415 research outputs found

    Slowed response to peripheral visual stimuli during strenuous exercise

    Get PDF
    Recently, we proposed that strenuous exercise impairs peripheral visual perception because visual responses to peripheral visual stimuli were slowed during strenuous exercise. However, this proposal was challenged because strenuous exercise is also likely to affect the brain network underlying motor responses. The purpose of the current study was to resolve this issue. Fourteen participants performed a visual reaction-time (RT) task at rest and while exercising at 50% (moderate) and 75% (strenuous) peak oxygen uptake. Visual stimuli were randomly presented at different distances from fixation in two task conditions: the Central condition (2° or 5° from fixation) and the Peripheral condition (30° or 50° from fixation). We defined premotor time as the time between stimulus onset and the motor response, as determined using electromyographic recordings. In the Central condition, premotor time did not change during moderate (167 ± 19 ms) and strenuous (168 ± 24 ms) exercise from that at rest (164 ± 17 ms). In the Peripheral condition, premotor time significantly increased during moderate (181 ± 18 ms, P < 0.05) and strenuous exercise (189 ± 23 ms, P < 0.001) from that at rest (173 ± 17 ms). These results suggest that increases in Premotor Time to the peripheral visual stimuli did not result from an impaired motor-response network, but rather from impaired peripheral visual perception. We conclude that slowed response to peripheral visual stimuli during strenuous exercise primarily results from impaired visual perception of the periphery

    Intramesocolic Diverticular Perforation of the Sigmoid Colon Diagnosed by Detecting Air Collection in Anterior Pararenal Space on Computed Tomography: Report of a Case

    Get PDF
    A 64-year-old woman was admitted to our hospital with lower abdominal pain. Routine laboratory values were unremarkable except for the white blood cell count (15,000/micro litter) and the C-reactive protein (CRP) value (22.5 mg/dl). A Computed tomography (CT) scan revealed air collection in the middle of the anterior pararenal space. One day later, CT revealed air collection in the anterior pararenal space spread to the right side and abscess in the sigmoid mesentery. Because an intramesocolic perforation of the sigmoid colon was suspected, an emergency operation was performed. Abscess formation was recognized in the sigmoid mesentery, and sigmoidectomy including the contaminated mesentery and Hartmann.s procedure were performed. The perforation was 3 cm in diameter, and some diverticula were present in the vicinity of the perforated site. The specimen microscopically revealed perforation at the edge of the diverticulum in association with sudden disruption of the proper muscle layer. Based on pathological findings, intramesocolic diverticular perforation of the sigmoid colon was diagnosed. The present case is a very rare condition. However, it was possible to make a diagnosis preoperatively by detecting air collection in the anterior pararenal space on CT scan. If a sigmoid perforation occurs between the leaves of the mesocolon, air extends into the root of the sigmoid mesocolon and within the anterior pararenal space

    A novel superior factor widely controlling the rice grain quality

    Get PDF
    Synthesis of storage starch and protein accumulation is the main action of endosperm organogenesis in term of the economic importance of rice. This event is strongly disturbed by abiotic stresses such as high temperature; thus, the upcoming global warming will cause a crisis with a great impact on food production^1,2^. The enzymes for the protein storage and starch synthesis pathway should work in concert to carry out the organogenesis of rice endosperm^3-5^, but the regulatory mechanism is largely unknown. Here we show that a novel regulatory factor, named OsCEO1, acts as the conductor of endosperm organogenesis during the rice grain filling stage. The physiological properties of _floury-endosperm-2_ (_flo2_) mutants showed many similarities to symptoms of grains developed under high-temperature conditions, suggesting important roles of the responsible gene in sensitivity to high-temperature stress. Our map-based cloning identified the responsible gene for the _flo2_ mutant, _OsCEO1_, which has no homology to any genes of known function. The _OsCEO1_ belongs to a novel conserved gene family and encodes a protein composed of 1,720 amino acid residues containing a TPR (tetratricopeptide repeat) motif, which is considered to mediate a protein-protein interaction. The yeast two-hybrid analysis raised an unknown protein showing homology to a late embryogenesis abundant protein and a putative basic helix-loop-helix protein as candidates for the direct interactor for _OsCEO1_, whereas no enzyme genes for the synthesis of storage substances were detected. The _flo2_ mutant exhibited reduced expression of several genes for putative regulatory proteins as well as many enzymes involved in storage starch and proteins. These results suggest that _OsCEO1_ is a superior conductor of the novel regulatory cascade of endosperm organogenesis and may have important roles in the response to high-temperature stress

