16 research outputs found

    Inventory of current EU paediatric vision and hearing screening programmes

    Get PDF
    OBJECTIVE: To examine the diversity in paediatric vision and hearing screening programmes in Europe. METHODS: Themes for comparison of screening programmes derived from literature were used to compile three questionnaires on vision, hearing, and public health screening. Tests used, professions involved, age, and frequency of testing seem to influence sensitivity, specificity, and costs most. Questionnaires were sent to ophthalmologists, orthoptists, otolaryngologists, and audiologists involved in paediatric screening in all EU full-member, candidate, and associate states. Answers were cross-checked. RESULTS: Thirty-nine countries participated; 35 have a vision screening programme, 33 a nation-wide neonatal hearing screening programme. Visual acuity (VA) is measured in 35 countries, in 71% of these more than once. First measurement of VA varies from three to seven years of age, but is usually before age five. At age three and four, picture charts, including Lea Hyvarinen, are used most; in children over four, Tumbling-E and Snellen. As first hearing screening test, otoacoustic emission is used most in healthy neonates, and auditory brainstem response in premature newborns. The majority of hearing testing programmes are staged; children are referred after 1-4 abnormal tests. Vision screening is performed mostly by paediatricians, ophthalmologists, or nurses. Funding is mostly by health insurance or state. Coverage was reported as >95% in half of countries, but reporting was often not first-hand. CONCLUSION: Largest differences were found in VA charts used (12), professions involved in vision screening (10), number of hearing screening tests before referral (1-4), and funding sources (8)

    Hearing loss in Pompe disease revisited: results from a study of 24 children

    Get PDF
    Little information is available regarding the auditory function in Pompe patients. Hearing loss has been reported in classic infantile patients, but it is still unknown whether central nervous system involvement interferes with auditory function and whether enzyme replacement therapy can improve hearing. Audi

    Developmental links between trajectories of physical violence, vandalism, theft, and alcohol-drug use from childhood to adolescence

    Get PDF
    Differences in developmental trajectories of physical violence, vandalism, theft, and alcohol-drug use from ages 10 to 15 were studied. For females and for males, three trajectories of theft and of alcohol-drug use increased from 10 years to 15 years, while only the high trajectory of vandalism increased from ten to 14. All trajectories of physical violence decreased. Children who engaged in the high trajectories of vandalism, theft, and alcohol-drug use had a high probability of also being high in physical violence. Compared to males, females were less likely to be on the high trajectory of physical violence, and their trajectories of other antisocial behaviors were less strongly associated with high levels of physical violence. The results suggest that physical violence during pre-adolescence and adolescence has a different developmental pattern than other forms of antisocial behavior, and that its relation to these other forms of antisocial behavior differs by se

    Inventory of current EU paediatric vision and hearing screening programmes

    Get PDF
    Background: We examined the diversity in paediatric vision and hearing screening programmes in Europe. Methods: Themes relevant for comparison of screening programmes were derived from literature and used to compile three questionnaires on vision, hearing and public-health screening. Tests used, professions involved, age and frequency of testing seem to influence sensitivity, specificity and costs most. Questionnaires were sent to ophthalmologists, orthoptists, otolaryngologists and audiologists involved in paediatric screening in all EU fullmember, candidate and associate states. Answers were cross-checked. Results: Thirty-nine countries participated; 35 have a vision screening programme, 33 a nation-wide neonatal hearing screening programme. Visual acuity (VA) is measured in 35 countries, in 71% more than once. First measurement of VA varies from three to seven years of age, but is usually before the age of five. At age three and four picture charts, including Lea Hyvarinen are used most, in children over four Tumbling-E and Snellen. As first hearing screening test otoacoustic emission (OAE) is used most in healthy neonates, and auditory brainstem response (ABR) in premature newborns. The majority of hearing testing programmes are staged; children are referred after one to four abnormal tests. Vision screening is performed mostly by paediatricians, ophthalmologists or nurses. Funding is mostly by health insurance or state. Coverage was reported as >95% in half of countries, but reporting was often not first-hand. Conclusion: Largest differences were found in VA charts used (12), professions involved in vision screening (10), number of hearing screening tests before referral (1-4) and funding sources (8)

