39 research outputs found

    Reproducibility of pulmonary magnetic resonance angiography in adults with muco-obstructive pulmonary disease

    Get PDF
    Background Recent studies support magnetic resonance angiography (MRA) as a diagnostic tool for pulmonary arterial disease. Purpose To determine MRA image quality and reproducibility, and the dependence of MRA image quality and reproducibility on disease severity in patients with chronic obstructive pulmonary disease (COPD) and cystic fibrosis (CF). Material and Methods Twenty patients with COPD (mean age 66.5 ± 8.9 years; FEV1% = 42.0 ± 13.3%) and 15 with CF (mean age 29.3 ± 9.3 years; FEV1% = 66.6 ± 15.8%) underwent morpho-functional chest magnetic resonance imaging (MRI) including time-resolved MRA twice one month apart (MRI1, MRI2), and COPD patients underwent non-contrast computed tomography (CT). Image quality was assessed visually using standardized subjective 5-point scales. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured by regions of interest. Disease severity was determined by spirometry, a well-evaluated chest MRI score, and by computational CT emphysema index (EI) for COPD. Results Subjective image quality was diagnostic for all MRA at MRI1 and MRI2 (mean score = 4.7 ± 0.6). CNR and SNR were 4 43.8 ± 8.7 and 50.5 ± 8.7, respectively. Neither image quality score nor CNR or SNR correlated with FEV1% or chest MRI score for COPD and CF (r = 0.239–0.248). CNR and SNR did not change from MRI1 to MRI2 (P = 0.434–0.995). Further, insignificant differences in CNR and SNR between MRA at MRI1 and MRI2 did not correlate with FEV1% nor chest MRI score in COPD and CF (r = −0.238–0.183), nor with EI in COPD (r = 0.100–0.111). Conclusion MRA achieved diagnostic quality in COPD and CF patients and was highly reproducible irrespective of disease severity. This supports MRA as a robust alternative to CT in patients with underlying muco-obstructive lung disease

    Parenchymal and Functional Lung Changes after Stereotactic Body Radiotherapy for Early-Stage Non-Small Cell Lung Cancer—Experiences from a Single Institution

    Get PDF
    IntroductionThis study aimed to evaluate parenchymal and functional lung changes following stereotactic body radiotherapy (SBRT) for early-stage non-small cell lung cancer (NSCLC) patients and to correlate radiological and functional findings with patient and treatment characteristics as well as survival.Materials and methodsSeventy patients with early-stage NSCLC treated with SBRT from 2004 to 2015 with more than 1 year of CT follow-up scans were analyzed. Incidence, morphology, severity of acute and late lung abnormalities as well as pulmonary function changes were evaluated and correlated with outcome.ResultsMedian follow-up time was 32.2 months with 2-year overall survival (OS) of 83% and local progression-free survival of 88%, respectively. Regarding parenchymal changes, most patients only developed mild to moderate CT abnormalities. Mean ipsilateral lung dose (MLD) in biological effective dose and planning target volume size were significantly associated with maximum severity score of parenchymal changes (p = 0.014, p < 0.001). Furthermore, both maximum severity score and MLD were significantly connected with OS in univariate analysis (p = 0.043, p = 0.025). For functional lung changes, we detected significantly reduced total lung capacity, forced expiratory volume in 1 s, and forced vital capacity (FVC) parameters after SBRT (p ≤ 0.001). Multivariate analyses revealed SBRT with an MLD ≥ 9.72 Gy and FVC reduction ≥0.54 L as independent prognostic factors for inferior OS (p = 0.029, p = 0.004).ConclusionSBRT was generally tolerated well with only mild toxicity. For evaluating the possible prognostic impact of MLD and FVC reduction on survival detected in this analysis, larger prospective studies are truly needed

    cOOpD: Reformulating COPD classification on chest CT scans as anomaly detection using contrastive representations

    Full text link
    Classification of heterogeneous diseases is challenging due to their complexity, variability of symptoms and imaging findings. Chronic Obstructive Pulmonary Disease (COPD) is a prime example, being underdiagnosed despite being the third leading cause of death. Its sparse, diffuse and heterogeneous appearance on computed tomography challenges supervised binary classification. We reformulate COPD binary classification as an anomaly detection task, proposing cOOpD: heterogeneous pathological regions are detected as Out-of-Distribution (OOD) from normal homogeneous lung regions. To this end, we learn representations of unlabeled lung regions employing a self-supervised contrastive pretext model, potentially capturing specific characteristics of diseased and healthy unlabeled regions. A generative model then learns the distribution of healthy representations and identifies abnormalities (stemming from COPD) as deviations. Patient-level scores are obtained by aggregating region OOD scores. We show that cOOpD achieves the best performance on two public datasets, with an increase of 8.2% and 7.7% in terms of AUROC compared to the previous supervised state-of-the-art. Additionally, cOOpD yields well-interpretable spatial anomaly maps and patient-level scores which we show to be of additional value in identifying individuals in the early stage of progression. Experiments in artificially designed real-world prevalence settings further support that anomaly detection is a powerful way of tackling COPD classification

