162 research outputs found

    Comparative retrieval analysis of a novel anatomic tibial tray backside: alterations in tibial component design and surface coating can increase cement adhesions and surface roughness

    Get PDF
    Background: With the Persona® knee system a novel anatomic total knee design was developed, which has no pre-coating, whereas the predecessor knee system is pre-coated with polymethylmethacrylate (PMMA). Joint registry data have shown no decrease in risk of aseptic revision of PMMA pre-coated tibial components compared with non-pre-coated implants. The aim of this retrieval study was to compare the amount of cement adhesions, geometry and surface features between the two knee designs and to correlate them with the underlying reason for revision surgery. / Methods: Retrieval analysis was performed of 15 NexGen® and 8 Persona® fixed-bearing knee implants from the same manufacturer retrieved from two knee revision centres. A photogrammetric method was used to grade the amount of cement attached to the tibial tray backside. The geometry and dimensions of the tibial trays, tray projections and peripheral lips were measured using digital callipers and compared between the two different designs. To measure the surface roughness on the backside of the tibial tray, a contact profilometer was used. To investigate differences between the two designs statistical analyses (t-test) were performed. / Results: All Persona® trays showed evidence of cement adhesion with a % area of 75.4%; half of the NexGen® trays had cement adhesions, with a mean value of 20%. There was a significant difference in the percentage of area covered by cement between the two designs (p < 0.001). Results from the contact profilometer revealed that Persona® and NexGen® tray backsides showed a similar lateral (1.36 μm and 1.10 μm) and medial (1.39 μm and 1.12 μm) mean surface roughness with significant differentiation (p < 0.05) of the lateral and medial roughness values between the two designs. Persona® stems showed a significantly higher mean surface roughness (1.26) compared to NexGen® stems (0.89; p < 0.05). / Conclusion: The novel anatomic knee system showed significantly more cements adhesions and a higher surface roughness which was most likely attributed to the most obvious design and coating alteration of the tibial tray. This study provides first retrieval findings of a novel TKA design recently introduced to the market

    Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions.</p> <p>Methods</p> <p>We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity.</p> <p>Results</p> <p>Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology.</p> <p>Conclusions</p> <p>Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool.</p

    The ischiofemoral space of the hip is influenced by the frontal knee alignment

    Get PDF
    Purpose: The ischiofemoral distance (IFD), defined as the distance between the ischial tuberosity and the lesser trochanter of the femur, is gaining recognition as an extra-articular cause of hip pain. It is unknown whether the IFD is influenced by the frontal knee alignment. The aim of this study was to determine the influence of realignment surgery around the knee on the IFD. It was hypothesized that valgisation osteotomy around the knee is associated with reduction of the IFD. Methods: A consecutive series of 154 patients undergoing frontal realignment procedures around the knee in 2017 were included in this study. Long-leg standing radiographs were obtained before surgery and postoperatively. The IFD was measured between the ischium and the lesser trochanter at three different levels (proximal, middle and distal margins of the lesser trochanter parallel to the horizontal orientation of the pelvis) on standardized long-leg radiographs with the patient in upright standing position. The knee alignment was determined by measuring the hip knee ankle angle, mechanical lateral distal femur angle and the medial mechanical proximal tibia angle. Linear regression was performed to determine the influence of the change of frontal knee alignment on the IFD. Results: Linear regression showed a direct influence of the overall change in frontal knee alignment on the IFD of the hip, regardless of the site of the osteotomy (beta-0.4, confidence-interval - 0.5 to - 0.3, p < 0.001). Valgisation osteotomy around the knee induced a significant reduction of the ipsilateral IFD (p < 0.001), while varisation osteotomy induced a significant increase (p < 0.001). The amount of ISD change was 0.4 mm per corresponding degree of change in frontal knee alignment. Conclusion: These findings are relevant to both the hip and knee surgeons when planning an osteotomy or arthroplasty procedure. Correction of a malalignment of the knee may resolve an ischiofemoral conflict in the hip. The concept deserves inclusion in the diagnostic workup of both the hip and knee joints

    Adjustable loop ACL suspension devices demonstrate less reliability in terms of reproducibility and irreversible displacement.

    Get PDF
    PURPOSE The aim of this study was to perform a comprehensive biomechanical examination of frequently applied femoral cortical suspension devices, comparing the properties of both fixed and adjustable fixation mechanisms. It was hypothesized that adjustable loop devices demonstrate less consistent fixation properties with increased variability compared to fixed loop devices. METHODS Nine frequently applied fixation button types were tested, six adjustable and three rigid loop devices. Six samples of each device type were purchased. Each device was installed in a servo-hydraulic mechanical testing machine, running a 2000 cycle loading protocol at force increments between 50 and 500 N. Irreversible displacement in mm was measured for all of the tested samples of each implant. Ultimately, maximum load to failure was applied and measured in Nm. An irreversible displacement of 3 mm was considered failure of the implant. RESULTS Three of the six adjustable devices (GraftMax™, TightRope® ToggleLoc™) demonstrated a median displacement above the threshold of clinical failure before completion of the cycles. All adjustable loop devices showed a wide intragroup variation in terms of irreversible displacement, compared to fixed-loop devices. Fixed-loop devices provided consistent reproducible results with narrow ranges and significantly lower irreversible displacement (p < 0.05), the maximum being 1.4 mm. All devices withstood an ultimate force of more than 500 N. CONCLUSION Adjustable loop devices still show biomechanical inferiority and demonstrate heterogeneity of fixation properties with wide- and less-reproducible displacement ranges resultant to the mechanism of adjustment, denoting less reliability. However, three adjustable devices (RIGIDLOOP™ Adjustable, Ultrabutton ◊, ProCinch™) demonstrate fixation capacities within the margins of clinical acceptance. RIGIDLOOP™ Adjustable provides the most comparable fixation properties to fixed loop devices

    Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).</p> <p>Methods</p> <p>Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization scheme. Univariate analysis (Wilcoxon-Mann-Whitney, Spearmean`s-rho test, p < 0.05) was performed to identify any correlations between component position, tracer uptake and diagnosis.</p> <p>Results</p> <p>SPECT/CT imaging changed the suspected diagnosis and the proposed treatment in 19/23 (83%) knees. Progression of patellofemoral OA (n = 11), loosening of the tibial (n = 3) and loosening of the femoral component (n = 2) were identified as the leading causes of pain after TKA.</p> <p>Patients with externally rotated tibial trays showed higher tracer uptake in the medial patellar facet (p = 0.049) and in the femur (p = 0.051). Patients with knee pain due to patellofemoral OA showed significantly higher tracer uptake in the patella than others (p < 0.001).</p> <p>Conclusions</p> <p>SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patients with patellofemoral problems and malpositioned or loose TKA.</p

    An unusual case of persistent groin pain after total hip arthroplasty: a case report

    Get PDF
    ABSTRACT: INTRODUCTION: Arthroplasty is a well-established routine elective surgical procedure in orthopaedics. To a great extent, diagnosis, treatment and post-operative rehabilitation in these patients is standardised. In a busy clinic, surgeons from time to time tend to focus their attention on common causes of joint pain, but it may lead them to overlook sinister but less common pathologies. Here we report a case of a patient with groin pain due to pre-operatively undetected pelvic metastases from a pyeloureteral carcinoma who underwent total hip arthroplasty. There are several case reports which deal with primary or secondary tumours which were either discovered at the time of replacement surgery or developed at the site of prosthesis years after total hip or knee replacement. To the best of our knowledge, this is the first case report in which a metastatic cancer was missed pre-operatively and intra-operatively both by the radiologist and by the orthopaedic surgeon and should be reported so that surgeons are reminded to be careful when dealing with seemingly routine cases. CASE PRESENTATION: A 79-year-old Caucasian woman presented to the arthroplasty clinic with groin pain. Initial radiographs showed subtle bilateral abnormalities in the pelvis. Neither the radiologist nor the orthopaedic surgeon recognized it. A diagnosis of osteoarthritis of the hip was established, and she underwent total hip arthroplasty. Despite initial improvement, the patient came back with worsening hip pain three months later. Further radiological examination revealed multiple metastatic lesions throughout the pelvis due to a pyeloureteral carcinoma. CONCLUSIONS: This case report emphasizes the importance of meticulous, unbiased pre-operative assessment of patients and their radiographs, even in so-called routine clinical cases. Often subtle radiological changes are classed as normal, especially if they are bilateral. Further radiological imaging should be recommended in all cases where unexplained clinical features or radiological findings are present

    Stress avulsion of the tibial tuberosity after tension band wiring of a patellar fracture: a case report

    Get PDF
    INTRODUCTION: To the best of our knowledge there is no other report of an elderly patient who was surgically treated for a patellar fracture with tension band wiring and who subsequently suffered from an avulsion fracture of the tibial tuberosity. The combination of a patellar fracture and avulsion of the patellar ligament has only been described as complication after bone-patellar tendon-bone anterior cruciate ligament reconstructions. However, due to demographic changes and more elderly patients treated this injury may become more frequent in future. CASE PRESENTATION: We present the case of an 81 year old female who sustained an oblique patellar fracture after a direct contact injury of the left knee when falling on ice. Consequently the patellar fracture was openly reduced and stabilized with tension band wiring. The follow-up was uneventful till three months after surgery when the patient noticed a spontaneous avulsion fracture of the tibial tuberosity (Ogden type 3). The tibial tuberosity fragment was reattached with two non-resorbable sutures looped around two modified AO cortical 3.5 mm long neck screws. Intraoperatively multiple bone cysts were seen. Biopsies were not taken to prevent further fragmentation of the tibial tuberosity. The patient was followed up with anteroposterior and lateral full weight bearing radiographs and clinical assessment at 6, 12 weeks and 6 months after surgery. Recovery was completely pain free with full satisfaction. CONCLUSION: In conclusion in elderly patients with a patella fracture a possible associated but not obvious fracture of the tibial tuberosity should be ruled out and the postoperative rehabilitation protocol after tension band wiring of the patella might have to be individually adjusted to bone quality and course of the fracture

    Accelerated evidence synthesis in orthopaedics—the roles of natural language processing, expert annotation and large language models

    Get PDF
    peer reviewedIn an era of electronical medical records, rapidly expanding publication rates of medical knowledge, and large-scale registries, orthopaedics is in a dire need of innovative approaches to facilitate the adoption of the latest knowledge in clinical practice. While machine learning (ML) has been heralded as one solution to many research tasks hampered by previous technological limitations [12], there is an increasing need to direct our attention towards subdomains of ML that are convenient for the extraction of meaningful clinical information stored in medical records. We believe natural language processing (NLP) to be one such domain of ML, with an immense future potential to catalyse rate-limiting steps in orthopaedic research
    • …
    corecore