1,991 research outputs found

    Modelling optically pumped magnetometer interference in MEG as a spatially homogeneous magnetic field

    Get PDF
    Here we propose that much of the magnetic interference observed when using optically pumped magnetometers for MEG experiments can be modeled as a spatially homogeneous magnetic field. We show that this approximation reduces sensor level variance and substantially improves statistical power. This model does not require knowledge of the underlying neuroanatomy nor the sensor positions. It only needs information about the sensor orientation. Due to the model's low rank there is little risk of removing substantial neural signal. However, we provide a framework to assess this risk for any sensor number, design or subject neuroanatomy. We find that the risk of unintentionally removing neural signal is reduced when multi-axis recordings are performed. We validated the method using a binaural auditory evoked response paradigm and demonstrated that removing the homogeneous magnetic field increases sensor level SNR by a factor of 3. Considering the model's simplicity and efficacy, we suggest that this homogeneous field correction can be a powerful preprocessing step for arrays of optically pumped magnetometers

    Imaging the human hippocampus with optically-pumped magnetoencephalography

    Get PDF
    Optically-pumped (OP) magnetometers allow magnetoencephalography (MEG) to be performed while a participant’s head is unconstrained. To fully leverage this new technology, and in particular its capacity for mobility, the activity of deep brain structures which facilitate explorative behaviours such as navigation, must be detectable using OP-MEG. One such crucial brain region is the hippocampus. Here we had three healthy adult participants perform a hippocampal-dependent task – the imagination of novel scene imagery – while being scanned using OPMEG. A conjunction analysis across these three participants revealed a significant change in theta power in the medial temporal lobe. The peak of this activated cluster was located in the anterior hippocampus. We repeated the experiment with the same participants in a conventional SQUID-MEG scanner and found similar engagement of the medial temporal lobe, also with a peak in the anterior hippocampus. These OP-MEG findings indicate exciting new opportunities for investigating the neural correlates of a range of crucial cognitive functions in naturalistic contexts including spatial navigation, episodic memory and social interactions

    Clinical and genetic analysis of 29 Brazilian patients with Huntington’s disease-like phenotype

    Get PDF
    Huntington’s disease (HD) is a neurodegenerative disorder characterized by chorea, behavioral disturbances and dementia, caused by a pathological expansion of the CAG trinucleotide in the HTT gene. Several patients have been recognized with the typical HD phenotype without the expected mutation. The objective of this study was to assess the occurrence of diseases such as Huntington’s disease-like 2 (HDL2), spinocerebellar ataxia (SCA) 1, SCA2, SCA3, SCA7, dentatorubral-pallidoluysian atrophy (DRPLA) and choreaacanthocytosis (ChAc) among 29 Brazilian patients with a HD-like phenotype. In the group analyzed, we found 3 patients with HDL2 and 2 patients with ChAc. The diagnosis was not reached in 79.3% of the patients. HDL2 was the main cause of the HD-like phenotype in the group analyzed, and is attributable to the African ancestry of this population. However, the etiology of the disease remains undetermined in the majority of the HD negative patients with HD-like phenotype. Key words: Huntington’s disease, Huntington’s disease-like, chorea-acanthocytosis, Huntington’s disease-like 2

    Non-invasive measurements of ictal and interictal epileptiform activity using optically pumped magnetometers

    Get PDF
    Magneto- and electroencephalography (MEG/EEG) are important techniques for the diagnosis and pre-surgical evaluation of epilepsy. Yet, in current cryogen-based MEG systems the sensors are offset from the scalp, which limits the signal-to-noise ratio (SNR) and thereby the sensitivity to activity from deep structures such as the hippocampus. This effect is amplified in children, for whom adult-sized fixed-helmet systems are typically too big. Moreover, ictal recordings with fixed-helmet systems are problematic because of limited movement tolerance and/or logistical considerations. Optically Pumped Magnetometers (OPMs) can be placed directly on the scalp, thereby improving SNR and enabling recordings during seizures. We aimed to demonstrate the performance of OPMs in a clinical population. Seven patients with challenging cases of epilepsy underwent MEG recordings using a 12-channel OPM-system and a 306-channel cryogen-based whole-head system: three adults with known deep or weak (low SNR) sources of interictal epileptiform discharges (IEDs), along with three children with focal epilepsy and one adult with frequent seizures. The consistency of the recorded IEDs across the two systems was assessed. In one patient the OPMs detected IEDs that were not found with the SQUID-system, and in two patients no IEDs were found with either system. For the other patients the OPM data were remarkably consistent with the data from the cryogenic system, noting that these were recorded in different sessions, with comparable SNRs and IED-yields overall. Importantly, the wearability of OPMs enabled the recording of seizure activity in a patient with hyperkinetic movements during the seizure. The observed ictal onset and semiology were in agreement with previous video- and stereo-EEG recordings. The relatively affordable technology, in combination with reduced running and maintenance costs, means that OPM-based MEG could be used more widely than current MEG systems, and may become an affordable alternative to scalp EEG, with the potential benefits of increased spatial accuracy, reduced sensitivity to volume conduction/field spread, and increased sensitivity to deep sources. Wearable MEG thus provides an unprecedented opportunity for epilepsy, and given its patient-friendliness, we envisage that it will not only be used for presurgical evaluation of epilepsy patients, but also for diagnosis after a first seizure

