54 research outputs found

    Assessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography – a phantom and clinical study

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes.</p> <p>Design</p> <p>Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated.</p> <p>Results</p> <p>Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 ± 1 ml, variation range +4 to -4 ml) than MSCT software (mean difference 6 ± 5 ml; variation range +22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference -23 ± 40 ml, variation between +93 and -138 ml).</p> <p>Conclusion</p> <p>Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.</p

    Reduction in downstream test utilization following introduction of coronary computed tomography in a cardiology practice

    Get PDF
    To compare utilization of non-invasive ischemic testing, invasive coronary angiography (ICA), and percutaneous coronary intervention (PCI) procedures before and after introduction of 64-slice multi-detector row coronary computed tomographic angiography (CCTA) in a large urban primary and consultative cardiology practice. We utilized a review of electronic medical records (NotesMD®) and the electronic practice management system (Megawest®) encompassing a 4-year period from 2004 to 2007 to determine the number of exercise treadmill (TME), supine bicycle exercise echocardiography (SBE), single photon emission computed tomography (SPECT) myocardial perfusion stress imaging (MPI), coronary calcium score (CCS), CCTA, ICA, and PCI procedures performed annually. Test utilization in the 2 years prior to and 2 years following availability of CCTA were compared. Over the 4-year period reviewed, the annual utilization of ICA decreased 45% (2,083 procedures in 2004 vs. 1,150 procedures in 2007, P < 0.01) and the percentage of ICA cases requiring PCI increased (19% in 2004 vs. 28% in 2007, P < 0.001). SPECT MPI decreased 19% (3,223 in 2004 vs. 2,614 in 2007 P < 0.02) and exercise stress treadmill testing decreased 49% (471 in 2004 vs. 241 in 2007 P < 0.02). Over the same period, there were no significant changes in measures of practice volume (office and hospital) or the annual incidence of PCI (405 cases in 2004 vs. 326 cases in 2007) but a higher percentage of patients with significant disease undergoing PCI 19% in 2004 vs. 29% in 2007 P < 0.01. Implementation of CCTA resulted in a significant decrease in ICA and a corresponding significant increase in the percentage of ICA cases requiring PCI, indicating that CCTA resulted in more accurate referral for ICA. The reduction in unnecessary ICA is associated with avoidance of potential morbidity and mortality associated with invasive diagnostic testing, reduction of downstream SPECT MPI and TME as well as substantial savings in health care dollars

    The role of multi-slice computed tomography in stable angina management: a current perspective

    Get PDF
    Contrast-enhanced CT coronary angiography (CTCA) has evolved as a reliable alternative imaging modality technique and may be the preferred initial diagnostic test in patients with stable angina with intermediate pre-test probability of CAD. However, because CTCA is moderately predictive for indicating the functional significance of a lesion, the combination of anatomic and functional imaging will become increasingly important. The technology will continue to improve with better spatial and temporal resolution at low radiation exposure, and CTCA may eventually replace invasive coronary angiography. The establishment of the precise role of CTCA in the diagnosis and management of patients with stable angina requires high-quality randomised study designs with clinical outcomes as a primary outcome

    Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR

    Get PDF
    Objectives To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. Methods Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced- steady state free precession) SAX sequence for MR, and evaluated using dedicated software. Results CT and MR images showed good agreement: LV EF (Ejection Fraction) (52±14% for CT vs. 52±14% for MR; r0 0.73; p>0.05); RV EF (47±12% for CT vs. 47±12% for MR; r00.74; p>0.05); LV EDV (End Diastolic Volume) (74± 21 ml/m 2 for CT vs. 76±25 ml/m 2 for MR; r00.59; p>0.05); RV EDV (84±25 ml/m 2 for CT vs. 80±23 ml/m 2 for MR; r0 0.58; p>0.05); LV ESV (End Systolic Volume)(37±19 ml/m 2 for CT vs. 38±23 ml/m 2 for MR; r00.76; p>0.05); RV ESV (46±21 ml/m 2 for CT vs. 43±18 ml/m 2 for MR; r00.70; p>0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. Conclusions Cardiac CT provides accurate and reproducible LVand RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. Key Points • Cardiac-CT is able to provide Left and Right Ventricular function. • Cardiac-CT is accurate as MR for LV and RV volume assessment. • Cardiac-CT can provide accurate evaluation of coronary arteries and LV and RV function