    Design and application of an MR reference phantom for multicentre lung imaging trials

    Get PDF
    Introduction As there is an increasing number of multicentre lung imaging studies with MRI in patients, dedicated reference phantoms are required to allow for the assessment and comparison of image quality in multi-vendor and multi-centre environments. However, appropriate phantoms for this purpose are so far not available commercially. It was therefore the purpose of this project to design and apply a cost-effective and simple to use reference phantom which addresses the specific requirements for imaging the lungs with MRI. Methods The phantom was designed to simulate 4 compartments (lung, blood, muscle and fat) which reflect the specific conditions in proton-MRI of the chest. Multiple phantom instances were produced and measured at 15 sites using a contemporary proton-MRI protocol designed for an in vivo COPD study at intervals over the course of the study. Measures of signal- and contrast-to-noise ratio, as well as structure and edge depiction were extracted from conventionally acquired images using software written for this purpose. Results For the signal to noise ratio, low intra-scanner variability was found with 4.5% in the lung compartment, 4.0% for blood, 3.3% for muscle and 3.7% for fat. The inter-scanner variability was substantially higher, with 41%, 32%, 27% and 32% for the same order of compartments. In addition, measures of structure and edge depiction were found to both vary significantly among several scanner types and among scanners of the same model which were equipped with different gradient systems. Conclusion The described reference phantom reproducibly quantified image quality aspects and detected substantial inter-scanner variability in a typical pulmonary multicentre proton MRI study, while variability was greater in lung tissue compared to other tissue types. Accordingly, appropriate reference phantoms can help to detect bias in multicentre in vivo study results and could also be used to harmonize equipment or data

    Self-expanding Y stents in the treatment of central airway stenosis: a retrospective analysis

    No full text
    Background: Central airway obstruction (CAO) is a life-threatening situation. Stent insertion re-establishes patency of the central airways. Self-expanding metallic Y stents have been available since 2005, widening the spectrum of interventional bronchoscopic techniques. Methods: Retrospective analysis of all patients treated for CAO with a self-expanding metallic Y stent at the Thoraxklinik Heidelberg between May 2005 and January 2009. Results: A total of 43 patients aged 26–81 had a metallic Y stent inserted endoscopically for the treatment of CAO; 39 of these patients (90.7%) had CAO due to malignant disease, four patients (9.3%) due to benign disease. In all 43 patients, the Y stent was deployed without any complications. A longitudinal follow up was possible in 32 of the 43 patients. The stents remained in situ for an average of 107.1 days (range 1–640 days). In 29 patients with malignant CAO the stenosis was successfully overcome with a Y stent; 11 of these patients died within 6 weeks following stent insertion. On follow up the remaining 18 patients showed immediate improvement of dyspnoea. Eight out of the 18 patients (44.4%) tolerated the stent without problems, two (11.1%) required further stenting, six (33.3%) had complications such as increased secretions, cough, dyspnoea or granulation tissue formation. The stent was removed in one patient (5.6%) due to increased secretions, and in another (5.6%) as the stent was no longer required due to successful tumour-specific therapy. Conclusion: Placement of Y stents in symptomatic CAO allows for quick relief of symptoms. Severe complications are rare. Stent removal is possible after successful treatment of the primary tumour. However, the prognostic indicator for survival is the underlying malignancy

    Rapid 3D in vivo 1H human lung respiratory imaging at 1.5 T using ultra-fast balanced steady-state free precession.