    Hijacking ZIP codes: posttanscriptional regulation of CCN2 by nucleophosmin

    Get PDF
    CCN2 (connective tissue growth factor [CTGF]/hypertrophic chondrocyte-specific gene product 24 [Hcs24]) is regulated at the transcriptional and posttranscriptional level. For example, an element in the its 3′ untranslated region (3′-UTR) of the CCN2 mRNA controls message stability in chondrocytes. In a recent study, Mukudai et al. (Mol Cell Biol 28:6134-6147, 2008) purified and identified a trans-factor protein binding to the minimal repressive cis element in the 3′-UTR of ccn2 mRNA and identify this protein as the multifunctional nucleolar phosphoprotein nucleophosmin (NPM) This commentary summarizes these observations

    Optically pumped magnetoencephalography in epilepsy

    Get PDF
    We demonstrate the first use of Optically Pumped Magnetoencephalography (OP-MEG) in an epilepsy patient with unrestricted head movement. Current clinical MEG uses a traditional SQUID system, where sensors are cryogenically cooled and housed in a helmet in which the patient's head is fixed. Here, we use a different type of sensor (OPM), which operates at room temperature and can be placed directly on the patient's scalp, permitting free head movement. We performed OP-MEG recording in a patient with refractory focal epilepsy. OP-MEG-identified analogous interictal activity to scalp EEG, and source localized this activity to an appropriate brain region

    Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography

    Get PDF
    One of the most severe limitations of functional neuroimaging techniques, such as magnetoencephalography (MEG), is that participants must maintain a fixed head position during data acquisition. This imposes restrictions on the characteristics of the experimental cohorts that can be scanned and the experimental questions that can be addressed. For these reasons, the use of ‘wearable’ neuroimaging, in which participants can move freely during scanning, is attractive. The most successful example of wearable neuroimaging is electroencephalography (EEG), which employs lightweight and flexible instrumentation that makes it useable in almost any experimental setting. However, EEG has major technical limitations compared to MEG, and therefore the development of wearable MEG, or hybrid MEG/EEG systems, is a compelling prospect. In this paper, we combine and compare EEG and MEG measurements, the latter made using a new generation of optically-pumped magnetometers (OPMs). We show that these new second generation commercial OPMs, can be mounted on the scalp in an ‘EEG-like’ cap, enabling the acquisition of high fidelity electrophysiological measurements. We show that these sensors can be used in conjunction with conventional EEG electrodes, offering the potential for the development of hybrid MEG/EEG systems. We compare concurrently measured signals, showing that, whilst both modalities offer high quality data in stationary subjects, OPM-MEG measurements are less sensitive to artefacts produced when subjects move. Finally, we show using simulations that OPM-MEG offers a fundamentally better spatial specificity than EEG. The demonstrated technology holds the potential to revolutionise the utility of functional brain imaging, exploiting the flexibility of wearable systems to facilitate hitherto impractical experimental paradigms

    Functional Network Changes in Hippocampal CA1 after Status Epilepticus Predict Spatial Memory Deficits in Rats

    Get PDF
    Status epilepticus (SE) is a common neurological emergency, which has been associated with subsequent cognitive impairments. Neuronal death in hippocampal CA1 is thought to be an important mechanism of these impairments. However, it is also possible that functional interactions between surviving neurons are important. In this study we recorded in vivo single-unit activity in the CA1 hippocampal region of rats while they performed a spatial memory task. From these data we constructed functional networks describing pyramidal cell interactions. To build the networks, we used maximum entropy algorithms previously applied only to in vitro data. We show that several months following SE pyramidal neurons display excessive neuronal synchrony and less neuronal reactivation during rest compared with those in healthy controls. Both effects predict rat performance in a spatial memory task. These results provide a physiological mechanism for SE-induced cognitive impairment and highlight the importance of the systems-level perspective in investigating spatial cognition

    A tool for functional brain imaging with lifespan compliance

    Get PDF
    The human brain undergoes significant functional and structural changes in the first decades of life, as the foundations for human cognition are laid down. However, non-invasive imaging techniques to investigate brain function throughout neurodevelopment are limited due to growth in head-size with age and substantial head movement in young participants. Experimental designs to probe brain function are also limited by the unnatural environment typical brain imaging systems impose. However, developments in quantum technology allowed fabrication of a new generation of wearable magnetoencephalography (MEG) technology with the potential to revolutionise electrophysiological measures of brain activity. Here we demonstrate a lifespan-compliant MEG system, showing recordings of high fidelity data in toddlers, young children, teenagers and adults. We show how this system can support new types of experimental paradigm involving naturalistic learning. This work reveals a new approach to functional imaging, providing a robust platform for investigation of neurodevelopment in health and disease

    Tenecteplase for ST-elevation myocardial infarction in a patient treated with drotrecogin alfa (activated) for severe sepsis: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Drotrecogin alfa (activated) (DrotAA), an activated protein C, promotes fibrinolysis in patients with severe sepsis. There are no reported cases or studies that address the diagnosis and treatment of myocardial infarction in septic patients treated with DrotAA.</p> <p>Case presentation</p> <p>A 59-year-old Caucasian man with septic shock secondary to community-acquired pneumonia treated with DrotAA, subsequently developed an ST-elevation myocardial infarction 12 hours after starting DrotAA. DrotAA was stopped and the patient was given tenecteplase thrombolysis resulting in complete resolution of ST-elevation and no adverse bleeding events. DrotAA was restarted to complete the 96-hour course. The sepsis resolved and the patient was discharged from hospital.</p> <p>Conclusion</p> <p>In patients with severe sepsis or septic shock complicated by myocardial infarction, it is difficult to determine if the myocardial infarction is an isolated event or caused by the sepsis process. The efficacy and safety of tenecteplase thrombolysis in septic patients treated with DrotAA need further study.</p
    • …
    corecore