3 research outputs found

    Simultaneous Measurement of Ear Canal Movement, Electromyography of the Masseter Muscle and Occlusal Force for Earphone-Type Occlusal Force Estimation Device Development

    No full text
    We intend to develop earphone-type wearable devices to measure occlusal force by measuring ear canal movement using an ear sensor that we developed. The proposed device can measure occlusal force during eating. In this work, we simultaneously measured the ear canal movement (ear sensor value), the surface electromyography (EMG) of the masseter muscle and the occlusal force six times from five subjects as a basic study toward occlusal force meter development. Using the results, we investigated the correlation coefficient between the ear sensor value and the occlusal force, and the partial correlation coefficient between ear sensor values. Additionally, we investigated the average of the partial correlation coefficient and the absolute value of the average for each subject. The absolute value results indicated strong correlation, with correlation coefficients exceeding 0.9514 for all subjects. The subjects showed a lowest partial correlation coefficient of 0.6161 and a highest value of 0.8286. This was also indicative of correlation. We then estimated the occlusal force via a single regression analysis for each subject. Evaluation of the proposed method via the cross-validation method indicated that the root-mean-square error when comparing actual values with estimates for the five subjects ranged from 0.0338 to 0.0969

    Heatstroke risk informing system using wearable perspiration ratemeter on users undergoing physical exercise

    No full text
    Abstract We constructed an informing system to users for the heatstroke risk using a wearable perspiration ratemeter and the users’ thirst responses. The sweating ratemeter was constructed with a capacitive humidity sensor in the ventilated capsule. The timing point for informing heatstroke risk was decided to change from positive to negative on the second derivative of sweating curve. In addition, a wearable self-identification and -information system of thirst response was constructed with a smartphone. To evaluate the validity of wearable apparatus, we aimed to conduct human experiments of 16 healthy subjects with the step up and down physical exercises. The blood and urine samples of the subjects were collected before and after the 30-min physical exercise. The concentrations of TP, Alb, and RBC increased slightly with the exercise. In contrast, the concentrations of vasopressin in all subjects remarkably increased with the exercise. In almost subjects, they identified their thirst response until several min after the informing for heatstroke risk. In conclusion, the wearable ratemeter and self-information system of thirst response were suitable for informing system of heatstroke risk. The validity of timing point for informing heatstroke risk was confirmed with changes in the thirst response and concentrations of vasopressin in blood
    corecore