420 research outputs found

    International organisations and human rights: What direct authority needs for its legitimation

    Full text link
    Human rights violations by international organisations (IOs) are a possible side effect of their growing authority. Recent examples are the cases of sexual exploitation by UN peacekeepers and violations caused by IMF austerity measures. In response, IOs increasingly develop safeguards to protect human rights from being violated through their policies to regain legitimacy. We argue that this development can be accounted for by a mechanism we call ‘authority-legitimation mechanism’. We test this theoretical expectation against ten case studies on UN and EU sanctions policies, UN and NATO peacekeeping and World Bank and IMF lending. Next, we demonstrate inductively that the authority-legitimation mechanism can evolve through different pathways, depending on which actors get engaged. We label these pathways legislative institution-building if parliaments in member states put pressure on their governments to campaign for human rights safeguards in IOs, judicial institution-building if courts demand human rights safeguards, like-minded institution-building if civil society organisations, middle powers and IO bodies with little formal power push for human rights safeguards, or anticipatory institution-building if IOs adopt such safeguards from other IOs without having violated human rights themselves. Finally, we argue that which of these pathways are activated and how effective they are depends on specific conditions

    Double incision iso-anatomical ACL reconstruction: the freedom to place the femoral tunnel within the anatomical attachment site without exception

    Get PDF
    Aim: The present paper describes the rationale behind the surgical technique and the clinical results of the iso-anatomical, single bundle bone patellar-tendon bone anterior cruciate ligament (ACL) reconstruction. Method: Using a second incision on the distal lateral femur an outside-in femoral tunnel is drilled. Guided by a special aiming device it is possible to place the femoral tunnel in the centre of the ACL footprint in every single case. Conclusion: Since every crucial step of the procedure is under visual control, the technique is safe and reliable, which is mirrored by good clinical result

    Isoanatomical bone-patellar tendon-bone single-bundle ACL reconstruction: the wedge that gives the edge!

    Get PDF
    The purpose of the present paper is to describe the isoanatomical, single bundle, bone-patellar tendon-bone A3B-ACL reconstruction technique (A3B=Anatomical Bruderholz, Burkart, Biedert) in detail. The technical key factors and the pitfalls are highlighted. In addition, the pros and cons of the technique are discusse

    Quantification of bone strength by intraoperative torque measurement: a technical note

    Get PDF
    Introduction: Bone strength describes the resistance of bone against mechanical failure. Bone strength depends on both the amount of bone and the bone's quality, and the bone strength may be looked upon as a relevant parameter to judge an osteosynthesis' stability. Information about bone strength was barely available intraoperatively in the past. The previous work of our group reported on development and laboratory evaluation of mechanical torque measurement as a method for the intraoperative quantification of bone strength. With the clinical series presented here we intend to verify that the im gesamten Text DensiProbe™ instrumentation for intraoperative torque measurement and the related measurement method are eligible for intraoperative use based on the following criteria: application of the method may not create complications, the measurement can be performed by the surgeon himself and may only cause a limited increase in the procedure time. Patients and methods: From December 2006 until May 2007 ten patients with a pertrochanteric femoral fracture or a lateral femoral neck fracture eligible for stabilization with DHS® were included in the study after having received informed consent. Any medication and comorbidity that might have influenced bone quality or bone mineral density (BMD) in these patients was documented. Bone strength was intraoperatively measured with DensiProbe®. Complications that were obviously related with torque measurement were documented as well as any deviation from the suggested procedure; 6 and 12 weeks postoperative follow-up included clinical and radiological examination. The time required for torque measurement, the overall operating time and the number of persons present in the operating room were protocolled. BMD values of the contralateral femoral neck were postoperatively assessed by dual energy X-ray absorptiometry (DEXA) and compared to intraoperative peak torque values measured by DensiProbe®. Results: No major complication was observed during intraoperative application of DensiProbe®by trained surgeons. The unintended extraction of the guide wire together with the torque measurement probe was reported only once and is looked upon as a minor complication. Fracture healing was uneventful in all patients. The mean time for torque measurement was 2.35±0.9min accounting for 2.2±1.1% of total surgery time. The presence of an additional person was not required to perform torque measurement but to protocol the data. There was a tendency towards correlation between BMD values of the femoral neck and intraoperative peak torque values. Discussion: The data presented clearly indicate that the DensiProbe® instrumentation and measurement principle are eligible for routine intraoperative use by trained surgeons. Interpretation of possible correlations between BMD values measured by means of DEXA and the Peak Torque values assessed by DensiProbe® has to be considered very carefully, because BMD and Peak Torque analyse bone at a different scale. Only within the framework of a multicenter study it will be possible to include a sufficient number of patients for calculation of the methods' predictive value towards implant failure and to verify acceptance of the method by the surgeon

