2, -4, -6, -8, -10, and -12p70 and tumor necrosis factor-alpha compared with healthy control subjects. Kaplan-Meier analysis showed that levels of interleukin-6, 8, 10, and 12p70 predicted survival in patients. For example, 5-year survival with interleukin-6 levels of >9 pg/mL was 30% compared with 63% for patients with levels < or = 9 pg/mL (P=0.008). In this PAH cohort, cytokine levels were superior to traditional markers of prognosis such as 6-minute walk distance and hemodynamics. CONCLUSIONS: This study illustrates dysregulation of a broad range of inflammatory mediators in idiopathic and familial PAH and demonstrates that cytokine levels have a previously unrecognized impact on patient survival. They may prove to be useful biomarkers and provide insight into the contribution of inflammation in PAH

    Phorbol Esters and SDF-1 Induce Rapid Endocytosis and Down Modulation of the Chemokine Receptor CXCR4

    Get PDF
    The chemokine receptor CXCR4 is required, together with CD4, for entry by some isolates of HIV-1, particularly those that emerge late in infection. The use of CXCR4 by these viruses likely has profound effects on viral host range and correlates with the evolution of immunodeficiency. Stromal cell-derived factor-1 (SDF-1), the ligand for CXCR4, can inhibit infection by CXCR4-dependent viruses. To understand the mechanism of this inhibition, we used a monoclonal antibody that is specific for CXCR4 to analyze the effects of phorbol esters and SDF-1 on surface expression of CXCR4. On human T cell lines SupT1 and BC7, CXCR4 undergoes slow constitutive internalization (1.0% of the cell surface pool/min). Addition of phorbol esters increased this endocytosis rate >6-fold and reduced cell surface CXCR4 expression by 60 to 90% over 120 min. CXCR4 was internalized through coated pits and coated vesicles and subsequently localized in endosomal compartments from where it could recycle to the cell surface after removal of the phorbol ester. SDF-1 also induced the rapid down modulation (half time ∼5 min) of CXCR4. Using mink lung epithelial cells expressing CXCR4 and a COOH-terminal deletion mutant of CXCR4, we found that an intact cytoplasmic COOH-terminal domain was required for both PMA and ligand-induced CXCR4 endocytosis. However, experiments using inhibitors of protein kinase C indicated that SDF-1 and phorbol esters trigger down modulation through different cellular mechanisms

    Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system

    Get PDF
    The optically pumped magnetometer (OPM) is a viable means to detect magnetic fields generated by human brain activity. Compared to conventional detectors (superconducting quantum interference devices) OPMs are small, lightweight, flexible, and operate without cryogenics. This has led to a step change in instrumentation for magnetoencephalography (MEG), enabling a “wearable” scanner platform, adaptable to fit any head size, able to acquire data whilst subjects move, and offering improved data quality. Although many studies have shown the efficacy of ‘OPM-MEG’, one relatively untapped advantage relates to improved array design. Specifically, OPMs enable the simultaneous measurement of magnetic field components along multiple axes (distinct from a single radial orientation, as used in most conventional MEG systems). This enables characterisation of the magnetic field vector at all sensors, affording extra information which has the potential to improve source reconstruction. Here, we conduct a theoretical analysis of the critical parameters that should be optimised for effective source reconstruction. We show that these parameters can be optimised by judicious array design incorporating triaxial MEG measurements. Using simulations, we demonstrate how a triaxial array offers a dramatic improvement on our ability to differentiate real brain activity from sources of magnetic interference (external to the brain). Further, a triaxial system is shown to offer a marked improvement in the elimination of artefact caused by head movement. Theoretical results are supplemented by an experimental recording demonstrating improved interference reduction. These findings offer new insights into how future OPM-MEG arrays can be designed with improved performance

    Triaxial detection of the neuromagnetic field using optically-pumped magnetometry: feasibility and application in children