    Asymptomatic melanoma of the superior cavo-atrial junction: The challenge of imaging

    No full text
    Metastatic lesions in the superior vena cava and the right atrium are difficult to diagnose: in computed tomography (CT), they are easily misinterpreted as artifacts, and the same region may be difficult to access using echocardiography. We present a case of asymptomatic metastasis of a malignant melanoma which was overlooked initially due to deficiencies in imaging. Using 18F-fluorodeoxyglucose positron emission tomography-CT, the metastasis was clearly identified and finally treated successfully. We discuss the diagnostic value of the various imaging modalities for intracardiac masses

    The UL97 gene product of human cytomegalovirus is an early-late protein with a nuclear localization but is not a nucleoside kinase.

    No full text
    The temporal expression of the UL97 gene product during human cytomegalovirus (HCMV) infection of human foreskin fibroblasts (HFF) and subcellular localization of this protein were analyzed by using a polyclonal antiserum raised against a truncated UL97 protein of 47 kDa. The UL97 protein was detectable 16 h after infection by Western blot (immunoblot) analysis. Since only reduced UL97 expression occurred in the presence of two inhibitors of DNA replication, phosphonoacetic acid and ganciclovir, we conclude that UL97 is an early-late gene, requiring DNA replication for maximum expression. By indirect immunofluorescence, the protein could be visualized in the nuclei of virus-infected HFF 22 h after infection. Nuclear localization of the UL97 protein was also detected in thymidine kinase-deficient 143B cells infected with a recombinant vaccinia virus containing the entire UL97 open reading frame (ORF), as well as in HFF transiently expressing the entire UL97 ORF under the control of HCMV major immediate-early promoter. However, transiently expressed 5'-terminal deletion mutants of the UL97 ORF in addition showed a cytoplasmic localization of the UL97 protein, confirming the presence of a nuclear localization site in the N-terminal region of the protein. Our high-pressure liquid chromatography analyses confirmed the ganciclovir phosphorylation by the UL97 protein, but no specific phosphorylation of natural nucleosides was observed, indicating that the UL97 protein is not a nucleoside kinase. During plaque purification of recombinant UL97-deficient HCMV, this virus was growth defective; hence, we presume that UL97 may be essential for the viral life cycle

    Clinical use of multislice spiral computed tomography in 210 highly preselected patients: experience with 4 and 16 slice technology

    No full text
    Objective: To report an initial experience with multislice spiral computed tomography (MSCT) coronary imaging, as well as differences in diagnostic accuracy between 4 slice and 16 slice MSCT technology. Methods and results: 210 patients underwent MSCT coronary angiography (4 slices, n  =  120; 16 slices, n  =  90; suspicion of coronary artery disease, n  =  158; suspicion of restenosis, n  =  52). Recommendations for further diagnostic tests were based on the MSCT results. Patients were interviewed by telephone after a mean (SD) of 449 (169) days to evaluate their further clinical course. MSCT detected significant lesions in 90 of 210 (43%) patients and invasive coronary angiography (ICA) was recommended. MSCT excluded significant lesions in 120 of 210 (57%) patients. ICA was actually performed in 44 of 210 (21%) patients (corresponding results, 27 of 44 (61%); false positive, 11 of 44 (25%); false negative, 6 of 44 (14%)). No significant differences were found between 4 and 16 slice imaging. No major cardiac event occurred during follow up. Conclusions: MSCT was found to be useful to evaluate the need for invasive diagnostic procedures. However, the false negative results underline that further improvements of image quality are required before MSCT can replace ICA in carefully selected patients
    corecore