    Spreading recruitment over time to cope with environmental variability

    Get PDF
    10 paginas, 3 figuras, 2 tablas.-- El PDF es la versión de autor.Seedling establishment is one of the most vulnerable life cycle stages, and a key component for the population dynamics in short-lived plants. In unpredictable environments, timing of emergence is critical for the success of plant performance, and different adaptive bet-hedging strategies have evolved to reduce the risk of failure in recruitment. In this study we describe the spatio-temporal pattern of seedling emergence (overall rate and timing) and survival in four contrasting Mediterranean habitats for Plantago coronopus, a small herb with dimorphic seeds. We then explore the importance of spreading germination within years, as well as the role of the two types of seeds from a broader temporal perspective. Populations strongly differed for all recruitment components analyzed in a given year, but this spatial differentiation diluted when a longer period was considered. Apical (smaller) seeds germinated later and in a significantly lower proportion than basal (larger) seeds. Both late emergents and seedlings from apical seeds had lower survival probability in a rainy year. However, our results suggest that in a population having the lowest production of apical seeds, late emergents coming from apical seeds may constitute a large fraction of yearly recruitment and that their performance was non-significantly different from that of early emergents over the 4-year study period. This study provides evidence of the importance of two related traits (spreading seedling emergence through time by producing dimorphic seeds) as bet-hedging strategies to cope with environmental unpredictability. This is at least partly accomplished by increasing the potential of recruitment in favourable years, instead of buffering such important process in extremely bad years.This study was funded by the Spanish Ministry of Science, under projects BOS2002-01162 and CGL2006-08507 to MBG.Peer reviewe

    Standardized volumetric 3D-analysis of SPECT/CT imaging in orthopaedics: overcoming the limitations of qualitative 2D analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>SPECT/CT combines high resolution anatomical 3D computerized tomography (CT) and single photon emission computerized tomography (SPECT) as functional imaging, which provides 3D information about biological processes into a single imaging modality. The clinical utility of SPECT/CT imaging has been recognized in a variety of medical fields and most recently in orthopaedics; however, clinical adoption has been limited due to shortcomings of analytical tools available. Specifically, SPECT analyses are mainly qualitative due to variation in overall metabolic uptake among patients. Furthermore, most analyses are done in 2D, although rich 3D data are available. Consequently, it is difficult to quantitatively compare the position, size, and intensity of SPECT uptake regions among patients, and therefore difficult to draw meaningful clinical conclusions.</p> <p>Methods</p> <p>We propose a method for normalizing orthopaedic SPECT/CT data that enables standardised 3D volumetric quantitative measurements and comparison among patients. Our method is based on 3D localisation using clinically relevant anatomical landmarks and frames of reference, along with intensity value normalisation using clinically relevant reference regions. Using the normalised data, we describe a thresholding technique to distinguish clinically relevant hot spots from background activity.</p> <p>Results</p> <p>Using an exemplar comparison of two patients, we demonstrate how the normalised, 3D-rendered data can provide a richer source of clinical information and allow quantitative comparison of SPECT/CT measurements across patients. Specifically, we demonstrate how non-normalized SPECT/CT analysis can lead to different clinical conclusions than the normalized SPECT/CT analysis, and that normalized quantitative analysis can be a more accurate indicator of pathology.</p> <p>Conclusions</p> <p>Conventional orthopaedic frames of reference, 3D volumetric data analysis and thresholding are used to distinguish clinically relevant hot spots from background activity. Our goal is to facilitate a standardised approach to quantitative data collection and comparison of clinical studies using SPECT/CT, enabling more widespread clinical use of this powerful imaging tool.</p

    SPECT/CT tracer uptake is influenced by tunnel orientation and position of the femoral and tibial ACL graft insertion site

