160 research outputs found

    Species, size, and location of “giant trees” in Tokyo’s urban area and western suburbs

    Get PDF
    The Japanese landscape has been characterised by the occurrence of ancient, massive trees described here as “giant trees”, and many of these have had major historic, cultural, and religious significance. However, modern Japan has experienced significant and rapid urbanisation and in relation to ancient woods and trees, “cultural severance” too. This study identified the species, size, and locations of the giant trees growing in Tokyo’s urban centre and its western suburbs, by conducting field surveys and collecting data from published studies. Classification of sites according to tree girth, with giant trees, revealed six broad locations: (1) forest and agricultural lands of managed secondary and later abandoned woodland with deciduous, broad-leaved trees; (2) public gardens, comprising useful and ornamental plants introduced from southern Japan; (3) parks, including mostly exotic species; (4) shrine sites, including Zelkova serrata, conifers, and evergreen broad-leaved trees; (5) temple sites, including many Torreya nucifera; and (6) Imperial lands, with rare species of trees in low numbers. The highest percentage of giant trees (36%) were found in parks, followed by temple and shrine sites (32%), whereas only 10% were found in other historical places. This study highlights the importance of studying giant tree habitats and history and identifying the relationships between human activities and living trees

    Factors Influencing Breast Density in Japanese Women Aged 40-49 in Breast Cancer Screening Mammography

    Get PDF
    A relatively large number of women in their 40s with high-density breasts, in which it can be difficult to detect lesions, are encountered in mammography cancer screenings in Japan. Here, we retrospectively investigated factors related to breast density. Two hundred women (40-49 years old) were examined at the screening center in our hospital. Multivariate analysis showed that factors such as small abdominal circumference, high HDL cholesterol, and no history of childbirth were related to high breast density in women in their 40s undergoing mammography. Other non-mammographic screening methods should be considered in women with abdominal circumferences <76cm, HDL-C >53mg/dl, and no history of childbirth, as there is a strong possibility of these women having high-density breasts that can make lesion detection difficult

    Evaluation of calibration factor of OSLD toward eye lens exposure dose measurement of medical staff during IVR

    Get PDF
    The eye lens is a sensitive organ of which an x‐ray exposure dose should be managed during interventional radiology (IVR). In the actual situations, the eye lens is exposed to scattered x‐rays; they have different from the standard x‐ray energies which are used for general dose calibration of the dosimeter. To perform precise dose measurement, the energy dependence of the dosimeter should be properly accounted for when calibrating the dosimeter. The vendor supplies a calibration factor using 80‐kV diagnostic x‐rays under a free‐air condition. However, whether it is possible to use this calibration factor to evaluate the air kerma during the evaluation of the eye lens dose is unclear. In this paper, we aim to precisely determine calibration factors, and also examine the possible application of using a vendor‐supplied calibration factor. First, the x‐ray spectrum at the eye lens position during fluoroscopy was measured with a CdTe x‐ray spectrometer. We mimicked transfemoral cardiac catheterization using a human‐type phantom. Second, we evaluated the doses and calibration factors at three dosimetric points: front and back of protective goggles, and the front of the head (eye lens position). We used the measured x‐ray spectrum to determine the incident photon distribution in the eye lens regions, and x‐ray spectra corresponding to the dosimetric points around the eye lens were estimated using Monte Carlo simulation. Although the calibration factors varied with dosimetric positions, we found that the factors obtained were similar to the vendor‐supplied calibration factor. Furthermore, based on the experiment, we propose a practical way to calibrate an OSL dosimeter in an actual clinical situation. A person evaluating doses can use a vendor‐supplied calibration factor without any corrections for energy dependences, only when they add a systematic uncertainty of 5%. This evidence will strongly support actual exposure dose measurement during a clinical study

    The Maximum Standardized Uptake Value Is More Reliable Than Size Measurement in Early Follow-up to Evaluate Potential Pulmonary Malignancies Following Radiofrequency Ablation

    Get PDF
    We retrospectively evaluated the accumulation of fluorodeoxy glucose (FDG) in pulmonary malignancies without local recurrence during 2-year follow-up on positron emission tomography (PET)/computed tomography (CT) after radiofrequency ablation (RFA). Thirty tumors in 25 patients were studied (10 non-small cell lung cancers;20 pulmonary metastatic tumors). PET/CT was performed before RFA, 3 months after RFA, and 6 months after RFA. We assessed the FDG accumulation with the maximum standardized uptake value (SUVmax) compared with the diameters of the lesions. The SUVmax had a decreasing tendency in the first 6 months and, at 6 months post-ablation, FDG accumulation was less affected by inflammatory changes than at 3 months post-RFA. The diameter of the ablated lesion exceeded that of the initial tumor at 3 months post-RFA and shrank to pre-ablation dimensions by 6 months post-RFA. SUVmax was more reliable than the size measurements by CT in the first 6 months after RFA, and PET/CT at 6 months post-RFA may be more appropriate for the assessment of FDG accumulation than that at 3 months post-RFA

    Practical method for determination of air kerma by use of an ionization chamber toward construction of a secondary X-ray field to be used in clinical examination rooms

    Get PDF
    We propose a new practical method for the construction of an accurate secondary X-ray field using medical diagnostic X-ray equipment. For accurate measurement of the air kerma of an X-ray field, it is important to reduce and evaluate the contamination rate of scattered X-rays. To determine the rate quantitatively, we performed the following studies. First, we developed a shield box in which an ionization chamber could be set at an inner of the box to prevent detection of the X-rays scattered from the air. In addition, we made collimator plates which were placed near the X-ray source for estimation of the contamination rate by scattered X-rays from the movable diaphragm which is a component of the X-ray equipment. Then, we measured the exposure dose while changing the collimator plates, which had diameters of 25–90 mmϕ. The ideal value of the exposure dose was derived mathematically by extrapolation to 0 mmϕ. Tube voltages ranged from 40 to 130 kV. Under these irradiation conditions, we analyzed the contamination rate by the scattered X-rays. We found that the contamination rates were less than 1.7 and 2.3 %, caused by air and the movable diaphragm, respectively. The extrapolated value of the exposure dose has been determined to have an uncertainty of 0.7 %. The ionization chamber used in this study was calibrated with an accuracy of 5 %. Using this kind of ionization chamber, we can construct a secondary X-ray field with an uncertainty of 5 %