    Low-level laser therapy for spinal cord injury in rats: effects of polarization

    Get PDF
    Abstract. The effects of laser polarization on the efficacy of near-infrared low-level laser therapy for spinal cord injury (SCI) are presented. Rat spinal cords were injured with a weight-drop device, and the lesion sites were directly irradiated with a linearly polarized 808-nm diode laser positioned either perpendicular or parallel to the spine immediately after the injury and daily for five consecutive days. Functional recovery was assessed daily by an open-field test. Regardless of the polarization direction, functional scores of SCI rats that were treated with the 808-nm laser irradiation were significantly higher than those of SCI alone group (Group 1) from day 5 after injury. The locomotive function of SCI rats irradiated parallel to the spinal column (Group 3) was significantly improved from day 10 after injury, compared to SCI rats treated with the linear polarization perpendicular to the spinal column (Group 2). There were no significant differences in ATP contents in the injured tissue among the three groups. We speculate that the higher efficacy with parallel irradiation is attributable to the deeper light penetration into tissue with anisotropic scattering

    Interferometer design of the KAGRA gravitational wave detector

    Get PDF
    KAGRA is a cryogenic interferometric gravitational-wave detector being constructed at the underground site of Kamioka mine in Gifu prefecture, Japan. We performed an optimization of the interferomter design, to achieve the best sensitivity and a stable operation, with boundary conditions of classical noises and under various practical constraints, such as the size of the tunnel or the mirror cooling capacity. Length and alignment sensing schemes for the robust control of the interferometer are developed. In this paper, we describe the detailed design of the KAGRA interferometer as well as the reasoning behind design choices

    Image-based evaluation of contraction–relaxation kinetics of human-induced pluripotent stem cell-derived cardiomyocytes: Correlation and complementarity with extracellular electrophysiology

    Get PDF
    AbstractIn this study, we used high-speed video microscopy with motion vector analysis to investigate the contractile characteristics of hiPS-CM monolayer, in addition to further characterizing the motion with extracellular field potential (FP), traction force and the Ca2+ transient. Results of our traction force microscopy demonstrated that the force development of hiPS-CMs correlated well with the cellular deformation detected by the video microscopy with motion vector analysis. In the presence of verapamil and isoproterenol, contractile motion of hiPS-CMs showed alteration in accordance with the changes in fluorescence peak of the Ca2+ transient, i.e., upstroke, decay, amplitude and full-width at half-maximum. Simultaneously recorded hiPS-CM motion and FP showed that there was a linear correlation between changes in the motion and field potential duration in response to verapamil (30–150nM), isoproterenol (0.1–10μM) and E-4031 (10–50nM). In addition, tetrodotoxin (3–30μM)-induced delay of sodium current was corresponded with the delay of the contraction onset of hiPS-CMs. These results indicate that the electrophysiological and functional behaviors of hiPS-CMs are quantitatively reflected in the contractile motion detected by this image-based technique. In the presence of 100nM E-4031, the occurrence of early after-depolarization-like negative deflection in FP was also detected in the hiPS-CM motion as a characteristic two-step relaxation pattern. These findings offer insights into the interpretation of the motion kinetics of the hiPS-CMs, and are relevant for understanding electrical and mechanical relationship in hiPS-CMs
    corecore