    Management of subglottic haemangioma

    No full text

    Inventory of current EU paediatric vision and hearing screening programmes

    No full text
    Objective: To examine the diversity in paediatric vision and hearing screening programmes in Europe. Methods: Themes for comparison of screening programmes derived from literature were used to compile three questionnaires on vision, hearing, and public health screening. Tests used, professions involved, age, and frequency of testing seem to influence sensitivity, specificity, and costs most. Questionnaires were sent to ophthalmologists, orthoptists, otolaryngologists, and audiologists involved in paediatric screening in all EU full-member, candidate, and associate states. Answers were crosschecked. Results: Thirty-nine countries participated; 35 have a vision screening programme, 33 a nation-wide neonatal hearing screening programme. Visual acuity (VA) is measured in 35 countries, in 71% of these more than once. First measurement of VA varies from three to seven years of age, but is usually before age five. At age three and four, picture charts, including Lea Hyvarinen, are used most; in children over four, Tumbling-E and Snellen. As first hearing screening test, otoacoustic emission is used most in healthy neonates, and auditory brainstem response in premature newborns. The majority of hearing testing programmes are staged; children are referred after 1-4 abnormal tests. Vision screening is performed mostly by paediatricians, ophthalmologists, or nurses. Funding is mostly by health insurance or state. Coverage was reported as >95% in half of countries, but reporting was often not first-hand. Conclusion: Largest differences were found in VA charts used (12), professions involved in vision screening (10), number of hearing screening tests before referral (1-4), and funding sources (8)

    Implementation of Newborn Hearing Screening in Albania

    Get PDF
    Newborn hearing screening (NHS) was implemented in Albania in four maternity hospitals in 2018 and 2019. Implementation outcome, screening outcome, and screening quality measures were evaluated. Infants were first screened by midwives and nurses before discharge from the maternity hospital and returned for follow-up screening. Acceptability, appropriateness, feasibility, adoption, fidelity, coverage, attendance, and stepwise and final-referral rates were assessed by onsite observations, interviews, questionnaires, and a screening database. A post hoc analysis was performed to identify reasons for loss to follow up (LTFU) in a multivariate logistic regression. In total, 22,818 infants were born, of which 96.6% were screened. For the second screening step, 33.6% of infants were LTFU, 40.4% for the third, and 35.8% for diagnostic assessment. Twenty-two (0.1%) were diagnosed with hearing loss of ≥40 dB, six unilateral. NHS was appropriate and feasible: most infants are born in maternity hospitals, hence nurses and midwives could perform screening, and screening rooms and logistic support were supplied. Adoption among screeners was good. Referral rates decreased steadily, reflecting increasing skill. Occasionally, screening was repeated during a screening step, contrary to the protocol. NHS in Albania was implemented successfully, though LTFU was high. It is important to have effective data tracking and supervision throughout the screening

    Reliability of the reflux finding score for infants in flexible versus rigid laryngoscopy

    No full text
    The Reflux Finding Score for Infants (RFS-I) was developed to assess signs of laryngopharyngeal reflux (LPR) in infants. With flexible laryngoscopy, moderate inter- and highly variable intraobserver reliability was found. We hypothesized that the use of rigid laryngoscopy would increase reliability and therefore evaluated the reliability of the RFS-I for flexible versus rigid laryngoscopy in infants. We established a set of videos of consecutively performed flexible and rigid laryngoscopies in infants. The RFS-I was scored twice by 4 otorhinolaryngologists, 2 otorhinolaryngology fellows, and 2 inexperienced observers. Cohen's and Fleiss' kappas (k) were calculated for categorical data and the intraclass correlation coefficient (ICC) was calculated for ordinal data. The study set consisted of laryngoscopic videos of 30 infants (median age 7.5 (0-19.8) months). Overall interobserver reliability of the RFS-I was moderate for both flexible (ICC = 0.60, 95% CI 0.44-0.76) and rigid (ICC = 0.42, 95% CI 0.26-0.62) laryngoscopy. There were no significant differences in reliability of overall RFS-I scores and individual RFS-I items for flexible versus rigid laryngoscopy. Intraobserver reliability of the total RFS-I score ranged from fair to excellent for both flexible (ICC = 0.33-0.93) and rigid (ICC = 0.39-0.86) laryngoscopies. Comparing RFS-I results for flexible versus rigid laryngoscopy per observer, reliability ranged from no to substantial (k = -0.16-0.63, mean k = 0.22), with an observed agreement of 0.08-0.35. Reliability of the RFS-I was moderate and did not differ between flexible and rigid laryngoscopies. The RFS-I is not suitable to detect signs or to guide treatment of LPR in infants, neither with flexible nor with rigid laryngoscop
    corecore