    No full text
    PURPOSE To introduce a reproducible, nonenhanced 1H MRI method for rapid in vivo functional assessment of the whole lung at 1.5 Tesla (T). METHODS At different respiratory volumes, the pulmonary signal of ultra-fast steady-state free precession (ufSSFP) follows an adapted sponge model, characterized by a respiratory index α. From the model, α reflects local ventilation-related information, is virtually independent from the lung density and thus from the inspiratory phase and breathing amplitude. Respiratory α-mapping is evaluated for healthy volunteers and patients with obstructive lung disease from a set of five consecutive 3D ultra-fast steady-state free precession (ufSSFP) scans performed in breath-hold and at different inspiratory volumes. For the patients, α-maps were compared with CT, dynamic contrast-enhanced MRI (DCE-MRI), and Fourier decomposition (FD). RESULTS In healthy volunteers, respiratory α-maps showed good reproducibility and were homogeneous on iso-gravitational planes, but showed a gravity-dependent respiratory gradient. In patients with obstructive pulmonary disease, the functional impairment observed in respiratory α-maps was associated with emphysematous regions present on CT images, perfusion defects observable on DCE-MRI, and impairments visualized on FD ventilation and perfusion maps. CONCLUSION Respiratory α-mapping derived from multivolumetric ufSSFP provides insights into functional lung impairment and may serve as a reproducible and normative measure for clinical studies. Magn Reson Med, 2016. © 2016 International Society for Magnetic Resonance in Medicine

    Comparison of magnetic resonance imaging of inhaled SF6 with respiratory gas analysis

    No full text
    Magnetic resonance imaging of inhaled fluorinated inert gases ((19)F-MRI) such as sulfur hexafluoride (SF(6)) allows for analysis of ventilated air spaces. In this study, the possibility of using this technique to image lung function was assessed. For this, (19)F-MRI of inhaled SF(6) was compared with respiratory gas analysis, which is a global but reliable measure of alveolar gas fraction. Five anesthetized pigs underwent multiple-breath wash-in procedures with a gas mixture of 70% SF(6) and 30% oxygen. Two-dimensional (19)F-MRI and end-expiratory gas fraction analysis were performed after 4 to 24 inhaled breaths. Signal intensity of (19)F-MRI and end-expiratory SF(6) fraction were evaluated with respect to linear correlation and reproducibility. Time constants were estimated by both MRI and respiratory gas analysis data and compared for agreement. A good linear correlation between signal intensity and end-expiratory gas fraction was found (correlation coefficient 0.99+/-0.01). The data were reproducible (standard error of signal intensity 8% vs. that of gas fraction 5%) and the comparison of time constants yielded a sufficient agreement. According to the good linear correlation and the acceptable reproducibility, we suggest the (19)F-MRI to be a valuable tool for quantification of intrapulmonary SF(6) and hence lung function

    Ventilation-perfusion ratio in perflubron during partial liquid ventilation

    No full text
    BACKGROUND: Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake by ventilation and delivery by perfusion, to quantify the ventilation-perfusion ratio (Va/Q) of a lung region: The mixed venous blood and the inspiratory oxygen fraction, which are equal for all lung regions, are measured. In addition, the local expiratory oxygen fraction and the end capillary oxygen content, both of which may differ between the lung regions, are calculated using the fMRI-detected Pao(2). We investigated this approach by numerical simulations and applied it to quantify local Va/Q in the perfluorocarbons during partial liquid ventilation. METHODS: Numerical simulations were performed to analyze the sensitivity of the Va/Q calculation and to compare this approach with another one proposed by Rizi et al. in 2004 (Magn Reson Med 2004;52:65-72). Experimentally, the method was used during partial liquid ventilation in 7 anesthetized pigs. The Pao(2) distribution in intraalveolar perflubron was measured by fluorine-19 MRI. Respiratory gas fractions together with arterial and mixed venous blood samples were taken to quantify oxygen partial pressure and content. Using the Fick principle, the local Va/Q was estimated. The impact of gravity (nondependent versus dependent) of perflubron dose (10 vs 20 mL/kg body weight) and of inspired oxygen fraction (Fio(2)) (0.4-1.0) on Va/Q was examined. RESULTS: In numerical simulations, the Fick principle proved to be appropriate over the Va/Q range from 0.02 to 2.5. Va/Q values were in acceptable agreement with the method published by Rizi et al. In the experimental setting, low mean Va/Q values were found in perflubron (confidence interval [CI] 0.08-0.29 with 20 mL/kg perflubron). At this dose, Va/Q in the nondependent lung was higher (CI 0.18-0.39) than in the dependent lung regions (CI 0.06-0.16; P = 0.006; Student t test). Differences depending on Fio(2) or perflubron dose were, however, small. CONCLUSION: The results show that derivation of Va/Q from local Po(2) measurements using fMRI in perflubron is feasible. The low detected Va/Q suggests that oxygen transport into the perflubron-filled alveolar space is significantly restrained
    corecore