    Get PDF
    Optically-pumped magnetometers (OPMs) are an established alternative to superconducting sensors for magnetoencephalography (MEG), offering significant advantages including flexibility to accommodate any head size, uniform coverage, free movement during scanning, better data quality and lower cost. However, OPM sensor technology remains under development; there is flexibility regarding OPM design and it is not yet clear which variant will prove most effective for MEG. Most OPM-MEG implementations have either used single-axis (equivalent to conventional MEG) or dual-axis magnetic field measurements. Here we demonstrate use of a triaxial OPM formulation, able to characterise the full 3D neuromagnetic field vector. We show that this novel sensor is able to characterise magnetic fields with high accuracy and sensitivity that matches conventional (dual-axis) OPMs. We show practicality via measurement of biomagnetic fields from both the heart and the brain. Using simulations, we demonstrate how triaxial measurement offers improved cortical coverage, especially in infants. Finally, we introduce a new 3D-printed child-friendly OPM-helmet and demonstrate feasibility of triaxial measurement in a five-year-old. In sum, the data presented demonstrate that triaxial OPMs offer a significant improvement over dual-axis variants and are likely to become the sensor of choice for future MEG systems, particularly for deployment in paediatric populations

    Pointing control for the SPIDER balloon-borne telescope

    Full text link
    We present the technology and control methods developed for the pointing system of the SPIDER experiment. SPIDER is a balloon-borne polarimeter designed to detect the imprint of primordial gravitational waves in the polarization of the Cosmic Microwave Background radiation. We describe the two main components of the telescope's azimuth drive: the reaction wheel and the motorized pivot. A 13 kHz PI control loop runs on a digital signal processor, with feedback from fibre optic rate gyroscopes. This system can control azimuthal speed with < 0.02 deg/s RMS error. To control elevation, SPIDER uses stepper-motor-driven linear actuators to rotate the cryostat, which houses the optical instruments, relative to the outer frame. With the velocity in each axis controlled in this way, higher-level control loops on the onboard flight computers can implement the pointing and scanning observation modes required for the experiment. We have accomplished the non-trivial task of scanning a 5000 lb payload sinusoidally in azimuth at a peak acceleration of 0.8 deg/s2^2, and a peak speed of 6 deg/s. We can do so while reliably achieving sub-arcminute pointing control accuracy.Comment: 20 pages, 12 figures, Presented at SPIE Ground-based and Airborne Telescopes V, June 23, 2014. To be published in Proceedings of SPIE Volume 914

    What the Public Was Saying about the H1N1 Vaccine: Perceptions and Issues Discussed in On-Line Comments during the 2009 H1N1 Pandemic

    Get PDF
    During the 2009 H1N1 pandemic, a vaccine was made available to all Canadians. Despite efforts to promote vaccination, the public's intent to vaccinate remained low. In order to better understand the public's resistance to getting vaccinated, this study addressed factors that influenced the public's decision making about uptake. To do this, we used a relatively novel source of qualitative data – comments posted on-line in response to news articles on a particular topic. This study analysed 1,796 comments posted in response to 12 articles dealing with H1N1 vaccine on websites of three major Canadian news sources. Articles were selected based on topic and number of comments. A second objective was to assess the extent to which on-line comments can be used as a reliable data source to capture public attitudes during a health crisis. The following seven themes were mentioned in at least 5% of the comments (% indicates the percentage of comments that included the theme): fear of H1N1 (18.8%); responsibility of media (17.8%); government competency (17.7%); government trustworthiness (10.7%); fear of H1N1 vaccine (8.1%); pharmaceutical companies (7.6%); and personal protective measures (5.8%). It is assumed that the more frequently a theme was mentioned, the more that theme influenced decision making about vaccination. These key themes for the public were often not aligned with the issues and information officials perceived, and conveyed, as relevant in the decision making process. The main themes from the comments were consistent with results from surveys and focus groups addressing similar issues, which suggest that on-line comments do provide a reliable source of qualitative data on attitudes and perceptions of issues that emerge in a health crisis. The insights derived from the comments can contribute to improved communication and policy decisions about vaccination in health crises that incorporate the public's views