    Get PDF
    Purpose: SPECT/CT is a hybrid imaging modality, which combines a 3D scintigraphy (SPECT) and a conventional computerised tomography (CT). SPECT/CT allows accurate anatomical localisation of metabolic tracer activity. It allows the correlation of surgical factors such as tunnel position and orientation with mechanical alignment, clinical outcome and biological factors. The purpose of this study was to investigate whether the SPECT/CT tracer uptake (intensity and distribution) correlates with the stability and laxity of the knee joint and the position and orientation of the tibial and femoral tunnels in patients after anterior cruciate ligament (ACL) reconstruction. Methods: A consecutive series of knees (n = 66), with symptoms of pain and/or instability after ACL reconstruction were prospectively evaluated using clinical examination and 99mTc-HDP-SPECT/CT. Clinical laxity testing was performed using the Rolimeter (Ormed, Freiburg, Germany) including Lachman testing (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), anterior drawer test (0-2 mm, 3-5 mm, 6-10 mm, >10 mm), pivot shift test (positive versus negative) and patient-based subjective instability (yes versus no). For analysis of SPECT/CT tracer uptake a previously validated SPECT/CT localisation scheme consisting of 17 tibial, nine femoral and four patellar regions on standardised axial, coronal, and sagittal slices was used. The tracer activity on SPECT/CT was localised and recorded using a 3D volumetric and quantitative analysis software. Mean, standard deviation, minimum and maximum of grading for each area of the localisation scheme were recorded. The position and orientation of the tibial and femoral tunnel was assessed using a previously published method on 3D-CT. Results: Correlation of instability, pivot shift as well as clinical laxity testing with 99mTc-HDP-SPECT/CT tracer uptake intensity and distribution showed no significant correlation. 99mTc-HDP-SPECT/CT tracer uptake correlated significantly with the position and orientation of the ACL graft. A more horizontal femoral graft position showed significantly increased tracer uptake within the superior and posterior femoral regions. A more posteriorly-placed femoral insertion site showed significantly more tracer uptake within the femoral and tibial tunnel regions. A more vertical or a less medial tibial tunnel orientation showed significant increased uptake within the tibial and femoral tunnel regions. A more anterior tibial tunnel position showed significantly more tracer uptake in the femoral and tibial tunnel regions as well as the entire tibiofemoral joint. Conclusions: SPECT/CT tracer uptake intensity and distribution showed a significant correlation with the femoral and tibial tunnel position and orientation in patients with symptomatic knees after ACL reconstruction. No correlation was found with stability or clinical laxity. SPECT/CT tracer uptake distribution has the potential to give us important information on joint homeostasis and remodelling after ACL reconstruction. It might help to predict ACL graft failure and improve our surgical ACL reconstruction technique in finding the optimal tunnel and graft position and orientatio

    SPECT/CT in patients with painful knee arthroplasty—what is the evidence?

    Get PDF
    SPECT/CT is increasingly recognized as a promising imaging modality for the investigation of patients with a painful knee after knee arthroplasty. In this review article, we give an overview of the clinical value and current and future applications of SPECT/CT for patients with knee pain following joint arthroplasty. A detailed evidence-based literature review is performed and presente

    Comparative retrieval analysis of a novel anatomic tibial tray backside: alterations in tibial component design and surface coating can increase cement adhesions and surface roughness

    Get PDF
    Background: With the Persona® knee system a novel anatomic total knee design was developed, which has no pre-coating, whereas the predecessor knee system is pre-coated with polymethylmethacrylate (PMMA). Joint registry data have shown no decrease in risk of aseptic revision of PMMA pre-coated tibial components compared with non-pre-coated implants. The aim of this retrieval study was to compare the amount of cement adhesions, geometry and surface features between the two knee designs and to correlate them with the underlying reason for revision surgery. / Methods: Retrieval analysis was performed of 15 NexGen® and 8 Persona® fixed-bearing knee implants from the same manufacturer retrieved from two knee revision centres. A photogrammetric method was used to grade the amount of cement attached to the tibial tray backside. The geometry and dimensions of the tibial trays, tray projections and peripheral lips were measured using digital callipers and compared between the two different designs. To measure the surface roughness on the backside of the tibial tray, a contact profilometer was used. To investigate differences between the two designs statistical analyses (t-test) were performed. / Results: All Persona® trays showed evidence of cement adhesion with a % area of 75.4%; half of the NexGen® trays had cement adhesions, with a mean value of 20%. There was a significant difference in the percentage of area covered by cement between the two designs (p < 0.001). Results from the contact profilometer revealed that Persona® and NexGen® tray backsides showed a similar lateral (1.36 μm and 1.10 μm) and medial (1.39 μm and 1.12 μm) mean surface roughness with significant differentiation (p < 0.05) of the lateral and medial roughness values between the two designs. Persona® stems showed a significantly higher mean surface roughness (1.26) compared to NexGen® stems (0.89; p < 0.05). / Conclusion: The novel anatomic knee system showed significantly more cements adhesions and a higher surface roughness which was most likely attributed to the most obvious design and coating alteration of the tibial tray. This study provides first retrieval findings of a novel TKA design recently introduced to the market
    corecore