    Dietary supplementation with inulin-propionate ester or inulin improves insulin sensitivity in adults with overweight and obesity with distinct effects on the gut microbiota, plasma metabolome and systemic inflammatory responses: a randomised cross-over trial

    Get PDF
    Objective: To investigate the underlying mechanisms behind changes in glucose homeostasis with delivery of propionate to the human colon by comprehensive and coordinated analysis of gut bacterial composition, plasma metabolome and immune responses. Design: Twelve non-diabetic adults with overweight and obesity received 20 g/day of inulin-propionate ester (IPE), designed to selectively deliver propionate to the colon, a high-fermentable fibre control (inulin) and a low-fermentable fibre control (cellulose) in a randomised, double-blind, placebo-controlled, cross-over design. Outcome measurements of metabolic responses, inflammatory markers and gut bacterial composition were analysed at the end of each 42-day supplementation period. Results: Both IPE and inulin supplementation improved insulin resistance compared with cellulose supplementation, measured by homeostatic model assessment 2 (mean±SEM 1.23±0.17 IPE vs 1.59±0.17 cellulose, p=0.001; 1.17±0.15 inulin vs 1.59±0.17 cellulose, p=0.009), with no differences between IPE and inulin (p=0.272). Fasting insulin was only associated positively with plasma tyrosine and negatively with plasma glycine following inulin supplementation. IPE supplementation decreased proinflammatory interleukin-8 levels compared with cellulose, while inulin had no impact on the systemic inflammatory markers studied. Inulin promoted changes in gut bacterial populations at the class level (increased Actinobacteria and decreased Clostridia) and order level (decreased Clostridiales) compared with cellulose, with small differences at the species level observed between IPE and cellulose. Conclusion: These data demonstrate a distinctive physiological impact of raising colonic propionate delivery in humans, as improvements in insulin sensitivity promoted by IPE and inulin were accompanied with different effects on the plasma metabolome, gut bacterial populations and markers of systemic inflammation

    Assessing the Quality of Decision Support Technologies Using the International Patient Decision Aid Standards instrument (IPDASi)

    Get PDF
    Objectives To describe the development, validation and inter-rater reliability of an instrument to measure the quality of patient decision support technologies (decision aids). Design Scale development study, involving construct, item and scale development, validation and reliability testing. Setting There has been increasing use of decision support technologies – adjuncts to the discussions clinicians have with patients about difficult decisions. A global interest in developing these interventions exists among both for-profit and not-for-profit organisations. It is therefore essential to have internationally accepted standards to assess the quality of their development, process, content, potential bias and method of field testing and evaluation. Methods Scale development study, involving construct, item and scale development, validation and reliability testing. Participants Twenty-five researcher-members of the International Patient Decision Aid Standards Collaboration worked together to develop the instrument (IPDASi). In the fourth Stage (reliability study), eight raters assessed thirty randomly selected decision support technologies. Results IPDASi measures quality in 10 dimensions, using 47 items, and provides an overall quality score (scaled from 0 to 100) for each intervention. Overall IPDASi scores ranged from 33 to 82 across the decision support technologies sampled (n = 30), enabling discrimination. The inter-rater intraclass correlation for the overall quality score was 0.80. Correlations of dimension scores with the overall score were all positive (0.31 to 0.68). Cronbach's alpha values for the 8 raters ranged from 0.72 to 0.93. Cronbach's alphas based on the dimension means ranged from 0.50 to 0.81, indicating that the dimensions, although well correlated, measure different aspects of decision support technology quality. A short version (19 items) was also developed that had very similar mean scores to IPDASi and high correlation between short score and overall score 0.87 (CI 0.79 to 0.92). Conclusions This work demonstrates that IPDASi has the ability to assess the quality of decision support technologies. The existing IPDASi provides an assessment of the quality of a DST's components and will be used as a tool to provide formative advice to DSTs developers and summative assessments for those who want to compare their tools against an existing benchmark
    corecore